{"product_id":"1756-a13-rockwell-automation-controllogix-chassis-plc-rack","title":"1756-A13 Rockwell Automation ControlLogix Chassis | PLC Rack","description":"\u003ch3\u003e\u003cstrong\u003eAllen-Bradley 1756-A13 | ControlLogix Chassis Engineering Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003e1756-A13\u003c\/strong\u003e\u003c\/span\u003e is a 13-slot ControlLogix chassis manufactured by Rockwell Automation under the Allen-Bradley brand. It provides a shared backplane for module communication and distributes power from the installed chassis power supply to compatible modules.\u003c\/p\u003e\n\u003cp\u003eUnlike a controller or I\/O module, this chassis provides the physical mounting structure and electrical interconnection for the automation system. Engineers can install compatible ControlLogix controllers, communication modules, and I\/O modules in available slots.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Module mounting, backplane communication, and power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Capacity:\u003c\/strong\u003e 13 module slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Orientation:\u003c\/strong\u003e Horizontal mounting only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method:\u003c\/strong\u003e Panel mounting through chassis mounting tabs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open-type chassis; install inside a suitable industrial cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Feature:\u003c\/strong\u003e Removal and Insertion Under Power (RIUP) support, subject to module-specific requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Mechanical and Electrical Reference\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1756-A13\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003e13-slot chassis with backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Tabs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e588 × 169 × 145 mm (23.15 × 6.65 × 5.71 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Cabinet Size (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e762 × 609 × 203 mm (30 × 24 × 8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e1.90 kg (4.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 1.2 VDC\u003c\/td\u003e\n\u003ctd\u003e1.5 A chassis maximum \/ 1.5 A per-slot maximum, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e4 A chassis maximum \/ 4 A per-slot maximum, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 5.1 VDC\u003c\/td\u003e\n\u003ctd\u003eSupplied data lists 15 A chassis maximum and 6 A per-slot maximum; verify against the applicable manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e2.8 A chassis maximum \/ 2.8 A per-slot maximum, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eSupplied sources list 5.4 W and 6.1 BTU\/hour; verify the applicable rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature, Series A\/B\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C, according to the supplied descriptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature, Series C\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e2 g at 10–500 Hz, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eOpen type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e10612598129284, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e32151704, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering clarification:\u003c\/strong\u003e Backplane current ratings describe available distribution capacity, not the chassis power supply's actual consumption. Select the power supply using the individual module loads and the manufacturer's chassis power budget.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Backplane Architecture and Slot Planning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe backplane forms the electrical communication path between compatible modules. It also distributes the required DC power rails throughout the chassis.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Position:\u003c\/strong\u003e Reserve a suitable slot for the selected ControlLogix controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Position:\u003c\/strong\u003e Allocate slots for required network and communication modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Allocation:\u003c\/strong\u003e Assign remaining slots according to digital, analog, specialty, and application requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Planning:\u003c\/strong\u003e Reserve capacity for future modules when the process design requires expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Slots:\u003c\/strong\u003e Use the specified 1756-N2 slot filler where required by the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e A machine-control rack may use one slot for a controller, two slots for communication modules, and several slots for digital and analog I\/O. Engineers must confirm the final slot allocation against the actual bill of materials.\u003c\/p\u003e\n\u003cp\u003eThe 13-slot capacity does not guarantee that every combination of modules will fit the electrical power budget. Check the required current on each backplane voltage rail before approving the layout.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Cabinet Installation and Grounding\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm Cabinet Clearance:\u003c\/strong\u003e Provide sufficient internal space for the chassis, wiring, ventilation, and maintenance access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Orientation:\u003c\/strong\u003e Install the chassis horizontally as required by the supplied product information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the Subpanel:\u003c\/strong\u003e Check mounting dimensions, panel rigidity, and access to the mounting tabs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure the Chassis:\u003c\/strong\u003e Fasten all required mounting points according to the installation manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Protective Grounding:\u003c\/strong\u003e Follow the manufacturer's grounding instructions and applicable electrical codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Compatible Modules:\u003c\/strong\u003e Verify catalog numbers, slot assignments, and installation requirements before insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Power Budget:\u003c\/strong\u003e Confirm that the selected power supply supports the complete module configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommission the Rack:\u003c\/strong\u003e Verify module recognition, communication status, and expected controller operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe supplied grounding information specifies 8 AWG copper wire for functional earth and 14 AWG copper wire for protective earth, with a minimum 90°C temperature rating. Confirm conductor requirements and terminal specifications against the applicable installation manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety note:\u003c\/strong\u003e RIUP support does not mean every module can be removed under every operating condition. Follow the specific module instructions and site electrical safety procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Compatibility and System Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Item\u003c\/th\u003e\n\u003cth\u003eEngineering Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Family\u003c\/td\u003e\n\u003ctd\u003eConfirm the selected controller supports the chassis and intended ControlLogix system architecture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Controller Generations\u003c\/td\u003e\n\u003ctd\u003eThe supplied description identifies Logix 5560, 5570, and 5580 families. Verify the exact controller catalog number and compatibility documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eCheck chassis compatibility and calculate the load across every required backplane voltage rail.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Modules\u003c\/td\u003e\n\u003ctd\u003eVerify module compatibility, slot requirements, and power consumption.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Modules\u003c\/td\u003e\n\u003ctd\u003eConfirm supported networks, firmware, and communication architecture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Chassis\u003c\/td\u003e\n\u003ctd\u003eCompare catalog number, series, dimensions, mounting orientation, and environmental requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Fillers\u003c\/td\u003e\n\u003ctd\u003eCheck the installation manual for the correct treatment of unused slots and required 1756-N2 fillers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement advice:\u003c\/strong\u003e Do not select a chassis solely by its 13-slot capacity. Compare the existing rack's series, controller family, power requirements, cabinet layout, and installed module list before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Suitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Lines:\u003c\/strong\u003e Provides a central mounting and backplane platform for controller and distributed I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Equipment:\u003c\/strong\u003e Supports control architectures for conveyors, filling machines, labeling systems, and automated packaging cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Accommodates compatible controller and communication modules used in conveyor and transfer systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Equipment:\u003c\/strong\u003e Houses compatible ControlLogix modules for process sequencing, interlocks, and field signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilities and Infrastructure:\u003c\/strong\u003e Supports compatible automation racks used for equipment monitoring and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Retrofit Projects:\u003c\/strong\u003e Provides a chassis replacement option when the existing system requires a verified compatible rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplication suitability depends on the installed controller, I\/O modules, network design, power supply, and environmental conditions. The chassis itself does not execute control logic or independently monitor field devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Fault Isolation and Maintenance Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003e1756-A13\u003c\/strong\u003e\u003c\/span\u003e provides the physical backplane and mounting structure for the installed automation modules. Engineers diagnose rack-related problems by examining module status, power conditions, controller faults, and backplane communication behavior.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003eRecommended Investigation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral modules fail to start\u003c\/td\u003e\n\u003ctd\u003eCheck the chassis power supply, module seating, backplane connections, and system fault records.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne module remains unavailable\u003c\/td\u003e\n\u003ctd\u003eInspect the affected slot, module status, compatibility, and module-specific diagnostic information.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent communication faults\u003c\/td\u003e\n\u003ctd\u003eReview controller logs, communication module status, power stability, and installation conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack expansion causes startup problems\u003c\/td\u003e\n\u003ctd\u003eRecalculate backplane loading and confirm the power supply supports the revised module configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeated faults after replacement\u003c\/td\u003e\n\u003ctd\u003eCompare the chassis series, module catalog numbers, slot assignments, and system configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e An engineer adds several I\/O modules to an existing rack. The system then reports module faults during startup. The engineer reviews the power budget for each backplane voltage rail and checks the power supply's capacity. This process helps distinguish power-loading problems from module configuration or communication faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance recommendation:\u003c\/strong\u003e Record the chassis catalog number, series, slot map, module list, and power budget in the maintenance documentation. These records improve fault isolation and reduce unnecessary module replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn field replacement projects, engineers often focus on slot count and overlook electrical loading. A 13-slot chassis may accommodate the planned modules physically, yet the power supply may not support their combined demand on every voltage rail.\u003c\/p\u003e\n\u003cp\u003eFor example, a retrofit may add analog input modules and communication hardware to an existing ControlLogix rack. The correct approach is to document each module's current requirements, calculate the load per voltage rail, and compare the totals with the approved chassis and power supply limits.\u003c\/p\u003e\n\u003cp\u003eEngineers should also confirm the chassis series before installing equipment in low-temperature environments. The supplied specifications list different lower operating limits for Series A\/B and Series C. Verify the actual nameplate and applicable manual before approving the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOur practical recommendation:\u003c\/strong\u003e Use the complete rack configuration—not slot count alone—to evaluate a replacement. This approach helps reduce commissioning delays, power-related faults, and compatibility risks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Packaging, Warranty, and Worldwide Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Allen-Bradley 1756-A13 ControlLogix 13-slot chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective shipping packaging appropriate to the confirmed order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Power supplies, controllers, modules, slot fillers, and other accessories are included only when specified in the quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty under the seller's confirmed terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Target:\u003c\/strong\u003e 24–48 hours after order confirmation, subject to stock availability and payment verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Options:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Orders:\u003c\/strong\u003e Delivery times depend on destination, customs clearance, and carrier operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Global PLC Spare HUB to confirm stock status, exact package contents, dispatch timing, shipping costs, and warranty coverage before placing an order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I determine whether the 1756-A13 provides enough electrical capacity for a fully populated rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eList every planned module and its current requirements for each backplane voltage rail. Add the loads separately, then compare the totals with the chassis limits and power supply ratings. Do not calculate capacity from the slot count alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should I inspect if a chassis replacement fits mechanically but the system configuration still fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the chassis series, controller compatibility, module catalog numbers, power supply configuration, and slot assignments. Review controller and module fault information before changing the project or replacing additional components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How should I choose between different 1756-A13 chassis series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the nameplate, operating temperature requirements, mechanical dimensions, and applicable manufacturer documentation. Series differences can affect environmental suitability, so confirm the exact catalog number before ordering a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the 1756-A13 suitable for an installation with frequent module maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied product information identifies RIUP support. However, engineers must check the specific module's removal requirements, electrical safety procedures, and process consequences before performing maintenance under power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should I provide when requesting a replacement chassis quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full catalog number, chassis series, installed controller model, power supply model, module list, operating temperature, and delivery destination. These details help the supplier review compatibility and provide more accurate pricing and shipping information.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Request Pricing and Compatibility Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNeed an \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003eAllen-Bradley 1756-A13 ControlLogix chassis\u003c\/strong\u003e\u003c\/span\u003e for a new rack or replacement project? Contact Global PLC Spare HUB for pricing and configuration review.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 1756-A13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 13-slot ControlLogix chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rockwell Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequest Information:\u003c\/strong\u003e Price, availability, compatibility, warranty, and delivery options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSend your existing rack configuration and required quantity to help our team assess the appropriate sourcing option.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67651543662774,"sku":"1756-A13","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1756-A13-1.jpg?v=1792122154","url":"https:\/\/www.plcsparehub.com\/products\/1756-a13-rockwell-automation-controllogix-chassis-plc-rack","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}