{"product_id":"106m1081-01-bently-nevada-rack-power-input-module-3500-15","title":"106M1081-01 Bently Nevada Rack Power Input Module 3500\/15","description":"\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada \u003cspan style=\"color: #d12727;\"\u003e3500\/15-05-05\u003c\/span\u003e\u003c\/strong\u003e (Internal Part No. 106M1081-01) is the essential high-tier interface for the 3500 Machinery Protection System. This Universal AC Power Input Module (PIM) is engineered to rectify and filter incoming line voltage before it reaches the internal power supply module. Unlike legacy fixed-voltage units, the \u003cstrong\u003e\u003cspan style=\"color: #d12727;\"\u003e3500\/15-05-05\u003c\/span\u003e\u003c\/strong\u003e utilizes an auto-ranging front-end that accepts a broad spectrum from 85 to 264 Vac, making it a \"global\" spare. Engineering teams must note that this universal architecture is physically and electrically incompatible with legacy Low\/High Voltage AC supplies. When paired in the designated half-height rear slots, these modules facilitate true hardware redundancy, ensuring that a single-source power failure does not compromise critical vibration monitoring data on turbines or compressors.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e — [System Series] Power Supply Framework\u003c\/p\u003e\n\u003cp\u003e        └── \u003cstrong\u003e-05\u003c\/strong\u003e — [Supply Type] Universal AC (85 to 264 Vac rms)\u003c\/p\u003e\n\u003cp\u003e                └── \u003cstrong\u003e-05\u003c\/strong\u003e — [Agency Approval] Multi-regional Safety Certification\u003c\/p\u003e\n\u003cp\u003e                        └── \u003cstrong\u003e106M1081-01\u003c\/strong\u003e — [PIM Board] High-density AC Filter Assembly\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specification Matrix\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (Baker Hughes)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003e\u003cspan style=\"color: #d12727;\"\u003e3500\/15-05-05\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: \u003cstrong\u003e3500 Machinery Protection System\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 85 to 264 Vac rms (Auto-ranging)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 47 to 63 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Requirement\u003c\/strong\u003e: Half-height (Rear Rack Location)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy\u003c\/strong\u003e: Fully supported via dual PIM installation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.34 Kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Not compatible with legacy LV\/HV AC units\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplication Scenarios \u0026amp; System Pairing\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCritical Machinery Protection\u003c\/strong\u003e: The primary power gateway for 3500 racks monitoring steam turbines and compressors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Infrastructure\u003c\/strong\u003e: Ideal for plants requiring \"Hot-Standby\" power where two modules are installed in tandem.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Plant Standardization\u003c\/strong\u003e: Simplifies inventory for multinational fleets by supporting all standard AC grid voltages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefinery \u0026amp; Power Gen\u003c\/strong\u003e: Optimized for high-vibration, high-EMI environments typical of industrial facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDiagnostic \u0026amp; Integration Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActive Filtering\u003c\/strong\u003e: On-board surge suppression and EMI filtering to protect sensitive monitoring cards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Source Tracking\u003c\/strong\u003e: The PIM design allows the 3500\/01 Software to monitor the health of the power source.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy Validation\u003c\/strong\u003e: Logic-controlled load sharing when two modules are utilized for seamless transfer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Keying\u003c\/strong\u003e: Specific connector layouts prevent incorrect insertion into DC or legacy AC slots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal Logistics \u0026amp; Service Excellence\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Policy\u003c\/strong\u003e: Includes a full \u003cstrong\u003e12-month quality guarantee\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Shipping\u003c\/strong\u003e: Priority express delivery via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDispatch Window\u003c\/strong\u003e: Guaranteed fulfillment and shipment within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging\u003c\/strong\u003e: New and original, shipped in factory-grade protective anti-static materials.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection \u0026amp; Buying Guide\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFront\/Rear Alignment\u003c\/strong\u003e: This PIM (106M1081-01) must be used with the Universal AC Supply; it is not compatible with legacy units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUpgrade Requirements\u003c\/strong\u003e: If upgrading a legacy rack, you must replace both the front Supply and the rear PIM simultaneously.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpares Strategy\u003c\/strong\u003e: We recommend maintaining two units in stock to ensure the rack's redundancy capability is never compromised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the \u003cspan style=\"color: #d12727;\"\u003e3500\/15-05-05\u003c\/span\u003e compatible with DC power sources?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module is strictly designed for AC inputs (85-264 Vac). If your facility utilizes 24V or 125V DC, a different PIM variant is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I mix a Universal AC PIM with a legacy High Voltage AC PIM in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Mixing universal and legacy power components in the same rack is not supported and may lead to system damage or shutdowns.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 106M1081-01 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is the specific internal PCBA part number for the Universal AC Power Input Module, distinguishing it from older versions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does redundancy work if I only have one mains power source?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTrue redundancy is only achieved if each PIM is connected to a separate, independent AC circuit breaker or UPS system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this module require any jumpers or dip-switch settings for 110V vs 220V?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module is fully auto-ranging. It will automatically detect and adjust to any voltage within the 85 to 264 Vac range.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013799665846,"sku":"106M1081-01","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/106M1081-01_2.jpg?v=1775727404","url":"https:\/\/www.plcsparehub.com\/products\/106m1081-01-bently-nevada-rack-power-input-module-3500-15","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}