{"product_id":"164818-00-20-020-01-01-01-00-bently-nevada-proximity-probe-housing","title":"164818-00-20-020-01-01-01-00 Bently Nevada Proximity Probe Housing","description":"\n\u003ch3\u003e\u003cb\u003eBently Nevada 164818-00-20-020-01-01-01-00 — Compact Proximity Probe Housing\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #1673B1;\"\u003e164818-00-20-020-01-01-01-00\u003c\/span\u003e\u003c\/b\u003e is a Bently Nevada compact proximity probe housing assembly intended to provide a protected mounting arrangement for a reverse-mount proximity probe. Its compact format is useful where machinery layout limits the space available for probe installation.\u003c\/p\u003e\n\n\u003cp\u003eThe assembly design can include a dome cover, conduit connection ports, a probe sleeve, O-rings, a reverse-mount probe, thread sealing components and optional fittings or a standoff adapter. The supplied configuration code indicates a 2.0-inch cap height, 2.0-inch sleeve, 3\/4-14 NPT mounting thread, Viton O-ring option and 1\/2-14 NPT rear thread. It specifies no probe and no probe cable, so verify the complete delivered bill of materials before installation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eConfiguration Decode — From Order Code to Hardware\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: #1673B1;\"\u003e164818-AA-BB-CCC-DD-EE-FF-GG\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCode field\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eSelected value\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eConfiguration meaning\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAA — Probe option\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e00\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNo probe specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBB — Cap height\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 inches.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC — Sleeve length\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e020\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 inches.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDD — Mounting thread\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e01\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEE — O-ring option\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e01\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eViton.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFF — Rear thread\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e01\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2-14 NPT.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGG — Probe cable length\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e00\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNo probe cable specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cb\u003eConfiguration caution:\u003c\/b\u003e The source code legend contains a wording inconsistency (“Probe with Connector” and “00: No probe”) and a typo in the cable description. This page interprets the selected “00” values as “no probe” and “no probe cable,” consistent with the supplied option descriptions. Confirm the manufacturer’s exact ordering documentation and the delivered assembly contents before purchase.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eAssembly Elements and Interface Details\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDome cover:\u003c\/b\u003e Screws into the housing body to enclose the probe installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProbe sleeve:\u003c\/b\u003e Selected length establishes the probe’s mounting arrangement; this code specifies 2.0 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConduit ports and rear thread:\u003c\/b\u003e Provide connection points for compatible conduit or cable-routing hardware. Confirm fittings and thread engagement requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting interface:\u003c\/b\u003e 3\/4-14 NPT for the selected configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSealing:\u003c\/b\u003e Viton O-ring option and a thread seal are described in the assembly information. Verify chemical compatibility, temperature limits and the correct sealing procedure for the actual installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProbe and cable:\u003c\/b\u003e The selected code specifies neither. A compatible reverse-mount probe and its cable must be separately confirmed if required for the monitoring installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOptional hardware:\u003c\/b\u003e Conduit fittings and a standoff adapter may be options; their inclusion is not established by the supplied code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eApplication Fit — Machinery and Installation Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSpace-constrained machinery:\u003c\/b\u003e Compact probe mounting locations where a larger housing would interfere with nearby components or access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRotating equipment monitoring:\u003c\/b\u003e Installation points for compatible proximity probes used to measure shaft-relative vibration or displacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial machinery protection systems:\u003c\/b\u003e Probe mounting arrangements associated with compatible Bently Nevada monitoring channels, subject to the probe, extension cable and monitor requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaintenance or retrofit work:\u003c\/b\u003e Replacement of a matching housing assembly where existing mounting threads, sleeve geometry and probe orientation are verified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCeramic-capped probe installations:\u003c\/b\u003e The product information states that ceramic-capped probes are available with this housing; confirm the exact probe model and assembly configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe housing is a mechanical installation component, not a standalone measurement or monitoring device. Its suitability depends on the probe model, target geometry, mounting clearance, thread interfaces, cable routing and the machinery protection system’s electrical requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation Checks for Reliability\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eConfirm probe selection:\u003c\/b\u003e Identify the exact reverse-mount proximity probe required by the monitoring channel. Do not assume a probe is included in this “00” configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVerify geometry:\u003c\/b\u003e Check sleeve length, cap height, mounting depth, probe orientation and clearance to the shaft or target. Confirm the required probe gap and target material using the probe documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCheck thread interfaces:\u003c\/b\u003e Confirm the 3\/4-14 NPT mounting thread and 1\/2-14 NPT rear thread against the machine and conduit arrangement. Avoid forcing mismatched threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInspect seals:\u003c\/b\u003e Verify O-ring condition and compatibility with the installation environment. Follow the manufacturer’s recommended assembly and sealing procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePlan cable routing:\u003c\/b\u003e Since no cable is specified, select the correct cable and routing hardware for the chosen probe and monitor. Maintain required bend radius and protect the cable from abrasion and electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eValidate the measurement chain:\u003c\/b\u003e After installation, check probe gap, signal polarity, monitor channel configuration and the resulting measurement against the system documentation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cb\u003eDiagnostics — What to Check When a Probe Channel Misbehaves\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe housing does not itself provide electronic diagnostics. Troubleshooting should distinguish mechanical mounting issues from probe, cable or monitoring-channel faults.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eUnstable or noisy readings:\u003c\/b\u003e Inspect housing rigidity, probe clearance, cable routing, connector condition and nearby electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUnexpected gap or measurement offset:\u003c\/b\u003e Verify probe position, sleeve and standoff geometry, target surface and the monitor’s configured calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNo signal or channel fault:\u003c\/b\u003e Confirm that a probe and compatible cable are actually installed, then check connections, probe compatibility and monitor input configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePossible sealing or contamination issue:\u003c\/b\u003e Inspect O-rings, thread seals and conduit entries for damage or improper installation. Determine whether the selected materials suit the process environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical interference:\u003c\/b\u003e Check for insufficient clearance between the housing, probe, shaft and nearby machine components, particularly after maintenance or alignment work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFor this order code, the critical purchasing distinction is that the housing configuration is listed with \u003cb\u003eno probe and no probe cable\u003c\/b\u003e. Before placing an order, compare the existing installation’s probe model, mounting thread, sleeve dimensions, rear conduit connection and sealing material with the requested assembly.\u003c\/p\u003e\n\n\u003cp\u003eIn a retrofit, photograph and document the installed probe orientation and cable route before dismantling. Once the housing is fitted, verify the probe’s physical clearance and measurement gap, then confirm the monitor channel returns a stable, correctly scaled signal. A housing that matches the thread alone may still be unsuitable if the sleeve geometry or probe arrangement differs.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eWarranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12-month warranty, subject to applicable supplier terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping options:\u003c\/b\u003e FedEx, UPS and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch timing:\u003c\/b\u003e Confirmed after stock and order verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompatibility review:\u003c\/b\u003e Share the full order code, probe model and installation dimensions when requesting a quotation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003e1. Does this exact configuration include the proximity probe?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied code legend identifies “00” as no probe, and the cable field “00” as no probe cable. Confirm the supplier’s bill of materials before ordering, especially because the source legend’s first option wording is ambiguous.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e2. Can I reuse the probe from my existing housing?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003ePossibly, but first verify that the probe is the correct reverse-mount type and that its dimensions, thread, connector, cable and electrical characteristics match the housing and monitoring channel. Check the probe’s condition and calibration requirements before reuse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e3. How do I determine whether the 2-inch sleeve is the right length?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the current installation’s sleeve length, mounting depth, probe reach and required clearance to the target. Use the machine drawing and probe installation instructions; do not choose sleeve length based only on the housing’s external appearance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e4. What should I verify if the housing fits but the vibration reading is incorrect?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the probe gap and orientation, target surface, mechanical rigidity, cable and connector integrity, and monitor channel configuration. A correct housing thread does not guarantee correct probe positioning or measurement calibration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e5. Is the Viton O-ring option suitable for every process environment?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Confirm chemical compatibility and operating-temperature limits for the actual medium and site conditions. If the environment is outside the seal material’s rating, consult the equipment documentation for an appropriate approved configuration.\u003c\/p\u003e\n","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67716366598326,"sku":"164818-00-20-020-01-01-01-00","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/164818.jpg?v=1792641418","url":"https:\/\/www.plcsparehub.com\/products\/164818-00-20-020-01-01-01-00-bently-nevada-proximity-probe-housing","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}