{"product_id":"164818-08-60-022-02-01-03-05-bently-nevada-proximity-probe-housing","title":"164818-08-60-022-02-01-03-05 Bently Nevada Proximity Probe Housing","description":"\n\u003ch2\u003e164818-08-60-022-02-01-03-05 | Bently Nevada Compact Proximity Probe Housing\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 164818-08-60-022-02-01-03-05\u003c\/strong\u003e is a compact proximity probe housing assembly designed to support probe installation where machinery layout or access space limits conventional mounting arrangements. The assembly incorporates a housing body, screw-on dome cover, threaded conduit ports, probe sleeve, O-rings, a reverse-mount proximity probe, and a thread seal. Optional conduit fittings and a standoff adapter may be available depending on the selected configuration.\u003c\/p\u003e\n\n\u003cp\u003eThis model code specifies a 3300 8 mm ceramic-capped probe, a 6.0-inch cap height, a 2.2-inch sleeve, a G 3\/4 mounting thread, Viton O-rings, an ethylene-propylene rear-thread option, and a 0.5-meter probe cable. Confirm the mounting interface, probe clearances, sealing materials, and cable routing before installation.\u003c\/p\u003e\n\n\u003ch3\u003e01 | Assembly Architecture\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eAssembly Element\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eInstallation Consideration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDome cover\u003c\/td\u003e\n      \u003ctd\u003eScrews into the housing body to enclose the assembly\u003c\/td\u003e\n      \u003ctd\u003eCheck thread condition and ensure the cover is properly seated.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThreaded conduit ports\u003c\/td\u003e\n      \u003ctd\u003eProvide interfaces for conduit connections\u003c\/td\u003e\n      \u003ctd\u003eVerify fitting thread compatibility, cable protection, and routing clearance.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe sleeve\u003c\/td\u003e\n      \u003ctd\u003ePositions and supports the probe assembly\u003c\/td\u003e\n      \u003ctd\u003eConfirm the specified 2.2-inch sleeve length suits the machine geometry.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eO-rings\u003c\/td\u003e\n      \u003ctd\u003eProvide sealing at designated interfaces\u003c\/td\u003e\n      \u003ctd\u003eCheck material compatibility, surface condition, and correct installation.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eReverse-mount proximity probe\u003c\/td\u003e\n      \u003ctd\u003eProvides the probe element for the intended proximity measurement system\u003c\/td\u003e\n      \u003ctd\u003eVerify probe type, connector arrangement, system compatibility, and mounting orientation.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread seal\u003c\/td\u003e\n      \u003ctd\u003eSupports sealing at the specified threaded interface\u003c\/td\u003e\n      \u003ctd\u003eInspect for damage and follow the applicable installation procedure.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptional conduit fittings\u003c\/td\u003e\n      \u003ctd\u003eAdapt the conduit connection to the installation arrangement\u003c\/td\u003e\n      \u003ctd\u003eConfirm whether the required fittings are included in the supplied assembly.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptional standoff adapter\u003c\/td\u003e\n      \u003ctd\u003eProvides an alternative mounting arrangement where required\u003c\/td\u003e\n      \u003ctd\u003eVerify the adapter requirement against available clearance and mounting drawings.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e02 | Configuration Breakdown — Decode the Full Part Number\u003c\/h3\u003e\n\u003cp\u003eUse the following code tree to identify the specified assembly configuration. The interpretation follows the supplied model-code information.\u003c\/p\u003e\n\n\u003cpre\u003e\n164818-08-60-022-02-01-03-05\n|\n+-- 164818  Compact proximity probe housing assembly\n|\n+-- 08      Probe configuration\n|           3300 8 mm ceramic-capped probe\n|           with multiple approvals, as specified\n|\n+-- 60      Cap height\n|           6.0 inches\n|\n+-- 022     Probe sleeve length\n|           2.2 inches\n|\n+-- 02      Mounting thread\n|           G 3\/4 (3\/4-14 BSPP)\n|\n+-- 01      O-ring option\n|           Viton\n|\n+-- 03      Rear-thread option\n|           Ethylene propylene, as specified\n|\n+-- 05      Probe cable length\n            0.5 meter (20 inches)\n\u003c\/pre\u003e\n\n\u003ch3\u003e03 | Configuration Reference Table\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCode Segment\u003c\/th\u003e\n      \u003cth\u003eSpecified Option\u003c\/th\u003e\n      \u003cth\u003eSelection and Verification Notes\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e164818\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCompact proximity probe housing\u003c\/td\u003e\n      \u003ctd\u003eCheck the overall assembly dimensions and installation drawing.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 8 mm ceramic-capped probe with multiple approvals\u003c\/td\u003e\n      \u003ctd\u003eConfirm that the probe configuration and required approvals match the installation requirements.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e60\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0-inch cap height\u003c\/td\u003e\n      \u003ctd\u003eVerify the reference point used for this dimension in the manufacturer's drawing.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e022\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.2-inch probe sleeve\u003c\/td\u003e\n      \u003ctd\u003eCheck available mounting depth and probe positioning requirements.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eG 3\/4 mounting thread, 3\/4-14 BSPP\u003c\/td\u003e\n      \u003ctd\u003eVerify the mating thread standard. Do not substitute NPT or another thread form based on nominal size alone.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring option\u003c\/td\u003e\n      \u003ctd\u003eConfirm chemical, temperature, and media compatibility for the actual installation.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEthylene-propylene rear-thread option\u003c\/td\u003e\n      \u003ctd\u003eVerify the exact seal or material designation in the applicable manufacturer documentation.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5-meter (20-inch) probe cable\u003c\/td\u003e\n      \u003ctd\u003eConfirm that the cable reaches the connection point without tension or an unsuitable bend radius.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration caution:\u003c\/strong\u003e The supplied description uses “ethylene propylene” for code 03 without fully defining its precise component or material designation. Verify this suffix against the manufacturer's code table before making a material-compatibility decision.\u003c\/p\u003e\n\n\u003ch3\u003e04 | Suitable Machinery and Application Scenarios\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eEquipment or Area\u003c\/th\u003e\n      \u003cth\u003ePotential Use\u003c\/th\u003e\n      \u003cth\u003eEngineering Checks\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSteam and gas turbines\u003c\/td\u003e\n      \u003ctd\u003eHousing a compatible proximity probe in a machinery-monitoring installation\u003c\/td\u003e\n      \u003ctd\u003eCheck mounting geometry, probe target clearance, and the approved monitoring-system configuration.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCentrifugal compressors\u003c\/td\u003e\n      \u003ctd\u003eProbe installation where access or surrounding structure restricts available space\u003c\/td\u003e\n      \u003ctd\u003eVerify sleeve length, conduit routing, and the required probe orientation.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIndustrial pumps\u003c\/td\u003e\n      \u003ctd\u003eSupporting a suitable proximity probe arrangement for rotating machinery monitoring\u003c\/td\u003e\n      \u003ctd\u003eCheck target material, probe-system compatibility, and environmental sealing requirements.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGearboxes and rotating equipment\u003c\/td\u003e\n      \u003ctd\u003eProviding a compact mounting assembly at a suitable measurement location\u003c\/td\u003e\n      \u003ctd\u003eConfirm shaft clearance, vibration exposure, and mounting rigidity.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpace-restricted machinery skids\u003c\/td\u003e\n      \u003ctd\u003eInstalling a probe where a conventional housing may not fit\u003c\/td\u003e\n      \u003ctd\u003eReview the full assembly envelope, cap clearance, cable exit, and maintenance access.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePlant machinery protection systems\u003c\/td\u003e\n      \u003ctd\u003eSupporting a compatible probe installation within an engineered monitoring arrangement\u003c\/td\u003e\n      \u003ctd\u003eVerify the complete probe, extension cable, monitor input, and applicable system requirements.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThese are potential application categories for a compatible proximity-probe installation. The housing itself does not establish a complete machinery protection function; measurement performance depends on the probe system, target, wiring, monitor configuration, and installation quality.\u003c\/p\u003e\n\n\u003ch3\u003e05 | Installation Practices for Field Engineers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCheck the mounting thread:\u003c\/strong\u003e Confirm the specified G 3\/4 (3\/4-14 BSPP) interface and the mating component's thread form before assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify dimensional clearance:\u003c\/strong\u003e Check the 6.0-inch cap-height specification and 2.2-inch sleeve length against the equipment drawing and available maintenance space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInspect sealing components:\u003c\/strong\u003e Check the O-rings and thread seal for damage, contamination, or incorrect installation. Confirm material suitability for the operating environment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtect the cable:\u003c\/strong\u003e Route the 0.5-meter cable without pulling on the probe connector. Maintain the manufacturer's specified bend radius and separation from noise-producing power wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCheck the probe target:\u003c\/strong\u003e Verify the target material, probe orientation, required gap, and probe-system calibration procedure using the applicable 3300 system documentation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfirm electrical compatibility:\u003c\/strong\u003e Check the probe, extension cable, and monitoring input as a complete system. Do not assume that an 8 mm probe is interchangeable with every other proximity-probe system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDocument the final setup:\u003c\/strong\u003e Record the part number, mounting dimensions, cable route, probe gap, and any measured baseline values for future maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e06 | Field Diagnostics: Symptoms, Causes, and Checks\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eObserved Symptom\u003c\/th\u003e\n      \u003cth\u003ePotential Cause\u003c\/th\u003e\n      \u003cth\u003eRecommended Checks\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnstable proximity readings after installation\u003c\/td\u003e\n      \u003ctd\u003eLoose mounting, poor cable routing, incorrect probe gap, or an electrical connection issue\u003c\/td\u003e\n      \u003ctd\u003eInspect mechanical rigidity and connections. Verify the probe gap and signal using the approved system procedure.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMoisture or contamination inside the housing\u003c\/td\u003e\n      \u003ctd\u003eDamaged O-rings, an improperly seated cover, or a poorly sealed conduit interface\u003c\/td\u003e\n      \u003ctd\u003eInspect the cover, seals, and conduit fittings. Replace damaged sealing components using approved parts and procedures.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing cannot be installed on the mating port\u003c\/td\u003e\n      \u003ctd\u003eIncorrect thread standard, damaged threads, or a mismatch in mounting dimensions\u003c\/td\u003e\n      \u003ctd\u003eConfirm G 3\/4 BSPP compatibility and inspect both mating threads. Do not force incompatible threads together.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe cable does not reach the termination point\u003c\/td\u003e\n      \u003ctd\u003eIncorrect cable-length selection or a changed routing path\u003c\/td\u003e\n      \u003ctd\u003eMeasure the actual routing distance and verify the specified 0.5-meter cable. Check the approved configuration before selecting another length.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe signal is consistently outside the expected range\u003c\/td\u003e\n      \u003ctd\u003eIncorrect gap, incompatible probe-system components, target issues, or a probe or cable fault\u003c\/td\u003e\n      \u003ctd\u003eCheck the complete probe system and target condition. Follow the monitoring system's troubleshooting procedure before replacing the housing.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation requires more space than expected\u003c\/td\u003e\n      \u003ctd\u003eCap height, sleeve projection, conduit fittings, or optional adapter clearance was not included in the layout review\u003c\/td\u003e\n      \u003ctd\u003eCompare the complete assembly with the manufacturer's dimensional drawing, including cable exit and maintenance access.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eDiagnostic distinction:\u003c\/strong\u003e A housing-related problem often involves mounting, sealing, clearance, or cable protection. An abnormal proximity signal may instead originate in the probe, extension cable, target, or monitor channel. Check the entire measurement chain before concluding that the housing is defective.\u003c\/p\u003e\n\n\u003ch3\u003e07 | Global PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eFor a compact proximity-probe installation, the most important selection details are the mounting thread, sleeve length, cap clearance, sealing materials, and cable reach. A housing that fits the nominal thread may still be unsuitable if the probe position or surrounding structure differs from the original installation.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor replacement planning:\u003c\/strong\u003e Match the full suffix string rather than ordering by the base number alone. The suffixes define important mechanical and probe-configuration details.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor reliability work:\u003c\/strong\u003e Inspect the sealing interfaces and conduit connections during scheduled maintenance, especially when moisture or contamination has been observed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor vibration-monitoring engineers:\u003c\/strong\u003e Validate probe gap and signal behavior against the applicable monitoring-system procedure. Do not use housing dimensions as a substitute for electrical calibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor restricted installations:\u003c\/strong\u003e Check the entire assembly envelope, including the dome cover, conduit fittings, cable bend radius, and removal space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThis review focuses on mechanical fit and measurement-system integration. Confirm the final configuration against the official Bently Nevada documentation and the installed machinery drawings before ordering or commissioning.\u003c\/p\u003e\n\n\u003ch3\u003e08 | Global PLC Spare HUB Review\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 164818-08-60-022-02-01-03-05\u003c\/strong\u003e is a defined compact housing assembly for a specified 3300 8 mm ceramic-capped proximity probe configuration. Its listed sleeve length, mounting thread, O-ring option, rear-thread designation, and cable length provide a practical basis for replacement screening.\u003c\/p\u003e\n\n\u003cp\u003eBefore purchase, verify the mounting interface, sealing-material compatibility, overall clearance, and the required probe-system configuration. For an existing installation, comparing the complete part number and mechanical dimensions is more reliable than selecting a housing from its family number alone.\u003c\/p\u003e\n\n\u003ch3\u003e09 | Warranty and Shipping\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the applicable seller warranty terms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Provide the full part number and, if possible, the installed probe or machinery details to support a configuration review.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuotation support:\u003c\/strong\u003e Contact Global PLC Spare HUB for current pricing, availability, and order information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e10 | Frequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Why should I match every suffix instead of ordering another 164818 housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The suffixes identify configuration details such as probe type, cap height, sleeve length, mounting thread, sealing options, and cable length. A housing from the same family may have a different installation interface or probe arrangement. Compare the complete part number and dimensional drawing before approving a replacement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can the G 3\/4 mounting thread be replaced with a similarly sized NPT fitting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Do not assume these threads are interchangeable. G 3\/4 BSPP and NPT use different thread forms and sealing approaches. Confirm the mating port specification and use an approved interface rather than forcing or adapting the connection without engineering review.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What should I investigate if the housing is dry but the proximity signal remains unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Expand the investigation beyond the housing. Check probe gap, mounting rigidity, cable and connector condition, target surface, and compatibility between the probe, extension cable, and monitor input. Compare readings with the system's approved commissioning procedure to isolate the source of the fault.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: How can I determine whether the 0.5-meter cable is long enough?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Measure the actual cable route from the probe connection to the intended termination point, including bends, strain relief, and service access. Avoid a taut cable or bends tighter than the manufacturer's limit. If the length is insufficient, verify an approved alternative configuration rather than adding an unverified extension.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Which details should I send when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Provide the full part number, required quantity, photographs of the nameplate or installed assembly, mounting-thread details, and available dimensional information. If the request follows a fault, describe the symptom and whether it involves leakage, physical interference, or unstable probe readings. This helps distinguish a housing replacement from a wider probe-system issue.\u003c\/p\u003e\n\n\u003ch3\u003eRequest Pricing and Configuration Review\u003c\/h3\u003e\n\u003cp\u003eNeed the \u003cstrong\u003eBently Nevada 164818-08-60-022-02-01-03-05 Compact Proximity Probe Housing\u003c\/strong\u003e? Contact Global PLC Spare HUB with your complete part number and installation requirements to request pricing, availability, and configuration support.\u003c\/p\u003e\n","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67716339138742,"sku":"164818-08-60-022-02-01-03-05","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/164818.jpg?v=1792641418","url":"https:\/\/www.plcsparehub.com\/products\/164818-08-60-022-02-01-03-05-bently-nevada-proximity-probe-housing","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}