{"product_id":"16925-99-bently-nevada-3-conductor-shielded-interconnect-cable","title":"16925-99 Bently Nevada 3-Conductor Shielded Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e16925-99\u003c\/span\u003e interconnect cable from \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003eBently Nevada\u003c\/span\u003e provides dependable signal transmission between monitoring systems and field hardware. This 3-conductor shielded assembly ensures noise-free signal delivery across extended equipment runs in industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration Breakdown \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\" border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003cth style=\"padding: 10px; text-align: left;\"\u003eCable Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; text-align: left;\"\u003eEngineering Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eBrand \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eBently Nevada | \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e16925-99\u003c\/span\u003e (\u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003eInterconnect Cable Series\u003c\/span\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eLength Option (-99 Suffix)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e99 feet (30 meters) total custom-cut length (Range: 2.0 ft to 99 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eConductor Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e3-conductor shielded 22 AWG (0.5 mm2) stranded copper wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eTermination Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e3-socket plug at one end, bare terminal lugs at the opposite end\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eShielding \u0026amp; Noise Immunity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eContinuous overall electrostatic shield to suppress electromagnetic interference\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e16925-99\u003c\/span\u003e wire harness integrates seamlessly with standard \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003eBently Nevada rack monitors\u003c\/span\u003e and signal conditioning units. It links remote terminal blocks to front-panel inputs without signal attenuation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMeasure the exact routing distance between your monitor rack and terminal box prior to cutting.\u003c\/li\u003e\n  \u003cli\u003eConnect the 3-socket plug securely into the designated module receptacle.\u003c\/li\u003e\n  \u003cli\u003eAttach the terminal lugs firmly to screw-type barrier strips in the junction box.\u003c\/li\u003e\n  \u003cli\u003eEnsure the cable shield is grounded correctly at a single end to eliminate ground loops.\u003c\/li\u003e\n  \u003cli\u003eSecure the cable along cable trays using nylon ties while respecting minimum bend thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommissioning and Maintenance Convenience\u003c\/h3\u003e\n\u003cp\u003ePre-terminated ends save instrument technicians considerable time during plant startup phases. The flexible 22 AWG stranded construction permits smooth pulling through congested conduit pipes. Clear terminal lug identification minimizes wiring errors during multi-channel loop checks.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Scenarios and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Interfacing:\u003c\/strong\u003e Links control room monitoring racks to field termination panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Acquisition:\u003c\/strong\u003e Transmits raw vibration and position signals to external diagnostic computers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Mitigation:\u003c\/strong\u003e Prevents industrial plant electrical noise from corrupting low-voltage dynamic signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCertification, Packing List, and Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Manufactured to standard industrial instrumentation specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePacking List:\u003c\/strong\u003e One \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e16925-99\u003c\/span\u003e cable assembly in original protective packaging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Covered by a comprehensive 12-month manufacturer warranty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLogistics:\u003c\/strong\u003e Fast dispatch within 24-48 hours via premium carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eOur engineering team at Global PLC Spare HUB frequently encounters intermittent signal noise caused by improper shield grounding. When installing the \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e16925-99\u003c\/span\u003e, always verify that the drain wire connects strictly to the designated instrument ground terminal and remains isolated from structural earth.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Guide\u003c\/h3\u003e\n\u003cp\u003eSelect your total cable length suffix based on actual physical routing paths plus a 10 percent slack allowance. Ensure 3-conductor configurations match your specific monitor input requirements before ordering custom-tailored lengths.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e16925-99\u003c\/span\u003e cable length be shortened on-site during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, technicians can cut the terminal lug end to fit shorter runs, but the 3-socket molded plug end cannot be modified in the field.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Why is a 3-conductor shielded design necessary for vibration monitor interconnects?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The three conductors handle power supply, common return, and signal transmission, while the shield blocks external electromagnetic interference.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum allowable distance when utilizing this interconnect cable type?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The maximum factory-supported length option for this series is 99 feet (30 meters) to prevent excessive capacitive signal loading.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does stranded 22 AWG wire perform under continuous mechanical vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Stranded copper conductors offer superior flexibility and fatigue resistance compared to solid core wire in vibrating industrial settings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Are replacement terminal lugs required if the wire is pulled through narrow conduits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is recommended to protect the terminal lug end with pulling socks during tight conduit pulls to prevent lug deformation or detachment.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013805236406,"sku":"16925-99","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/16925-99_2_f254a27f-d2ea-48ff-9b71-67aa551dc5e2.jpg?v=1789454801","url":"https:\/\/www.plcsparehub.com\/products\/16925-99-bently-nevada-3-conductor-shielded-interconnect-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}