{"product_id":"15f5m1e-35ga-keb-combivert-f5-servo-drive-inverter-11kw","title":"15F5M1E-35GA KEB COMBIVERT F5 Servo Drive Inverter 11kW","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e15F5M1E-35GA\u003c\/strong\u003e\u003c\/span\u003e is a high-performance closed-loop drive controller from the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eKEB COMBIVERT F5\u003c\/strong\u003e\u003c\/span\u003e series.\u003c\/p\u003e\n\u003cp\u003eThis universal servo drive provides precise velocity, torque, and position control for synchronous and asynchronous AC motors.\u003c\/p\u003e\n\u003cp\u003eIt processes dynamic motor feedback including Resolvers, Incremental Encoders, Sin\/Cos, Absolute Encoders, Hiperface, and EnDat systems.\u003c\/p\u003e\n\u003cp\u003eIndustrial engineers integrate this drive into complex automated machinery to offload motion tasks from host PLCs.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eConfiguration \u0026amp; Variant Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e15F5M1E-35GA\u003c\/strong\u003e\u003c\/span\u003e (KEB COMBIVERT F5 System Platform)\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e15\u003c\/strong\u003e (Power Rating Identifier)\n        \u003cul\u003e\n          \u003cli\u003e11 kW motor shaft power rating (17 kVA power capability).\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eF5\u003c\/strong\u003e (Product Series Generation)\n        \u003cul\u003e\n          \u003cli\u003eAdvanced open and closed-loop frequency inverter architecture.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eM (MULTI Variant Class)\u003c\/strong\u003e\n        \u003cul\u003e\n          \u003cli\u003eField-oriented closed-loop control algorithm (F5-M) for dynamic vector performance.\u003c\/li\u003e\n          \u003cli\u003eSupports plug-in feedback interfaces (Resolver, TTL\/HTL, Sin\/Cos, Absolute, Hiperface, EnDat).\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHousing E Frame Size\u003c\/strong\u003e\n        \u003cul\u003e\n          \u003cli\u003eCompact enclosure footprint with integrated internal braking chopper module.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBrand Name\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eKEB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e15F5M1E-35GA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eKEB COMBIVERT F5\u003c\/strong\u003e\u003c\/span\u003e MULTI Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 kW (15 HP) 2-pole \/ 4-pole motor output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApparent Output Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 A \/ 21 A continuous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-Phase 305-500 VAC ±0% or 420-720 VDC ±0% DC bus input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-Phase 0-480 VAC proportional to input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 Hz to 408 Hz (F5-M mode) \/ up to 1600 Hz (open loop)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitching Frequencies\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProgrammable up to 16 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Terminals \u0026amp; I\/O\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29 plug-in terminals, 2 analog in, 2 analog out, 8 digital in, 2 relay out, 2 transistor out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Sampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh-dynamic sampling in less than 2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating \u0026amp; Cooling\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20 enclosure rating with heatsink fan cooling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e290 mm (H) x 130 mm (W) x 208 mm (D) (11.4 in x 5.1 in x 8.19 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 kg (11.0 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTarget Machinery \u0026amp; Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCNC Machining Centers:\u003c\/strong\u003e Drives high-speed spindles and servo axes demanding precise vector speed regulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated Packaging Equipment:\u003c\/strong\u003e Executes electronic camming, rotary indexing, and synchronized flying shear motion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling Systems:\u003c\/strong\u003e Manages high-torque hoist lifts and automated storage and retrieval system (ASRS) shuttles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTextile \u0026amp; Converting Machinery:\u003c\/strong\u003e Maintains tight web tension using integrated closed-loop torque control algorithms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; System Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeedback Fault Detection:\u003c\/strong\u003e Real-time monitoring of encoder channel loss, wire breaks, and signal phase errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectronic Thermal Protection:\u003c\/strong\u003e Evaluates internal motor PTC thermistors and calculates I²t thermal overload curves.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower-Off Braking Management:\u003c\/strong\u003e Controlled ramp stop and DC braking routines safeguard hardware during utility power loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDecentralized Motion Logic:\u003c\/strong\u003e Internal software parameter sets handle positioning loops without requiring central PLC intervention.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Interoperability \u0026amp; Feedback Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports asynchronous induction motors and permanent magnet synchronous AC servo motors.\u003c\/li\u003e\n  \u003cli\u003ePlug-in encoder cards interface with TTL\/HTL incremental, Sin\/Cos, Hiperface, EnDat, and Resolver sensors.\u003c\/li\u003e\n  \u003cli\u003eIncludes integrated braking chopper circuit for direct dynamic braking resistor connection.\u003c\/li\u003e\n  \u003cli\u003eFeatures ± intermediate DC bus connections for shared energy regeneration across multi-drive configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Setup Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit vertically on a smooth, flat backplate to maintain uninhibited vertical airflow.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum clearance of 100 mm above and below the drive housing for convective heat dissipation.\u003c\/li\u003e\n  \u003cli\u003eConnect motor leads using shielded power cables and bond shields directly to the drive ground clamp.\u003c\/li\u003e\n  \u003cli\u003eWire control signals separately from three-phase AC input lines to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e15F5M1E-35GA\u003c\/strong\u003e\u003c\/span\u003e remains a workhorse drive across automated bottling lines.\u003c\/p\u003e\n\u003cp\u003eField experience indicates that encoder feedback card seated improperly causes sporadic velocity feedback trips.\u003c\/p\u003e\n\u003cp\u003eDuring a line overhaul, our engineers resolved intermittent overcurrent alarms by resetting the internal encoder plug interface.\u003c\/p\u003e\n\u003cp\u003eVerifying motor PTC sensor resistance directly at the control terminal block prevents unnecessary thermal shutdown faults.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Purchasing Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that your motor nominal current does not exceed the drive output rating of 24 A continuous.\u003c\/li\u003e\n  \u003cli\u003eConfirm the required feedback option card (Resolver, Incremental, EnDat) matches your motor transducer hardware.\u003c\/li\u003e\n  \u003cli\u003eCheck if external braking resistors are required for high-inertia deceleration cycles.\u003c\/li\u003e\n  \u003cli\u003eEnsure line reactor filtering is present on power lines with unstable ambient AC supply voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents, Logistics \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e 1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e15F5M1E-35GA\u003c\/strong\u003e\u003c\/span\u003e Servo Drive Controller Module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Backed by a full 12-month standard industrial replacement warranty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcessing Time:\u003c\/strong\u003e Standard stock units ship out within 24 to 48 hours following order confirmation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpress Delivery:\u003c\/strong\u003e Express international dispatch available via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat distinguishes the COMBIVERT F5 MULTI drive series from BASIC and COMPACT models?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MULTI series incorporates closed-loop field-oriented control cards supporting feedback options like Resolvers and EnDat encoders.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this drive operate directly off a DC bus supply instead of three-phase AC mains?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the intermediate DC circuit accepts 420-720 VDC directly across the positive and negative bus connections.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do technicians reset drive parameter sets back to factory default values?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccess parameter CP.28 using the pluggable keypad module and set the value to restore factory defaults.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich parameter controls maximum switching frequency to minimize audible motor noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjust parameter uF.00 up to 16 kHz to reduce motor hum, taking drive derating factors into consideration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat safety pre-check prevents internal dynamic braking chopper circuit damage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure dynamic braking resistor resistance to ensure it meets minimum ohm ratings before applying power.\u003c\/p\u003e","brand":"KEB","offers":[{"title":"Default Title","offer_id":45326127497398,"sku":"15F5M1E-35GA","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/15F5M1E-35GA.jpg?v=1785922185","url":"https:\/\/www.plcsparehub.com\/products\/15f5m1e-35ga-keb-combivert-f5-servo-drive-inverter-11kw","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}