{"product_id":"106m1079-01-3500-15-05-05-00-bently-nevada-3500-power-supply","title":"106M1079-01 3500\/15-05-05-00 Bently Nevada 3500 Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eEngineering System Architecture \u0026amp; Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3500\/15-05-05-00\u003c\/strong\u003e (Spare Part Number: \u003cstrong style=\"color: #0056b3;\"\u003e106M1079-01\u003c\/strong\u003e) is an essential Universal AC Power Supply Module designed for the industry-leading \u003cstrong style=\"color: #0056b3;\"\u003e3500 Machinery Protection System\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module provides reliable, conditioned electrical power to all rack monitoring cards and interface modules, ensuring uninterrupted continuous plant surveillance.\u003c\/p\u003e\n\u003cp\u003eDesigned with dual-slot redundancy capability, it accommodates flexible top and bottom slot configurations to match specific rack load and safety requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePart Number Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; margin-left: 0; padding-left: 0; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3500\/15\u003c\/strong\u003e — Power Supply System\u003c\/li\u003e\n  \u003cli\u003e\n    \u003cul style=\"list-style-type: disc; margin-left: 20px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePower Supply Type - Top Slot (05):\u003c\/strong\u003e Universal AC Voltage (85 to 264 Vac rms)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePower Supply Type - Bottom Slot (05):\u003c\/strong\u003e Universal AC Voltage (85 to 264 Vac rms) — Dual Redundant Configuration\u003c\/li\u003e\n      \u003cdiv\u003e\n        \u003cul style=\"list-style-type: circle; margin-left: 20px;\"\u003e\n          \u003cli\u003e\n\u003cstrong\u003eAgency Approval Option (00):\u003c\/strong\u003e None (Standard non-hazardous configuration)\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eElectrical and Power Input Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003cth style=\"border: 1px solid #dee2e6; padding: 10px; text-align: left;\"\u003eElectrical Parameter\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #dee2e6; padding: 10px; text-align: left;\"\u003eEngineering Specification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eNominal Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e110 to 220 Vac nominal\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eOperating Voltage Range (Non-Hazardous)\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e85 to 264 Vac rms (120 to 373 Vac pk)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eOperating Voltage Range (Hazardous)\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e85 to 250 Vac rms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eInput Frequency Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e47 to 63 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eFull Rack Current Draw (Universal AC)\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e2.8 A rms maximum\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eOver-Voltage \u0026amp; Under-Voltage Protection\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eUnder-voltage causes no damage; over-voltage opens PIM fuse\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePhysical Dimensions and Weight Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: disc; margin-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Module Dimensions:\u003c\/strong\u003e 120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Module Weight:\u003c\/strong\u003e 1.39 kg (3.06 lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Input Module (PIM) Dimensions:\u003c\/strong\u003e 120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Input Module (PIM) Weight:\u003c\/strong\u003e 0.34 kg (0.75 lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFront Panel Status Indicator:\u003c\/strong\u003e Dedicated \"Supply OK\" LED confirms normal operational status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty, Logistics, and Fulfillment Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: disc; margin-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition \u0026amp; Packaging:\u003c\/strong\u003e Supplied 100% brand new and original in factory-sealed packaging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Warranty:\u003c\/strong\u003e Fully backed by a 12-month comprehensive operational warranty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Shipping Partners:\u003c\/strong\u003e Fast and secure worldwide delivery dispatched via FedEx, UPS, and DHL air express services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the \u003cstrong style=\"color: #0056b3;\"\u003e3500\/15-05-05-00\u003c\/strong\u003e module if an input voltage surge exceeds safety thresholds?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Severe over-voltage events safely trip the internal fuse located on the matching Power Input Module (PIM), protecting the main power supply circuitry from catastrophic damage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can universal AC modules be interchanged directly with legacy high or low voltage DC units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, universal AC power supplies and their corresponding PIMs are mechanically and electrically incompatible with legacy DC hardware variants.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of populating both top and bottom slots with universal AC supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Configuring dual redundant power supplies ensures continuous rack operation and uninterrupted machinery protection even if one power feed experiences a total failure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do technicians verify that the power module is functioning correctly inside an active rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Plant operators can inspect the front-panel \"Supply OK\" LED indicator, which illuminates continuously when internal DC rails operate within proper tolerances.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What selection guidance applies when choosing between AC and DC power modules for a new 3500 rack installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Always match your rack power option to your plant control room's available uninterruptible power distribution infrastructure (e.g., standard 110\/220 Vac plant mains versus 24 Vdc instrument buses).\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcurement and Engineering Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVerify your control cabinet line voltage and rack slot allocation before placing your order.\u003c\/p\u003e\n\u003cp\u003eEnsure your facility's power distribution meets the 47 to 63 Hz frequency requirement for stable operation.\u003c\/p\u003e\n\u003cp\u003eContact our industrial automation engineering sales desk today for official quotations, current stock levels, and expedited FedEx, UPS, or DHL shipping.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013935653046,"sku":"106M1079-01","price":254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/3500-15133292-01_3423b9d3-195e-4d7d-81de-9c6735d5b542.jpg?v=1794819881","url":"https:\/\/www.plcsparehub.com\/products\/106m1079-01-3500-15-05-05-00-bently-nevada-3500-power-supply","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}