{"product_id":"10f5a1d-3aga-keb-combivert-f5-2-2kw-400v-ac-drive-fast-shipping","title":"10F5A1D-3AGA KEB Combivert F5 2.2kW 400V AC Drive Fast Shipping","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eKEB Combivert F5 Multi Frequency Inverter Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e10F5A1D-3AGA\u003c\/strong\u003e is a high-precision multi-frequency inverter belonging to the KEB Combivert F5 series. Engineered for controlled AC motor operations, this unit delivers 4.0 kVA power output at 400V AC 3-phase, supporting continuous motor loads up to 2.2 kW (3 HP) with a rated current of 5.8A.\u003c\/p\u003e\n\u003cp\u003eIt features integrated dual TTL incremental encoder inputs for closed-loop vector control, an internal GTR7 braking transistor for rapid dynamic deceleration, and an air-cooled heat sink structure inside a compact IP20 housing.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSpecifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003e\u003cspan style=\"color: #1a252c; font-weight: bold;\"\u003eParameter Category\u003c\/span\u003e\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003e\u003cspan style=\"color: #1a252c; font-weight: bold;\"\u003eTechnical Specification\u003c\/span\u003e\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eModel Code\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #d9534f; font-weight: bold;\"\u003e10F5A1D-3AGA\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eProduct Series \u0026amp; Type\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eKEB Combivert F5 Controlled Frequency Inverter\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eApparent Power Rating\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e4.0 kVA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eMotor Shaft Rating\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #28a745; font-weight: bold;\"\u003e2.2 kW (3 HP) \/ 2 or 4 Pole (50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eInput Supply Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e305 to 528 V AC, 3 Phase, 50\/60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eOutput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0 to Uin (3 Phase)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eNominal Output Current\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #28a745; font-weight: bold;\"\u003e5.8 A continuous\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003ePeak Short-Time Current\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10.4 A limit\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eMaximum Frequency Output\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUp to 599 Hz \/ 800 Hz output limits\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eCarrier Switching Frequency\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e8 kHz default\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eEncoder Interfaces\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDual incremental TTL inputs (Channel 1 \u0026amp; Channel 2)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eIntegrated Braking Hardware\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eGTR7 Brake Transistor Chopper\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eCooling \u0026amp; Enclosure\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAir cooler heat sink, IP20 physical rating\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e90 mm (W) x 250 mm (H) x 181 mm (D)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Target Applications \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Compatibility \u0026amp; Real-Time Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Equipment:\u003c\/strong\u003e High-speed CNC spindles, positioning tables, packaging conveyors, textile spinning machines, and dynamic lift mechanism drives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Encoder Feedback Handling:\u003c\/strong\u003e Interface 1 and 2 accept differential RS422\/TTL incremental feedback, allowing dual-loop velocity monitoring or master-slave speed synchronization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Trip tracking triggers instantaneous shutdown when output exceeds the 10.4A threshold to safeguard IGBT power modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Dissipation Monitoring:\u003c\/strong\u003e Onboard heat sink sensors trigger air cooling fan regulation and thermal fault reporting prior to junction damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBraking Circuit Supervision:\u003c\/strong\u003e Integrated GTR7 chopper continuously measures DC bus overvoltage during regenerative deceleration phases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Field Observations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe \u003cstrong\u003e10F5A1D-3AGA\u003c\/strong\u003e remains a benchmark for compact 2.2kW closed-loop VFD replacements due to its onboard dual TTL channels.\u003c\/li\u003e\n  \u003cli\u003eIts 90mm slim footprint allows high-density side-by-side mounting inside crowded control enclosures.\u003c\/li\u003e\n  \u003cli\u003eThe GTR7 braking transistor simplifies high-duty cycle stopping applications without needing external chopper units—only an external resistor bank is required.\u003c\/li\u003e\n  \u003cli\u003eOperating at an 8kHz switching frequency balances low acoustic motor noise with manageable thermal losses on the heat sink.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFulfillment \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal Logistics \u0026amp; Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCovered under a comprehensive \u003cspan style=\"color: #d9534f; font-weight: bold;\"\u003e12-month functional warranty\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003eWorldwide expedited shipping handled via \u003cspan style=\"color: #d9534f; font-weight: bold;\"\u003eFedEx, UPS, and DHL\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003eDispatched with protective ESD-safe packaging and physical quality check reports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Selection \u0026amp; Operational Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eQ: How do you configure dual encoders on this VFD variant?\u003cbr\u003e\nA: TTL incremental encoders plug directly into Interfaces 1 and 2; channel scaling and impulse counts must be configured in the F5 parameter tree to match motor PPR settings.\u003c\/p\u003e\n\u003cp\u003eQ: What size braking resistor should be paired with the internal GTR7 transistor?\u003cbr\u003e\nA: Select a resistor value based on the DC bus voltage threshold and peak power rating, ensuring minimum resistance limits stated in the technical manual are maintained.\u003c\/p\u003e\n\u003cp\u003eQ: Can this drive operate standard asynchronous induction motors without encoder feedback?\u003cbr\u003e\nA: Yes, it supports open-loop V\/f and sensorless vector control modes alongside its closed-loop TTL capabilities.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are necessary when operating near the 599Hz output limit?\u003cbr\u003e\nA: High-frequency operation requires verifying motor insulation ratings, de-rating output current for high switching frequencies, and minimizing output cable length.\u003c\/p\u003e\n\u003cp\u003eQ: What thermal clearance is required around the air cooler housing?\u003cbr\u003e\nA: Maintain at least 100mm clearance above and below the 90x250x181mm chassis to ensure unrestricted vertical airflow through the heat sink fins.\u003c\/p\u003e","brand":"KEB","offers":[{"title":"Default Title","offer_id":45322244882614,"sku":"10F5A1D-3AGA","price":198.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/10F5A1D-3AGA.jpg?v=1785831891","url":"https:\/\/www.plcsparehub.com\/products\/10f5a1d-3aga-keb-combivert-f5-2-2kw-400v-ac-drive-fast-shipping","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}