{"product_id":"128987-130-01-05-proximity-sensor-system-cable-bently-nevada-3300-xl","title":"128987-130-01-05 Proximity Sensor System Cable Bently Nevada 3300 XL","description":"\u003ch3\u003e\u003cstrong\u003eInterconnect Function \u0026amp; System Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 128987-130-01-05\u003c\/strong\u003e is a precision coaxial interconnect engineered for \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL 8 mm\u003c\/strong\u003e eddy-current proximity transducer systems. Designed to maintain strict electrical impedance matching between the sensing probe and the Proximitor oscillator, this assembly preserves signal fidelity across a 0 to 10 kHz frequency band. Built for continuous operation in high-humidity and elevated-temperature rotating machinery environments, the \u003cstrong style=\"color: #0056b3;\"\u003e128987-130-01-05\u003c\/strong\u003e carries multi-agency hazardous area approvals for critical turbine, compressor, and pump protection loops.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOrdering Code \u0026amp; Configuration Tree\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery suffix segment in the \u003cstrong style=\"color: #0056b3;\"\u003e128987-130-01-05\u003c\/strong\u003e part string establishes exact physical length, mechanical armor, and regulatory compliance:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Series Code:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e128987\u003c\/strong\u003e — 3300 XL 8 mm Proximity Sensor System Interconnect Base\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLength Specifier (-130):\u003c\/strong\u003e Dedicated 13.0-metre (42.7-foot) electrical cable length configuration\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eArmor \/ Cable Option (-01):\u003c\/strong\u003e Coaxial cable construction option tailored for industrial mechanical routing\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAgency Approval (-05):\u003c\/strong\u003e Multiple hazardous location certifications (CSA, ATEX, IECEx compliant)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eElectromechanical \u0026amp; Environmental Specification Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Product Line\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e — \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL 8 mm\u003c\/strong\u003e Proximity System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003e128987-130-01-05\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximity Sensor System Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 mV\/mil (7.87 V\/mm) nominal system scale factor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Gap Span\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 mm to 2.5 mm operating target gap range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz dynamic vibration response\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e–18 VDC to –26 VDC oscillator input rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThermal Operating Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCable rating: –35°C to +150°C | Standard probe tip reference: –35°C to +125°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 100% relative humidity (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMultiple approvals (ATEX, IECEx, CSA via Option -05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Component Mass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRouting, Termination \u0026amp; Commissioning Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify Total Electrical System Length:\u003c\/strong\u003e Confirm that the combined probe and \u003cstrong style=\"color: #0056b3;\"\u003e128987-130-01-05\u003c\/strong\u003e cable length matches the exact calibrated length stamped on your Proximitor housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRespect Minimum Bend Radius:\u003c\/strong\u003e Route the coaxial cable smoothly around bearing pedestals without sharp kinks that alter center-conductor dielectric spacing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolate Coaxial Shields:\u003c\/strong\u003e Ensure the outer braided shield remains electrically isolated from machine ground along the entire run to prevent ground-loop hum.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeal External Junctions:\u003c\/strong\u003e Wrap external coaxial connectors with silicone self-fusing tape (outside oil-submerged sumps) to block moisture ingress in 100% RH environments.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty \u0026amp; Global Express Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e12-Month Operational Warranty:\u003c\/strong\u003e Every \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 128987-130-01-05\u003c\/strong\u003e cable includes a comprehensive 12-month warranty covering impedance stability and insulation integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePriority International Air Freight:\u003c\/strong\u003e Ready-to-ship inventory dispatches worldwide via \u003cstrong style=\"color: #0056b3;\"\u003eFedEx\u003c\/strong\u003e, \u003cstrong style=\"color: #0056b3;\"\u003eUPS\u003c\/strong\u003e, or \u003cstrong style=\"color: #0056b3;\"\u003eDHL\u003c\/strong\u003e express courier networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSpecify the \u003cstrong style=\"color: #0056b3;\"\u003e128987-130-01-05\u003c\/strong\u003e when replacing damaged interconnects or extending sensor runs to remote explosion-proof junction boxes in \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL 8 mm\u003c\/strong\u003e installations requiring CSA, ATEX, or IECEx compliance. Always verify whether your cabinet layout calls for standard flexible coaxial jacket or stainless-steel armored protection before finalizing procurement.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why is exact electrical cable length matching critical in eddy-current proximity systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The coaxial cable acts as a tuned capacitive element inside the Proximitor's high-frequency tank circuit; substituting a different cable length shifts the resonant frequency and skews the 200 mV\/mil sensitivity curve.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can technicians cut and re-terminate a damaged connector on the 128987-130-01-05 cable in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Field trimming is strongly discouraged because altering physical length changes total distributed capacitance, and non-factory crimps introduce impedance reflections across the 0 to 10 kHz bandwidth.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How do I check if moisture or oil has migrated inside the coaxial dielectric during troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Disconnect both ends of the cable and measure insulation resistance between the center pin and outer shell using a low-voltage ohmmeter; any reading below infinite open-circuit indicates dielectric contamination.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: What is the practical benefit of ordering the -05 multiple agency approval option for plant spare stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Stocking the -05 certified variant allows maintenance teams to deploy a single spare part across both general-purpose safe areas and Class I Zone 1\/2 or Division 1\/2 hazardous locations without audit discrepancies.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What causes erratic spikes on a 3300 XL vibration channel when the cable passes near high-horsepower VFD feeders?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Routing low-level coaxial transducer cables parallel to unshielded motor power leads couples switching noise onto the shield; maintain at least 300 mm separation or route inside dedicated grounded steel conduit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013936570550,"sku":"128987-130-01-05","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/128987_2_b00ad899-cddd-49a5-be09-d8c47cbbcffb.jpg?v=1794819757","url":"https:\/\/www.plcsparehub.com\/products\/128987-130-01-05-proximity-sensor-system-cable-bently-nevada-3300-xl","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}