{"product_id":"140ddo35300-modicon-quantum-24v-dc-solid-state-output-module-in-stock","title":"140DDO35300 Modicon Quantum 24V DC Solid State Output Module In Stock","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eSchneider Electric\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e140DDO35300\u003c\/strong\u003e delivers 32 solid-state 24 V DC outputs.\u003c\/p\u003e\n\u003cp\u003eControl engineers deploy this high-density sourcing card for demanding industrial switching tasks.\u003c\/p\u003e\n\u003cp\u003eThe module organizes channels into four isolated groups of eight outputs each.\u003c\/p\u003e\n\u003cp\u003eFast switching circuits ensure reliable operation across complex automation environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem Parameter Group\u003c\/th\u003e\n\u003cth\u003eTechnical Attribute\u003c\/th\u003e\n\u003cth\u003eAttribute Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Hardware Architecture\u003c\/td\u003e\n\u003ctd\u003eBrand \u0026amp; Product Line\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eSchneider Electric\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/modicon-quantum-series\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Hardware Architecture\u003c\/td\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003e140DDO35300\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Hardware Architecture\u003c\/td\u003e\n\u003ctd\u003eModule Format \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum Slot \/ 0.99 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eChannel Count \u0026amp; Output Logic\u003c\/td\u003e\n\u003ctd\u003e32 Sourcing Channels (Positive Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal (19.2 V DC to 30 V DC limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e16 A per module \/ 4 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eMaximum Voltage Drop \u0026amp; Leakage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.4 V at 0.5 A load \/ 0.4 mA maximum at 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eSurge Current \u0026amp; Pulse Rating\u003c\/td\u003e\n\u003ctd\u003e5 A for 0.0005 s \/ 56 V 1.3 s decaying pulse max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Dynamics \u0026amp; Dissipation\u003c\/td\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e2 Output Data Words (32 bits total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Dynamics \u0026amp; Dissipation\u003c\/td\u003e\n\u003ctd\u003eResponse Time \u0026amp; Backplane Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms turn-on or turn-off \/ 330 mA bus current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Dynamics \u0026amp; Dissipation\u003c\/td\u003e\n\u003ctd\u003ePower Dissipation Formula\u003c\/td\u003e\n\u003ctd\u003e1.75 W + (0.4 V x total module load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Isolation Limits\u003c\/td\u003e\n\u003ctd\u003eChannel Fusing Protection\u003c\/td\u003e\n\u003ctd\u003e3 A rating each point \/ 5 A per group internal fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Isolation Limits\u003c\/td\u003e\n\u003ctd\u003eIsolation Breakdown Rating\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms DC to bus \/ 500 Vrms DC between groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; ESD Endurance\u003c\/td\u003e\n\u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e32°F to 140°F (0°C to 60°C) \/ -40°F to 185°F (-40°C to 85°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; ESD Endurance\u003c\/td\u003e\n\u003ctd\u003eNoise \u0026amp; Electrostatic Immunity\u003c\/td\u003e\n\u003ctd\u003e4 kV contact \/ 8 kV air ESD \/ 10 V\/m field resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off backplane power before sliding the module into the rack slot.\u003c\/li\u003e\n\u003cli\u003eAlign top and bottom module guide rails carefully with the Quantum backplane card cage.\u003c\/li\u003e\n\u003cli\u003eConnect external 24 V DC field power supplies to terminal blocks supplying each channel group.\u003c\/li\u003e\n\u003cli\u003eEnsure field wiring gauge supports max group current up to 4 Amperes continuous load.\u003c\/li\u003e\n\u003cli\u003eTighten field connector screws to guarantee low-resistance electrical connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify external 24 V DC power supply presence before enabling PLC logic execution.\u003c\/li\u003e\n\u003cli\u003eCheck green active LED status to confirm backplane communications function correctly.\u003c\/li\u003e\n\u003cli\u003eObserve individual channel status LEDs during automated output forced testing steps.\u003c\/li\u003e\n\u003cli\u003eReplace blown group fuses immediately using rated 5 Amp fast-acting fuse units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Software Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates into standard \u003cstrong style=\"color: #0056b3;\"\u003eSchneider Electric\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e rack slots.\u003c\/li\u003e\n\u003cli\u003eConfigures easily within EcoStruxure Control Expert (Unity Pro) software suites.\u003c\/li\u003e\n\u003cli\u003eSupports legacy Concept and ProWORX 32 programming and configuration environments.\u003c\/li\u003e\n\u003cli\u003eCommunicates seamlessly with Modicon Quantum CPU controllers across backplane buses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 508 standard for industrial control equipment safety compliance.\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142 certified for industrial products in North America.\u003c\/li\u003e\n\u003cli\u003eCE marked for European electromagnetic compatibility directives.\u003c\/li\u003e\n\u003cli\u003eFM Class 1 Division 2 approved for non-incendive hazardous location operations.\u003c\/li\u003e\n\u003cli\u003eMarine certified by ABS, BV, DNV, GL, RINA, and RMRS classification societies.\u003c\/li\u003e\n\u003cli\u003eC-tick and GOST approved for global industrial distribution markets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment \u0026amp; Typical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated packaging systems driving high-speed solenoid actuator manifolds.\u003c\/li\u003e\n\u003cli\u003eWater treatment plants controlling 24 V DC interposing relay banks.\u003c\/li\u003e\n\u003cli\u003eConveyor sorters activating pneumatic cylinder switches in logistics hubs.\u003c\/li\u003e\n\u003cli\u003eContinuous process plants switching discrete alarm light indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Fault Detection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRed front panel LED lights up instantly upon external fault detection.\u003c\/li\u003e\n\u003cli\u003eSystem automatically senses blown group fuses and reports diagnostic flags.\u003c\/li\u003e\n\u003cli\u003eDetects loss of field power supplies across individual channel groups in real time.\u003c\/li\u003e\n\u003cli\u003eGreen logic LEDs indicate clear visual feedback for all 32 output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Logistics \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLogistics Attribute\u003c\/th\u003e\n\u003cth\u003eService Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Physical Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.24 in x 6.47 in x 1.81 in (31.09 cm x 16.44 cm x 4.59 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Package Weight\u003c\/td\u003e\n\u003ctd\u003e15.3 oz (434.9 g) total packaged mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComprehensive Warranty Term\u003c\/td\u003e\n\u003ctd\u003e12 Months complete coverage period\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Dispatch Timeline\u003c\/td\u003e\n\u003ctd\u003eStandard shipment within 24 to 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Courier Shipping Options\u003c\/td\u003e\n\u003ctd\u003eExpress delivery options available worldwide via FedEx, UPS, and DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring a high-speed bottling plant setup, inductive kickback from unsuppressed solenoid coils repeatedly blew channel fuses.\u003c\/p\u003e\n\u003cp\u003eOur field team analyzed the total inductive load using the module equation L = 0.5 \/ (I^2 x f).\u003c\/p\u003e\n\u003cp\u003eWe installed external flyback diodes across heavy solenoid loads while replacing blown group fuses.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e140DDO35300\u003c\/strong\u003e restored flawless 24\/7 output operation without further field power loss.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How do engineers calculate inductive load limits for the \u003cstrong style=\"color: #0056b3;\"\u003e140DDO35300\u003c\/strong\u003e outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Use the mathematical formula L = 0.5 \/ ((current in Amperes)^2 x switching frequency in Hz).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What visual indication shows loss of field power on output groups?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The red LED labeled F illuminates on the front panel to indicate field power loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What key parameters should buyers verify when ordering replacement output cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Check field power voltage requirements, positive sourcing logic compatibility, channel density, and group fusing ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Why does thermal dissipation rise when operating high current loads on all channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Internal resistance causes heat buildup calculated as 1.75 W plus 0.4 V multiplied by total current load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How many data words does the CPU controller allocate for this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The Quantum backplane system automatically assigns two 16-bit output data words to control all 32 points.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45013803794614,"sku":"140DDO35300","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/140DDO35300_1.jpg?v=1786946719","url":"https:\/\/www.plcsparehub.com\/products\/140ddo35300-modicon-quantum-24v-dc-solid-state-output-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}