{"product_id":"16925-20-bently-nevada-interconnect-cable-3-conductor-shielded-20ft","title":"16925-20 Bently Nevada Interconnect Cable 3-Conductor Shielded 20ft","description":"\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e16925-20 Bently Nevada Interconnect Cable Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d9534f;\"\u003e16925-20\u003c\/span\u003e\u003c\/strong\u003e provides high-integrity signal transmission between dynamic vibration transmitters, Proximitor sensors, and monitoring system terminal blocks.\u003c\/p\u003e\n\n\u003cp\u003eManufactured by \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e, this heavy-duty \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eInterconnect Cable\u003c\/span\u003e\u003c\/strong\u003e features a 3-conductor 22 AWG shielded design engineered to isolate critical transducer signals from industrial electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003cp\u003eEquipped with a factory-molded 3-socket plug on one end and precision terminal lugs on the opposite end, it delivers reliable, low-attenuation point-to-point wiring for machinery protection systems.\u003c\/p\u003e\n\n\u003cp\u003eThe 20-foot (6.1 m) length ensures low signal loss across standard cabinet-to-junction-box distances in power generation, petrochemical, and industrial manufacturing plants.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eConfiguration Breakdown \u0026amp; Suffix Tree Structure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eBase Part Number:\u003c\/strong\u003e 16925 - 3-Conductor Shielded Transducer Interconnect Cable\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTermination Profile:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eEnd A: Integrated 3-socket female connector plug\u003c\/li\u003e\n      \u003cli\u003eEnd B: Pre-crimped spade\/ring terminal lugs\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Gauge:\u003c\/strong\u003e 22 AWG (0.5 mm²) stranded copper conductors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding Architecture:\u003c\/strong\u003e 100% coverage braid\/foil shield with drain wire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length Suffix (-20):\u003c\/strong\u003e 20 Feet (6.1 meters) total length\n    \u003cul\u003e\n      \u003cli\u003eMinimum Available Range: -02 (2.0 ft \/ 0.6 m)\u003c\/li\u003e\n      \u003cli\u003eMaximum Available Range: -99 (99 ft \/ 30 m)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTechnical \u0026amp; Physical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #d9534f;\"\u003e16925-20\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eConductor Specification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e3-conductor, 22 AWG (0.5 mm²) stranded wire\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eOverall shield with continuous drain wire grounding\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eConnector A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e3-socket molded female plug\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eConnector B\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eInsulated terminal lugs (fork\/ring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e20 Feet (6.1 meters)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eOil-resistant, flame-retardant industrial elastomer\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Application Environments\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003eInterfacing Bently Nevada 3300\/3500 monitoring racks with field-mounted Proximitor sensor units.\u003c\/p\u003e\n\n\u003cp\u003eConnecting thrust and radial vibration transducers on boiler feed pumps and steam turbines.\u003c\/p\u003e\n\n\u003cp\u003eRelaying dynamic signals from seismic velocity pickup sensors inside hazardous plant areas.\u003c\/p\u003e\n\n\u003cp\u003eWiring centrifugal compressor monitoring channels to intermediate terminal junction boxes.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eInstallation Best Practices \u0026amp; Signal Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003eRoute cable through dedicated grounded metallic conduit away from high-voltage VFD motor drives.\u003c\/p\u003e\n\n\u003cp\u003eEnsure terminal lug screws are torqued properly to avoid high-resistance point connections.\u003c\/p\u003e\n\n\u003cp\u003eConnect cable drain wire strictly at one grounding point to eliminate ground loop voltage spikes.\u003c\/p\u003e\n\n\u003cp\u003eVerify raw AC\/DC signal voltage at terminal lugs using an oscilloscope during commissioning.\u003c\/p\u003e\n\n\u003cp\u003eHigh high-frequency noise floor readings indicate ungrounded shielding or crushed outer cable jacketing.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eCommercial Terms, Shipping, \u0026amp; Warranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eProduct Condition\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e100% Brand New \u0026amp; Original Factory Sealed\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eFactory Warranty\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e12-Month Replacement Warranty\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eDispatch Standard\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eExpress processing within 24–48 hours\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eGlobal Carrier Options\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eFedEx Express, UPS Worldwide, DHL Express\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003eSpurious vibration trips in rotating machinery are frequently traced to faulty interconnect cabling.\u003c\/p\u003e\n\n\u003cp\u003eOur instrumentation engineers often discover signal degradation caused by field technicians pulling cables past tight bend radiuses.\u003c\/p\u003e\n\n\u003cp\u003eExcessive physical stress on the 22 AWG wire breaks internal drain connections, exposing the 3300 system to ground loops.\u003c\/p\u003e\n\n\u003cp\u003eUsing factory-terminated assemblies like the \u003cstrong\u003e\u003cspan style=\"color: #d9534f;\"\u003e16925-20\u003c\/span\u003e\u003c\/strong\u003e ensures low contact resistance at the 3-socket interface.\u003c\/p\u003e\n\n\u003cp\u003eAlways inspect the 3-socket connector pins for oxidation or bent pins prior to securing coupling rings in humid environments.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSelection \u0026amp; Buyer Guidance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003eMeasure physical cable tray distance before ordering; avoid tight cable tension by allowing 10% slack length.\u003c\/p\u003e\n\n\u003cp\u003eConfirm whether your receiver module requires spade terminal lugs or raw stripped ends before final mounting.\u003c\/p\u003e\n\n\u003cp\u003eVerify that 20 feet (6.1 m) does not exceed maximum allowable loop resistance for your specific sensor model.\u003c\/p\u003e\n\n\u003cp\u003eCheck if outer armoring is needed; standard elastomer jacketing requires conduit protection in heavy foot-traffic areas.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion: What does the -20 suffix indicate for this cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The -20 suffix specifies a total physical length of 20 feet (6.1 meters) from plug tip to terminal lugs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion: What conductor wire gauge is utilized inside this assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: It utilizes 3-conductor 22 AWG (0.5 mm²) stranded copper wire with full shield coverage and a drain wire.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion: How are the conductor ends terminated opposite the 3-socket plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The opposite end is terminated with factory-crimped terminal lugs designed for screw terminal barrier blocks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion: Practical Engineering: How do I test if an installed cable assembly has an internal short or open line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Disconnect both ends. Use a digital multimeter to measure resistance pin-to-pin (should read open circuit) and pin-to-lug (should read near 0 ohms). Resistance above 2 ohms indicates conductor fatigue or bad crimps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion: Procurement Advice: Can I splice two shorter cables together if 20 feet is insufficient for field routing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Field splicing transducer cables is strongly discouraged. In-line terminal blocks break shield continuity, introducing EMI noise into your vibration monitor. Order a longer factory assembly (up to -99 feet) instead.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013973205174,"sku":"16925-20","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/16925-99_2_f670c510-1562-413e-9c11-7897e396d95f.jpg?v=1788859431","url":"https:\/\/www.plcsparehub.com\/products\/16925-20-bently-nevada-interconnect-cable-3-conductor-shielded-20ft","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}