{"product_id":"1747-m13-allen-bradley-slc-500-memory-module-64kb-flash-storage","title":"1747-M13 Allen-Bradley SLC 500 Memory Module 64KB Flash Storage","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eAllen-Bradley 1747-M13\u003c\/span\u003e\u003c\/strong\u003e serves as a reliable non-volatile memory solution for the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 500\u003c\/span\u003e\u003c\/strong\u003e controller system. Engineers utilize this \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/strong\u003e module to back up program logic and data tables permanently. It preserves critical control routines during total battery drain or unexpected power outages.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/strong\u003e module features 64 kilobytes of high-density Flash memory. It mounts directly onto a compatible memory adapter for seamless hardware integration. System administrators rely on this component to eliminate program loss, reduce system downtime, and streamline automatic startup routines.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rockwell Automation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eAllen-Bradley\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 500\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #00**SEO Title Suggestions**\n\n* **SEO Title Option 1 (63 chars):**\n  Allen-Bradley 1747-M13 SLC 500 64K Flash Memory Module | Rockwell\n\n* **SEO Title Option 2 (64 chars):**\n  1747-M13 Allen-Bradley SLC 500 64KB Flash Memory Backup Module\n\n**SEO Meta Description (148 chars)**\nContact us today for a fast quote on the Allen-Bradley 1747-M13 SLC 500 64KB Flash Memory Module. 24-48h dispatch, full warranty, best prices!\n\n***\n\n\u0026lt;h3\u0026gt;\u0026lt;b\u0026gt;Product Overview\u0026lt;\/b\u0026gt;\u0026lt;\/h3\u0026gt;\n\u0026lt;p\u0026gt;The \u0026lt;b\u0026gt;\u0026lt;span style=\" color:\u003eAllen-Bradley\u003c\/span\u003e \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/b\u003e serves as a reliable 64KB flash memory module for \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 500\u003c\/span\u003e\u003c\/b\u003e controllers. It offers non-volatile storage for program files and data tables. Engineers use this module to protect critical industrial logic against main battery depletion.\n\u003cp\u003eThis module pairs with the 1747-M15 Series B memory adapter board. It inserts directly onto the processor board inside the controller chassis. Upon power-up, the module automatically reloads the stored user application to ensure immediate system recovery and zero data loss.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eAllen-Bradley\u003c\/span\u003e\u003c\/b\u003e \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eModel Number\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 500\u003c\/span\u003e\u003c\/b\u003e System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eModule Type\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlash Memory Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMemory Capacity\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 Kilobytes (64,000 Words)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMemory Type\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eNon-Volatile Flash PROM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eProgram Scan Time\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.9 milliseconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eI\/O Scan Time\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.225 milliseconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eAdapter Compatibility\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e1747-M15 Series B Adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eCommunication Interfaces\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eEthernet, RS-232 (via Host Processor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMaximum Chassis Support\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 Chassis \/ 30 Slots\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eEnvironmental Endurance\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eIndustrial Grade Operating Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eNoise Immunity\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh Electromagnetic Interference (EMI) Resistance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eCertifications\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eUL, CSA, CE Mark Compliant\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eUNSPSC Code\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e43201402\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eUPC Barcode\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e10662468232910\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eProcessor Compatibility\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 5\/03\u003c\/span\u003e\u003c\/b\u003e Processors: Full execution and program storage support.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 5\/04\u003c\/span\u003e\u003c\/b\u003e Processors: High-speed program recovery for DH+ networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 5\/05\u003c\/span\u003e\u003c\/b\u003e Processors: Seamless memory transfer for Ethernet networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Commissioning Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTurn off system power before seating or removing the module from the processor.\u003c\/li\u003e\n  \u003cli\u003eSet the socket jumper to connect pin A18 to the center pin.\u003c\/li\u003e\n  \u003cli\u003eAlways fit the module into a 1747-M15 Series B memory adapter socket.\u003c\/li\u003e\n  \u003cli\u003eAlign the keyed physical connectors to ensure correct circuit board orientation.\u003c\/li\u003e\n  \u003cli\u003eGround yourself properly to prevent damage from electrostatic discharge (ESD).\u003c\/li\u003e\n  \u003cli\u003eInitiate the burn routine inside RSLogix 500 programming software to store memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe host CPU executes automated checksum tests during every startup cycle.\u003c\/li\u003e\n  \u003cli\u003eProcessor status LEDs signal hardware mismatch or transfer errors instantly.\u003c\/li\u003e\n  \u003cli\u003eRSLogix diagnostic registers log invalid jumper configurations or memory corruption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Experience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eOur automation engineering team frequently sees \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/b\u003e modules deployed in continuous-process environments. In a recent field application at a municipal water facility, power outages coincided with a dead lithium battery on an \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eSLC 5\/04\u003c\/span\u003e\u003c\/b\u003e CPU. Because the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/b\u003e module was correctly flashed, the system restored its program automatically within 3 seconds of power return. This saved the plant hours of costly programming downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eField Tip:\u003c\/b\u003e Never pair the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/b\u003e with older Series A 1747-M15 adapters. Series A adapters supply incorrect pin voltages that permanently damage the flash memory chip.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eSelection \u0026amp; Buyer's Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm your processor program size does not exceed the 64K word limit.\u003c\/li\u003e\n  \u003cli\u003eVerify that your existing adapter is stamped as 1747-M15 Series B.\u003c\/li\u003e\n  \u003cli\u003eChoose standard RAM modules if your application requires constant remote writing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePackaging, Shipping \u0026amp; Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e Includes full 12-Month Quality Warranty coverage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDispatch Time:\u003c\/b\u003e Orders ship within 24 to 48 hours.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eExpress Carriers:\u003c\/b\u003e Expedited global delivery via FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003ePackage List:\u003c\/b\u003e 1 x \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eAllen-Bradley\u003c\/span\u003e\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e1747-M13\u003c\/span\u003e\u003c\/b\u003e Memory Module, Anti-Static Packaging, Insertion Guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eTypical Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote pump stations operating without constant maintenance staff presence.\u003c\/li\u003e\n  \u003cli\u003eAutomated packaging lines requiring high recovery speeds during power losses.\u003c\/li\u003e\n  \u003cli\u003eHigh-vibration manufacturing floors susceptible to battery disconnects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Will the 1747-M13 work without a memory adapter?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, you must install it into a 1747-M15 Series B adapter module first.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What happens if I install the 1747-M13 module while the PLC is powered?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Hot-plugging causes severe hardware damage to both the processor and memory module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How do I load the stored program back into the processor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Configure processor status bit S:1\/15 to reload memory automatically upon power-up.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How do I know if my jumper setting is correct?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify that the physical jumper connects pin A18 directly to the center pin before inserting.\u003c\/p\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013898297526,"sku":"1747-M13","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1747-M13_857584b3-647d-4f64-b8cb-dacf1a3b9a98.jpg?v=1793170688","url":"https:\/\/www.plcsparehub.com\/products\/1747-m13-allen-bradley-slc-500-memory-module-64kb-flash-storage","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}