{"product_id":"146824-0050-bently-nevada-cylinder-pressure-transducer-cable","title":"146824-0050 Bently Nevada Cylinder Pressure Transducer Cable","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ad1457;\"\u003e146824-0050\u003c\/span\u003e Bently Nevada Cylinder Pressure Transducer Cable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ad1457;\"\u003e\u003cstrong\u003e146824-0050\u003c\/strong\u003e\u003c\/span\u003e is a high-reliability signal transmission cable engineered for \u003cspan style=\"color: #ad1457;\"\u003e\u003cstrong\u003eBently Nevada cylinder pressure monitoring systems\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eThis cable assembly supports stable pressure signal acquisition in demanding industrial environments. It targets reciprocating compressors, gas engines, and high-pressure process equipment.\u003c\/p\u003e\n\u003cp\u003eThe design emphasizes signal integrity, thermal stability, and vibration resistance. Its rugged construction supports long-term operation in harsh process conditions.\u003c\/p\u003e\n\u003cp\u003eManufactured in the U.S.A., this model integrates with advanced combustion and cylinder pressure analysis platforms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ad1457;\"\u003e146824-0050\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e146824 = Cylinder Pressure Transducer Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0050 = 50 ft (15.2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Performance Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Measurement Capability\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSupports pressure ranges from 100 psia to 10,000 psia\u003c\/li\u003e\n\u003cli\u003eCompatible with 6.8 bar to 689 bar applications\u003c\/li\u003e\n\u003cli\u003eProof pressure rating reaches 1.5× full scale\u003c\/li\u003e\n\u003cli\u003eBurst pressure reaches 3× full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Output Characteristics\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eFull scale output: 10 ± 0.3 Vdc\u003c\/li\u003e\n\u003cli\u003eZero signal: 0.5 ± 0.1 Vdc\u003c\/li\u003e\n\u003cli\u003ePower supply range: 18 to 30 Vdc\u003c\/li\u003e\n\u003cli\u003eMaximum current consumption below 15 mA\u003c\/li\u003e\n\u003cli\u003eFrequency response: 0 Hz to 5500 Hz ±1 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Stability\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLinearity, hysteresis, and repeatability within ±0.3% FS\u003c\/li\u003e\n\u003cli\u003eThermal shift optimized across compensated temperature range\u003c\/li\u003e\n\u003cli\u003eStable response during continuous pressure cycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eElectronics housing temperature: -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003eSensor head temperature: -40°C to +150°C\u003c\/li\u003e\n\u003cli\u003eHumidity tolerance up to 95% condensing\u003c\/li\u003e\n\u003cli\u003eIP67 enclosure protection\u003c\/li\u003e\n\u003cli\u003eMaximum installation altitude: 2000 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eC-276 welded sensing structure\u003c\/li\u003e\n\u003cli\u003e316L stainless steel body construction\u003c\/li\u003e\n\u003cli\u003eGold-plated surfaces per MIL-G-45204 Type III Grade A\u003c\/li\u003e\n\u003cli\u003eIndustrial corrosion-resistant design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eO-Ring Media Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHifluor (Black)\u003c\/td\u003e\n\u003ctd\u003eHydrogen sulfide, petroleum oil, turbine oil, propane, natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthylene Propylene (Purple)\u003c\/td\u003e\n\u003ctd\u003eAmmonium hydroxide and anhydrous ammonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ad1457;\"\u003e\u003cstrong\u003e146824-0050\u003c\/strong\u003e\u003c\/span\u003e performs especially well in high-speed reciprocating compressor systems. Its high-frequency response captures fast combustion and pressure fluctuations accurately.\u003c\/p\u003e\n\u003cp\u003eThe robust housing materials improve long-term durability in corrosive gas applications. Field engineers often deploy this model in refinery and gas compression facilities.\u003c\/p\u003e\n\u003cp\u003eCompared with general-purpose industrial cables, this configuration delivers stronger signal consistency during cyclic pressure events. The design supports advanced diagnostics and predictive maintenance programs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRecommended Equipment Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReciprocating gas compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial gas engines\u003c\/li\u003e\n\u003cli\u003eCombustion monitoring systems\u003c\/li\u003e\n\u003cli\u003eCylinder pressure analysis platforms\u003c\/li\u003e\n\u003cli\u003eProcess pressure monitoring equipment\u003c\/li\u003e\n\u003cli\u003ePipeline gas compression systems\u003c\/li\u003e\n\u003cli\u003eEnergy production machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDynamic combustion pressure monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-speed compressor diagnostics\u003c\/li\u003e\n\u003cli\u003eCylinder balance analysis\u003c\/li\u003e\n\u003cli\u003eEngine efficiency optimization projects\u003c\/li\u003e\n\u003cli\u003ePressure pulsation monitoring systems\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance programs\u003c\/li\u003e\n\u003cli\u003eHazardous industrial process areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports cylinder pressure waveform analysis\u003c\/li\u003e\n\u003cli\u003eDetects abnormal combustion patterns\u003c\/li\u003e\n\u003cli\u003eIdentifies valve leakage conditions\u003c\/li\u003e\n\u003cli\u003eHelps evaluate compressor load balance\u003c\/li\u003e\n\u003cli\u003eSupports transient pressure event monitoring\u003c\/li\u003e\n\u003cli\u003eImproves rotating equipment reliability analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area and Compliance Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFCC Part 15 compliant\u003c\/li\u003e\n\u003cli\u003eEN 61326-1 EMC compliant\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003eATEX Directive 2014\/34\/EU certified\u003c\/li\u003e\n\u003cli\u003eIECEx hazardous area approved\u003c\/li\u003e\n\u003cli\u003eClass I Division 1 certified\u003c\/li\u003e\n\u003cli\u003eClass I Division 2 certified\u003c\/li\u003e\n\u003cli\u003eEx ia IIC T4 Ga certified\u003c\/li\u003e\n\u003cli\u003eEx nA IIC T4 Gc certified\u003c\/li\u003e\n\u003cli\u003eEx ec IIC T4 Gc certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical and Installation Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 3.175 cm × 3.175 cm × 3 cm\u003c\/li\u003e\n\u003cli\u003eTotal assembly weight: 0.25 kg\u003c\/li\u003e\n\u003cli\u003eSensor head weight: 150 g\u003c\/li\u003e\n\u003cli\u003eRecommended mounting torque: 68 N·m\u003c\/li\u003e\n\u003cli\u003eDesigned for industrial vibration environments\u003c\/li\u003e\n\u003cli\u003eSupports direct integration with pressure transducer assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory original industrial packaging\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12-month warranty support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eFast dispatch within 24–48 hours\u003c\/li\u003e\n\u003cli\u003eGlobal delivery service available\u003c\/li\u003e\n\u003cli\u003eShipping supported by FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eProtective export packaging included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does frequency response matter in cylinder pressure analysis?\u003c\/strong\u003e\n\u003cp\u003eHigher frequency response improves detection of rapid combustion and pulsation events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow should engineers choose the correct pressure range?\u003c\/strong\u003e\n\u003cp\u003eSelect a range slightly above normal operating pressure to maintain measurement accuracy and safety margin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich sealing material suits natural gas applications?\u003c\/strong\u003e\n\u003cp\u003eHifluor O-rings perform well in hydrocarbon and natural gas operating environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat installation issue commonly affects pressure signal stability?\u003c\/strong\u003e\n\u003cp\u003eImproper torque application may introduce sealing inconsistencies and unstable pressure readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is IP67 protection important for field installations?\u003c\/strong\u003e\n\u003cp\u003eIt improves reliability in humid, dusty, and outdoor industrial process environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/146824.png?v=1779257378\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013804515510,"sku":"146824-0050","price":324.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/146824-0050.jpg?v=1779257487","url":"https:\/\/www.plcsparehub.com\/products\/146824-0050-bently-nevada-cylinder-pressure-transducer-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}