{"product_id":"1747-uic-allen-bradley-slc-500-interface-converter","title":"1747-UIC Allen-Bradley SLC 500 Interface Converter","description":"\u003ch3\u003e\u003cstrong\u003eAllen-Bradley 1747-UIC Engineering Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e1747-UIC\u003c\/strong\u003e\u003c\/span\u003e manufactured by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAllen-Bradley \/ Rockwell Automation\u003c\/strong\u003e\u003c\/span\u003e is a specialized \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eUSB to DH-485 interface converter\u003c\/strong\u003e\u003c\/span\u003e engineered within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSLC 500\u003c\/strong\u003e\u003c\/span\u003e product family. Designed to bridge modern computers with legacy automation assets, this portable adapter translates USB protocols into DH-485 communication streams at a standard 19,200 bits\/second baud rate while drawing operating power directly from the host USB port.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications \u0026amp; Operating Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Brand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eRockwell Automation\u003c\/strong\u003e\u003c\/span\u003e \/ \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e1747-UIC\u003c\/strong\u003e\u003c\/span\u003e \/ \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSLC 500 Series\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSB-to-DH-485 Communication Interface Converter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSB (12 Mbps transfer), RJ-45 DH-485, and RS-232 DB9 ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19.2 Kbps fixed communication transfer rate on DH-485 side\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBus-powered directly from connected computer's USB port (\u0026lt;100 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCircuit Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500V DC galvanic isolation between USB power and DH-485 common\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C to 60°C (32°F to 140°F); Net Dimensions: 109 x 50.6 x 31 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Industrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLegacy SLC 500 (5\/01, 5\/02, 5\/03) processor programming and online troubleshooting.\u003c\/li\u003e\n  \u003cli\u003eMicroLogix controller and PanelView operator terminal network configuration.\u003c\/li\u003e\n  \u003cli\u003ePlant floor commissioning and maintenance diagnostic laptop hookups.\u003c\/li\u003e\n  \u003cli\u003eOlder DH-485 multidrop network bridging during modernization assessments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eAdvanced Diagnostic \u0026amp; Isolation Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides robust 500V DC isolation between computer USB grounds and industrial DH-485 circuits, protecting laptops from electrical ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual DH-485 Ports:\u003c\/strong\u003e Features switch-selectable RJ-45 and RS-232 DB9 connection options to accommodate diverse legacy controller cabling configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus-Powered Simplicity:\u003c\/strong\u003e Eliminates external power supplies or bulky AC adapters, ensuring rapid plug-and-play connectivity on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommercial Terms \u0026amp; Global Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition \u0026amp; Assurance:\u003c\/strong\u003e 100% factory original hardware backed by a comprehensive \u003cstrong\u003e12-month warranty\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder Fulfillment:\u003c\/strong\u003e Rapid processing and dispatch within \u003cstrong\u003e24 to 48 hours\u003c\/strong\u003e of order verification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpress Freight Carriers:\u003c\/strong\u003e Expedited worldwide delivery supported via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eConnecting modern engineering laptops to legacy SLC 500 or PanelView hardware on the plant floor often presents severe communication hurdles and ground loop risks. Our engineering evaluation indicates that deploying the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e1747-UIC\u003c\/strong\u003e\u003c\/span\u003e converter solves these interface barriers securely. During an emergency service call at a legacy manufacturing plant, utilizing this USB-to-DH-485 adapter allowed our technicians to go online instantly with an older SLC 5\/03 processor without encountering driver dropouts or risking laptop USB port damage from high electrical common-mode voltages.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection \u0026amp; Purchasing Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify Controller Compatibility:\u003c\/strong\u003e Confirm your legacy target device utilizes the DH-485 communication protocol (such as SLC 5\/01 through 5\/03 or early PanelViews).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Preparation:\u003c\/strong\u003e Ensure you have the appropriate RJ-45 (1747-C13) or RS-232 connecting cables corresponding to your converter port selection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDriver Setup Advice:\u003c\/strong\u003e Verify RSLinx driver configurations match the 19.2 Kbps DH-485 network speed before attempting online processor connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the 1747-UIC interface converter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: It bridges modern USB-equipped computers to legacy Allen-Bradley controllers and operator interfaces running on the DH-485 communication network.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does the converter require an external power supply or wall transformer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No, the unit is entirely bus-powered through the connected computer's USB port, consuming less than 100 mA of operating current.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How does the converter protect programming laptops from industrial electrical surges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: It incorporates built-in 500V DC galvanic isolation between the USB power circuit and the DH-485 common reference, effectively preventing ground loop damage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: What physical connection ports are available on the DH-485 side of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: It provides two switch-selectable ports: an RJ-45 modular jack and an RS-232 DB9 serial connector.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What shipping carriers and delivery timelines apply to urgent replacement orders?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: We dispatch all in-stock converters within 24 to 48 hours utilizing priority international carriers including FedEx, UPS, and DHL to minimize downtime.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013898363062,"sku":"1747-UIC","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1747-UIC_7cbb94c1-7034-49b3-80c2-1732ab544331.jpg?v=1793170707","url":"https:\/\/www.plcsparehub.com\/products\/1747-uic-allen-bradley-slc-500-interface-converter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}