{"product_id":"1769-ascii-allen-bradley-2-channel-rs232-rs485-communication-module","title":"1769-ASCII Allen-Bradley 2-Channel RS232 RS485 Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eAllen-Bradley 1769-ASCII\u003c\/span\u003e\u003c\/strong\u003e is a two-channel ASCII communication module. It connects CompactLogix and MicroLogix 1500 controllers with serial ASCII devices.\u003c\/p\u003e\n\u003cp\u003eThe module supports barcode readers, serial instruments, scanners, and other ASCII-compatible equipment. It provides two independently configurable serial ports for data exchange.\u003c\/p\u003e\n\u003cp\u003eEach port supports different communication settings. This allows the controller to communicate with separate serial devices simultaneously.\u003c\/p\u003e\n\u003cp\u003eThe module supports RS-232, RS-422, and RS-485 communication modes. Its isolated serial interfaces help separate field communication from the controller backplane.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e1769-ASCII\u003c\/strong\u003e receives power directly from the 1769 system backplane. It does not require a separate external power supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e1769-ASCII\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompactLogix 1769\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecialty Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII Serial Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × DB-9 male connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-422, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex and half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Handshaking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTS\/CTS enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Words\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Words\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransaction ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e425 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40–85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g at 10–500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Operating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 34 × 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries A and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC \/ GTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10612598314239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Note:\u003c\/strong\u003e The supplied specifications contain conflicting power and current values. The 425 mA at 5 V DC rating corresponds to approximately 2.13 W. The 7.5 W and 33.6 W figures require verification against the applicable hardware documentation. Confirm electrical ratings before system design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Features and Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Serial Channels:\u003c\/strong\u003e Each port supports independent communication configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e The module exchanges data through ASCII-based serial protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Selection:\u003c\/strong\u003e RS-232, RS-422, and RS-485 support different field wiring requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Handshaking:\u003c\/strong\u003e RTS\/CTS controls serial data transmission between compatible devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransaction Identification:\u003c\/strong\u003e Transaction IDs range from 0 to 255.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e Status information identifies transmission and reception problems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Input Signal Levels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLogic 0: +3 to +25 V DC relative to signal ground.\u003c\/li\u003e\n\u003cli\u003eLogic 1: -3 to -25 V DC relative to signal ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Status Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTX FIFO overflow\u003c\/li\u003e\n\u003cli\u003eRX FIFO overflow\u003c\/li\u003e\n\u003cli\u003eRX parity error\u003c\/li\u003e\n\u003cli\u003eHandshake error\u003c\/li\u003e\n\u003cli\u003eNew data flag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese indicators help engineers identify communication errors during commissioning and troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Specification Note:\u003c\/strong\u003e The module provides serial data communication. Measurement range, sensor sensitivity, linearity, and measurement resolution do not apply. Baud rate and detailed timing limits require confirmation from the applicable Rockwell Automation documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1769-ASCII\u003c\/strong\u003e mounts directly onto a compatible Compact I\/O assembly. It supports DIN rail and panel mounting arrangements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect system power before installation.\u003c\/li\u003e\n\u003cli\u003eVerify the controller and chassis compatibility.\u003c\/li\u003e\n\u003cli\u003eCheck the available backplane power capacity.\u003c\/li\u003e\n\u003cli\u003eInstall the module within four module positions of the power supply.\u003c\/li\u003e\n\u003cli\u003eSecure the module to the DIN rail or mounting panel.\u003c\/li\u003e\n\u003cli\u003eConnect serial devices through the DB-9 connectors.\u003c\/li\u003e\n\u003cli\u003eUse suitable shielded communication cable, such as Belden 8761 where applicable.\u003c\/li\u003e\n\u003cli\u003eCheck the communication interface and wiring configuration.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify module operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse the correct RS-232, RS-422, or RS-485 wiring arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck signal polarity and signal ground connections.\u003c\/li\u003e\n\u003cli\u003eSeparate serial communication cables from high-voltage power cables.\u003c\/li\u003e\n\u003cli\u003eGround cable shields according to the system grounding design.\u003c\/li\u003e\n\u003cli\u003eVerify RTS\/CTS wiring when hardware handshaking is enabled.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume identical pin assignments across different serial interfaces. Follow the device-specific wiring diagrams.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Electrical Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module operates within specified industrial environmental conditions. Proper installation helps maintain reliable serial communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: 0–60°C.\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40–85°C.\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5–95%, non-condensing.\u003c\/li\u003e\n\u003cli\u003eOperating vibration: 5 g at 10–500 Hz.\u003c\/li\u003e\n\u003cli\u003eOperating shock: 30 g.\u003c\/li\u003e\n\u003cli\u003eNon-operating shock: 50 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep the module within its specified operating conditions. Avoid condensation, excessive vibration, and unstable backplane connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information does not identify specific certification numbers or approval marks. Please confirm applicable certifications through the product nameplate and official Rockwell Automation documentation.\u003c\/p\u003e\n\u003cp\u003eFor projects requiring UL, CE, hazardous-location, or other regulatory approvals, verify the exact catalog number and applicable revision before purchase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Allen-Bradley 1769-ASCII ASCII Communication Module.\u003c\/li\u003e\n\u003cli\u003eStandard product packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional cables, controllers, power supplies, and configuration software are not included unless specified in the order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the Allen-Bradley 1769-ASCII?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e1769-ASCII\u003c\/strong\u003e connects CompactLogix and MicroLogix 1500 controllers with ASCII-compatible serial equipment. Common applications include barcode scanning and serial data acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can both serial ports communicate with different devices simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module provides two independently configurable communication channels. Each port can exchange data with a separate serial device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the 1769-ASCII require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module receives operating power from the 1769 backplane. Engineers must verify the available power budget before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should engineers check when a barcode reader cannot communicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the physical interface and wiring. Then verify baud rate, parity, data bits, and handshake settings. Check the module status information for parity errors and FIFO overflow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can the 1769-ASCII replace a standard Ethernet communication module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \u003cstrong\u003e1769-ASCII\u003c\/strong\u003e provides serial ASCII communication. It does not provide an Ethernet interface or native Ethernet protocol communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What is the difference between RS-232, RS-422, and RS-485?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRS-232 typically connects point-to-point devices. RS-422 supports differential signaling over longer cable distances. RS-485 supports differential multi-device communication. Select the interface according to the field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: What should buyers verify before ordering a 1769-ASCII?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the controller platform, module revision, serial interface, channel requirements, and backplane power capacity. Also check the required cable and connector arrangement. Provide your existing module label for compatibility verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Can a Series A module replace a Series B module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo not assume direct interchangeability. Check the hardware revision, controller firmware, and project configuration requirements. Confirm the replacement arrangement before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: What information helps diagnose intermittent serial communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the connected device model, serial settings, cable length, and error status. Check whether the problem affects one channel or both channels. This information helps identify wiring, configuration, or module-related faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: What should I provide when requesting a replacement module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete catalog number, series, existing module photograph, and controller model. Include the connected serial device and required communication interface. These details help reduce ordering errors. application.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013989064886,"sku":"1769-ASCII","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1769-ASCII_6e97e8e7-c3b8-4d53-b7b7-2b1e510e424d.jpg?v=1795059463","url":"https:\/\/www.plcsparehub.com\/products\/1769-ascii-allen-bradley-2-channel-rs232-rs485-communication-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}