{"product_id":"1746-ox8-allen-bradley-slc-500-digital-contact-output-module","title":"1746-OX8 Allen-Bradley SLC 500 Digital Contact Output Module","description":"\u003ch3\u003e\u003cstrong\u003e1746-OX8 | Eight-Point Individually Isolated Relay Output\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAllen-Bradley 1746-OX8\u003c\/strong\u003e\u003c\/span\u003e is an eight-point digital contact output module for the \u003cstrong\u003eSLC 500 programmable controller system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike common-group relay modules, this unit provides \u003cstrong\u003eindividual electrical isolation for each output point\u003c\/strong\u003e. This arrangement allows engineers to switch separate AC and DC load circuits through one module.\u003c\/p\u003e\n\u003cp\u003eEach channel uses a normally open (N.O.) relay contact. The module supports operating voltages from \u003cstrong\u003e5 to 265 V AC\u003c\/strong\u003e and \u003cstrong\u003e5 to 125 V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e1746-OX8\u003c\/strong\u003e targets high-current switching applications that require independent output circuits. Typical loads include contactor coils, solenoid valves, motor control interfaces, and industrial alarm devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e1746-OX8\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Contact Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Normally Open Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually Isolated Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible SLC 500 Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen-Type Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e662073896623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Ratings and Contact Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact selection requires more than checking the nominal operating voltage. Engineers must evaluate switching current, continuous current, and load characteristics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eTechnical Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eN.O. Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e5–265 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e5–125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Load Rating\u003c\/td\u003e\n\u003ctd\u003e3 A at 120 V AC; 1.2 A at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e10 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load Delay\u003c\/td\u003e\n\u003ctd\u003e10 ms ON \/ 10 ms OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 5 V DC\u003c\/td\u003e\n\u003ctd\u003e85 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 24 V DC\u003c\/td\u003e\n\u003ctd\u003e90 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O to Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Contact Ratings by Load Voltage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following ratings distinguish contact switching capacity from continuous operating current.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eContact Voltage\u003c\/th\u003e\n\u003cth\u003eMaximum Make Current\u003c\/th\u003e\n\u003cth\u003eMaximum Break Current\u003c\/th\u003e\n\u003cth\u003eContinuous Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 V AC\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 V DC\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Load Limitation:\u003c\/strong\u003e The total continuous module load must remain within 1440 VA. Individual contact ratings also apply. Never use the make-current rating as a continuous load rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical and Environmental Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration, 5–57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015-inch peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration, 57–2000 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 g acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.825 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Heat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.590 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Heat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel Isolation and Load Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1746-OX8\u003c\/strong\u003e uses individually isolated relay contacts. Each output can switch a separate external circuit within its rated electrical limits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent Circuits:\u003c\/strong\u003e Separate output points support different load voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Switching:\u003c\/strong\u003e Relay contacts support specified AC and DC applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e The module provides 1500 V isolation between I\/O terminals and control logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Off-State Leakage:\u003c\/strong\u003e The specified maximum off-state leakage is 0 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Protection:\u003c\/strong\u003e External surge suppression helps protect relay contacts from inductive switching transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Engineering Note:\u003c\/strong\u003e Relay contacts experience electrical arcing when switching inductive loads. Install suitable suppression across external coils. This helps reduce contact erosion and extends relay service life.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Field Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Remove power from the chassis before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Chassis:\u003c\/strong\u003e Confirm compatibility with the SLC 500 rack configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Terminals:\u003c\/strong\u003e Check the removable terminal block and contact condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentify Load Circuits:\u003c\/strong\u003e Confirm the voltage and current requirements for every output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Individual Channels:\u003c\/strong\u003e Maintain separate circuit identification for each isolated relay point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Suppression:\u003c\/strong\u003e Add suitable protection for inductive loads where required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Wiring:\u003c\/strong\u003e Verify terminal tightness, polarity where applicable, and circuit isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestore Power:\u003c\/strong\u003e Apply power after completing installation checks.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Warning:\u003c\/strong\u003e Never insert or remove the module while chassis power is applied. Follow the official installation instructions and site electrical safety procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance Strategy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRelay output diagnostics require both PLC-side checks and field-side electrical measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Command:\u003c\/strong\u003e Confirm that the PLC program issues the expected output command.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Status:\u003c\/strong\u003e Check the corresponding module status indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Continuity:\u003c\/strong\u003e Test relay contact operation with the circuit safely isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Current:\u003c\/strong\u003e Measure actual current under operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Wear:\u003c\/strong\u003e Inspect for signs of overheating, pitting, or abnormal switching behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuppression Components:\u003c\/strong\u003e Check external surge suppressors and coil protection devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Conditions:\u003c\/strong\u003e Confirm that cabinet ventilation supports the module's heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Recommendation:\u003c\/strong\u003e If the PLC command changes but the field load does not respond, check the external supply and relay contact path. Do not immediately assume a CPU or program fault.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility and Application Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e1746-OX8\u003c\/strong\u003e\u003c\/span\u003e belongs to the \u003cstrong\u003eAllen-Bradley SLC 500\u003c\/strong\u003e digital output family.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Platform:\u003c\/strong\u003e Designed for compatible SLC 500 chassis configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Interface:\u003c\/strong\u003e Eight individually isolated N.O. relay contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Compatibility:\u003c\/strong\u003e Supports specified AC and DC load circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Applications:\u003c\/strong\u003e Suitable for switching contactors, solenoids, alarms, and auxiliary equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Checks:\u003c\/strong\u003e Verify chassis compatibility, terminal arrangement, load ratings, and wiring before substitution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis module is particularly useful when output circuits require different voltage levels. Its isolated contacts also help separate external control circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe manufacturer provides product-specific regulatory and certification information.\u003c\/li\u003e\n\u003cli\u003eHistorical installation documentation identifies CSA Class I, Division 2 certification for applicable configurations.\u003c\/li\u003e\n\u003cli\u003eVerify the module label and applicable certification documents before hazardous-area installation.\u003c\/li\u003e\n\u003cli\u003eFollow local electrical codes and enclosure requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Allen-Bradley 1746-OX8 Digital Contact Output Module.\u003c\/li\u003e\n\u003cli\u003eTerminal block or additional accessories: Confirm according to the specific order configuration.\u003c\/li\u003e\n\u003cli\u003eTechnical documentation: Available upon request, subject to availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ – Relay Output Engineering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why can an output indicator change state while the connected contactor remains inactive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe indicator reflects the module's control status, not necessarily successful load energization. Check the external AC\/DC supply, terminal wiring, fuse protection, and relay contact continuity. A worn contact or an open field circuit can prevent the contactor from operating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens when a relay output switches a contactor coil without surge suppression?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInductive energy can generate voltage transients when the relay opens. These transients increase electrical arcing across the contacts. Repeated switching can accelerate contact wear. Select an appropriate suppression device for the coil voltage and circuit type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can all eight channels switch their maximum rated current simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. Each contact has its own switching limits. The complete module must also remain within the 1440 VA continuous power limitation. Calculate the combined load before commissioning. Consider the load duty cycle and switching frequency during the assessment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why might a small electronic load fail to operate reliably through a mechanical relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMechanical contacts require a suitable minimum load for reliable contact performance. The specified minimum load is 10 mA at 5 V DC. Very low-current electronic inputs may require an interposing relay or another suitable interface. Check the actual load characteristics before connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should engineers evaluate relay output suitability for frequent switching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the load's inrush current, operating voltage, switching frequency, and inductive characteristics. Compare these values with the contact make, break, and continuous ratings. Also consider relay mechanical and electrical life. For high-frequency switching, evaluate a solid-state output alternative when the application permits.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013898133686,"sku":"1746-OX8","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1746-OX8_75bc7e97-3730-4eaf-bf1e-9096b41cca01.jpg?v=1795414512","url":"https:\/\/www.plcsparehub.com\/products\/1746-ox8-allen-bradley-slc-500-digital-contact-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}