{"product_id":"1769-ov16-24vdc-discrete-output-module-allen-bradley-compactlogix","title":"1769-OV16 24VDC Discrete Output Module Allen-Bradley CompactLogix","description":"\u003ch3\u003eEngineering Overview \u0026amp; System Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e**1769-OV16**\u003c\/span\u003e is a high-density discrete output module designed for the \u003cspan style=\"color: #0056b3;\"\u003e**Compact I\/O**\u003c\/span\u003e and \u003cspan style=\"color: #0056b3;\"\u003e**\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/allen-bradley-1769-compactlogix\"\u003eCompactLogix\u003c\/a\u003e**\u003c\/span\u003e controller platforms by \u003cspan style=\"color: #0056b3;\"\u003e**Allen-Bradley**\u003c\/span\u003e (Rockwell Automation). Built with sixteen independent sink-wiring output channels, the \u003cspan style=\"color: #0056b3;\"\u003e**1769-OV16**\u003c\/span\u003e efficiently manages low-voltage DC actuators, solenoid valves, and indicator arrays within compact industrial control panels.\u003c\/p\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Specification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \u0026amp; Brand\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series \u0026amp; Type\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e**Compact I\/O**\u003c\/span\u003e 24VDC Discrete Sinking Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Catalog Number\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e**1769-OV16**\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels grouped into a single output bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC (Nominal 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current Rating\u003c\/td\u003e\n\u003ctd\u003e0.5 A @ 60°C (140°F); up to 1.0 A @ 30°C (86°F) per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Draw\u003c\/td\u003e\n\u003ctd\u003e200 mA @ 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Switching Speed\u003c\/td\u003e\n\u003ctd\u003e0.1 ms ON-state delay; 1.0 ms OFF-state delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Modes \u0026amp; System Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configuration:\u003c\/strong\u003e Sinking output layout designed to interface with sourcing field loads requiring active low-side switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Interoperability:\u003c\/strong\u003e Fully compatible with \u003cspan style=\"color: #0056b3;\"\u003e**CompactLogix**\u003c\/span\u003e and MicroLogix 1500 controllers as local or expansion I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Handling Capacity:\u003c\/strong\u003e Withstands transient surge currents up to 2.0 A for 10 ms, repeatable every 2 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Distance Limit:\u003c\/strong\u003e Must be installed within 8 modules of a system power supply, or supplemented using compatible units like the 1769-PB2 or 1769-PA2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines \u0026amp; Commissioning Convenience\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the system backplane before mounting the single-slot module to a DIN rail or direct panel backplate.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring from beneath the unit directly into the front-accessible removable terminal block featuring a finger-safe protective cover.\u003c\/li\u003e\n\u003cli\u003eUtilize solid copper wire (22 to 14 AWG) or stranded wire (22 to 16 AWG) rated for 90°C thermal endurance.\u003c\/li\u003e\n\u003cli\u003eVerify terminal block seating and check LED status indicators before restoring operational 24VDC field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities \u0026amp; Industrial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Monitoring:\u003c\/strong\u003e Maintains a low OFF-state leakage current threshold of 1.0 mA max at 26.4 VDC to prevent ghost-state actuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e Optimized for dense control enclosures with a maximum heat dissipation rate of 2.06 Watts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Applications:\u003c\/strong\u003e Deployed in high-speed packaging machinery, automated sorting conveyors, assembly line pneumatic valve manifolds, and material handling controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eAutomation engineers integrating the \u003cspan style=\"color: #0056b3;\"\u003e**1769-OV16**\u003c\/span\u003e frequently encounter thermal derating issues when enclosing multiple high-current loads in sealed cabinets without forced ventilation. During a recent high-duty packaging machine retrofit, our engineering team resolved intermittent over-temperature channel dropouts by spacing high-draw pneumatic solenoids across separate output groups and verifying that ambient enclosure temperatures remained strictly below 60°C.\u003c\/p\u003e\n\u003ch3\u003eLogistics, Packaging \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Inclusion:\u003c\/strong\u003e 1x \u003cspan style=\"color: #0056b3;\"\u003e**1769-OV16**\u003c\/span\u003e Compact I\/O 16-Point Sinking Output Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Schedule:\u003c\/strong\u003e Fast 24 to 48-hour order processing and dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Couriers:\u003c\/strong\u003e Secure worldwide delivery handled via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Assurance:\u003c\/strong\u003e Backed by a comprehensive 12-month operational warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ) \u0026amp; Buying Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum continuous current per module when operating at an ambient temperature of 30°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports up to 1.0 Amp per point, achieving a maximum continuous current capacity of 8.0 Amps across the entire module at 30°C (86°F).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1769-OV16 module be used with sourcing-type field actuators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this module utilizes a sink-wiring configuration and is specifically designed to control loads that require active low-side switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What action should I take if my I\/O bank exceeds the 8-module power supply distance rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: You must insert an auxiliary system power supply, such as the 1769-PB2 or 1769-PA2, to re-energize the expansion backplane bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What wire sizes are approved for terminating field devices on the removable terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: You can use solid copper wire sized 22 to 14 AWG or stranded copper wire sized 22 to 16 AWG rated for 90°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Buying Guide: When should I opt for a sinking output module instead of a sourcing module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Choose a sinking module like the \u003cspan style=\"color: #0056b3;\"\u003e**1769-OV16**\u003c\/span\u003e when your plant schematic or connected DC actuators (such as specific electronic relays and valve coils) require the controller to switch the negative DC common line.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013821456566,"sku":"1769-OV16","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1769-OV16_bd498867-1e45-4890-b631-d5c6db313cfd.jpg?v=1788944881","url":"https:\/\/www.plcsparehub.com\/products\/1769-ov16-24vdc-discrete-output-module-allen-bradley-compactlogix","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}