{"product_id":"106765-04-bently-nevada-interconnect-cable-signal-extension-wire","title":"106765-04 Bently Nevada Interconnect Cable Signal Extension Wire","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003e106765-04\u003c\/span\u003e \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003eBently Nevada\u003c\/span\u003e \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003e106765\u003c\/span\u003e \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003eInterconnect Cable\u003c\/span\u003e bridges proximity probes and Proximitor sensors in machinery protection systems. Instrumentation engineers rely on this dedicated extension cable to maintain low signal attenuation across monitoring loops.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003e\u003cstrong\u003eOrdering Parameter\u003c\/strong\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cstrong\u003eSelected Suffix\u003c\/strong\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cstrong\u003eEngineering Definition\u003c\/strong\u003e\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eBase Model\u003c\/td\u003e\n    \u003ctd\u003e106765\u003c\/td\u003e\n    \u003ctd\u003eStandard Proximity Interconnect Cable Architecture\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLength Option\u003c\/td\u003e\n    \u003ctd\u003e04\u003c\/td\u003e\n    \u003ctd\u003eExact total cable length of 4 meters\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003e\u003cstrong\u003eSpecification Attribute\u003c\/strong\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cstrong\u003eOperational Parameter\u003c\/strong\u003e\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConductor Design\u003c\/td\u003e\n    \u003ctd\u003eHigh-frequency coaxial configuration with precision shielding\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n    \u003ctd\u003eEngineered for 3300 and 7200 series proximity transducer systems\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eImpedance Match\u003c\/td\u003e\n    \u003ctd\u003eControlled characteristic impedance to eliminate standing wave reflections\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eJacket Durability\u003c\/td\u003e\n    \u003ctd\u003eIndustrial-grade insulation resistant to oil, moisture, and mechanical wear\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEquipment Compatibility \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct cable length ensures system loop calibration remains within factory specifications. Review your enclosure layout before choosing extension options:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSelection Tip: Utilize the \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003e106765-04\u003c\/span\u003e 4-meter model when distance between the machine casing probe and the junction box requires an intermediate span.\u003c\/li\u003e\n  \u003cli\u003eSystem Matching: Always pair matching cable capacitance ratings with your specific Proximitor sensor calibration sheet to prevent offset errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Applications \u0026amp; Diagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTransmits high-frequency raw dynamic gap voltage signals from shaft displacement probes.\u003c\/li\u003e\n  \u003cli\u003eDeploys seamlessly in steam turbine skids, centrifugal compressors, and generator bearing housings.\u003c\/li\u003e\n  \u003cli\u003eMaintains signal integrity across vibration rack extensions to minimize common-mode electrical noise.\u003c\/li\u003e\n  \u003cli\u003eSupports continuous diagnostic monitoring of radial vibration, axial thrust, and eccentric shaft whip.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstrumentation technicians frequently encounter signal calibration shifts when mismatched cable lengths alter total loop capacitance. Our field engineering team recommends verifying that connector pins are free of oxidation during installation. Using factory-original \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003eBently Nevada\u003c\/span\u003e cabling ensures system calibration curves remain perfectly aligned without signal drift.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompliance, Warranty \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory Quality: 100% new and original equipment packed in factory containers.\u003c\/li\u003e\n  \u003cli\u003eQuality Warranty: Fully protected by a comprehensive 12-month industrial replacement warranty.\u003c\/li\u003e\n  \u003cli\u003eFulfillment Logistics: Rapid 24-48 hour global dispatch via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is matching the exact length of the \u003cspan style=\"color:#1d4ed8; font-weight:bold;\"\u003e106765-04\u003c\/span\u003e cable critical for Proximitor loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Eddy current transducer systems rely on specific total circuit capacitance; altering cable length without recalibrating can introduce measurement scale factor errors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I splice or shorten this coaxial cable in the field if it is too long?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, field splicing alters characteristic impedance and capacitance, which severely distorts dynamic vibration waveforms and ruins system accuracy.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What precautions should I take when routing this cable through heavy industrial machinery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Route the coaxial line away from high-voltage motor power cables and variable frequency drives to prevent electromagnetic interference induction.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I inspect connector degradation during routine plant shutdowns?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the miniature coaxial pin connections for signs of moisture ingress, thread wear, or bent center conductors using a magnifying scope.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the main operational difference between probe cables and interconnect extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Probe cables are permanently attached to the sensor tip, whereas interconnect cables bridge the gap between the probe connector and the remote Proximitor sensor.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013799502006,"sku":"106765-04","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/106765_5_cac6a651-5518-4795-b91c-37dcf05f8330.jpg?v=1789452818","url":"https:\/\/www.plcsparehub.com\/products\/106765-04-bently-nevada-interconnect-cable-signal-extension-wire","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}