{"product_id":"100630-82-89-50-01-bently-nevada-3300-xl-8-mm-proximity-probe","title":"100630-82-89-50-01 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 100630-82-89-50-01 — 3300 XL 8 mm Underwater Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 100630-82-89-50-01\u003c\/strong\u003e is a 3300 XL 8 mm underwater proximity probe designed for machinery-monitoring applications where the probe body may be submerged or exposed to fluids. Its sealed probe case and protective Tefzel tubing help protect the assembly in wet operating environments, while the miniature coaxial ClickLoc connector provides the specified connection interface.\u003c\/p\u003e\n\u003cp\u003eThis configuration has a 3\/8-24 UNF threaded case, an 8.2-inch unthreaded length, an 8.9-inch overall case length, and a 5.0 m cable. Selection requires more than checking probe length: engineers must verify the mating extension cable and Proximitor sensor, installation geometry, pressure conditions, fluid chemistry, temperature limits, and hazardous-area installation requirements.\u003c\/p\u003e\n\u003ch3\u003e01 | Configuration Breakdown — Read the Suffix Before Ordering\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFull part number:\u003c\/strong\u003e 100630-82-89-50-01\u003c\/p\u003e\n\u003cblockquote\u003e100630 — 82 — 89 — 50 — 01\u003c\/blockquote\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100630 | Probe family and construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada 3300 XL 8 mm underwater proximity probe.\u003c\/li\u003e\n\u003cli\u003e3\/8-24 UNF thread with sealed case and Tefzel tubing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e82 | Unthreaded length\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e8.2 inches.\u003c\/li\u003e\n\u003cli\u003eLength options are specified in 0.1-inch increments.\u003c\/li\u003e\n\u003cli\u003eFamily configuration range: 0.8 to 9.6 inches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e89 | Overall case length\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e8.9 inches.\u003c\/li\u003e\n\u003cli\u003eSpecified as the overall case length option for this configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 | Total cable length\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e5.0 m (16.4 ft).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01 | Connector and cable type\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature coaxial ClickLoc connector with connector protector.\u003c\/li\u003e\n\u003cli\u003eStandard cable configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering control:\u003c\/strong\u003e Match the entire suffix, not just the 100630 family number. The length and connector options affect mechanical installation and the electrical measurement chain.\u003c\/p\u003e\n\u003ch3\u003e02 | Technical Specification Register\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003e8 mm underwater proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull part number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100630-82-89-50-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase probe number\u003c\/td\u003e\n\u003ctd\u003e100630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe construction\u003c\/td\u003e\n\u003ctd\u003eSealed case with Tefzel tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003e8.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e8.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal cable length\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating and storage temperature\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified pressure-seal rating\u003c\/td\u003e\n\u003ctd\u003e34 bar (500 psi) nitrogen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e03 | Underwater Installation — Important Fluid Boundaries\u003c\/h3\u003e\n\u003cp\u003eThe 100630 underwater probe family is designed for applications where the probe body is submerged or exposed to fluids. However, \u003cstrong\u003ethe connector end is not sealed against liquids and must not be submerged\u003c\/strong\u003e. The protective tubing attached to the probe case protects the probe cable; it does not make the complete probe-and-connector assembly suitable for immersion.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe body:\u003c\/strong\u003e Suitable for the intended fluid-exposure conditions within the specified environmental limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable protection:\u003c\/strong\u003e Tefzel tubing protects the cable along the specified section of the assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector end:\u003c\/strong\u003e Keep the connector out of liquids. Provide a suitable mounting and routing arrangement to prevent fluid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSalt water:\u003c\/strong\u003e The 304 stainless-steel probe case is not suitable for salt-water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure sealing:\u003c\/strong\u003e The stated rating is 34 bar (500 psi) with nitrogen. Do not assume this automatically certifies every installed assembly for a different fluid, temperature, or pressure profile.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor higher-pressure service, the supplied documentation indicates that modifications may be available. Confirm the required pressure-seal test and approved configuration with the supplier before use.\u003c\/p\u003e\n\u003ch3\u003e04 | Measurement Chain and System Compatibility\u003c\/h3\u003e\n\u003cp\u003eA proximity probe is part of a measurement system, not a standalone vibration monitor. For a typical 3300 XL displacement-measurement channel, engineers must verify the complete chain:\u003c\/p\u003e\n\u003cblockquote\u003eProbe → Compatible extension cable → Compatible Proximitor sensor → Monitoring system\u003c\/blockquote\u003e\n\u003cp\u003eBefore replacing a probe, confirm the required 8 mm system configuration, the compatible extension cable and Proximitor model, the total electrical cable length, and the monitoring channel's configuration. Do not assume that all 3300 XL components are interchangeable solely because they share the same series name.\u003c\/p\u003e\n\u003cp\u003eAlso verify the physical probe target, mounting bracket, thread engagement, probe gap, and required measurement range. Incorrect mechanical geometry or an unmatched electrical chain can produce misleading readings even when the probe itself is functioning correctly.\u003c\/p\u003e\n\u003ch3\u003e05 | Suitable Equipment and Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWet-environment rotating machinery:\u003c\/strong\u003e Displacement measurement where the probe body may encounter water or other compatible fluids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and fluid-handling equipment:\u003c\/strong\u003e Monitoring compatible shaft-position or displacement measurement points where the installation geometry permits the specified probe arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial machinery protection systems:\u003c\/strong\u003e Use as the probe element in a correctly configured Bently Nevada proximity measurement channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery in enclosed or fluid-exposed locations:\u003c\/strong\u003e Applications requiring cable protection along the probe case, while keeping the connector end outside the liquid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance replacement projects:\u003c\/strong\u003e Replacement of a matching 100630 configuration when suffix, cable length, mating components, pressure conditions, and mounting dimensions have been verified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplication suitability depends on the target material, probe gap, system calibration, fluid chemistry, pressure, temperature, and installation method. The stated specifications do not establish suitability for salt water or for submerging the connector.\u003c\/p\u003e\n\u003ch3\u003e06 | Field Diagnostics: Separate Probe, Cable, and System Faults\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved condition\u003c\/th\u003e\n\u003cth\u003ePotential cause\u003c\/th\u003e\n\u003cth\u003eEngineering check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable displacement reading\u003c\/td\u003e\n\u003ctd\u003eLoose mounting, target runout, cable or connector issue, or incorrect probe gap\u003c\/td\u003e\n\u003ctd\u003eInspect mounting rigidity, target condition, cable routing, and the configured probe gap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected signal after fluid exposure\u003c\/td\u003e\n\u003ctd\u003eLiquid ingress at the connector, damaged cable protection, or compromised connection\u003c\/td\u003e\n\u003ctd\u003eInspect the connector end and cable assembly. Confirm whether any part not rated for immersion was exposed to liquid.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal remains out of expected range\u003c\/td\u003e\n\u003ctd\u003eIncorrect electrical matching, open or damaged cable, incompatible Proximitor, or incorrect channel setup\u003c\/td\u003e\n\u003ctd\u003eVerify the probe, extension cable, Proximitor, and monitor channel as one compatible system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading changes after maintenance\u003c\/td\u003e\n\u003ctd\u003eProbe position changed, mounting thread disturbed, or cable routing altered\u003c\/td\u003e\n\u003ctd\u003eRecheck mounting dimensions, gap, connection security, and system setup against the maintenance record.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal concern in a pressurized installation\u003c\/td\u003e\n\u003ctd\u003ePressure exceeds the verified configuration, unsuitable medium, or incorrect installation\u003c\/td\u003e\n\u003ctd\u003eConfirm the applicable seal rating and test requirements. Do not rely on the nitrogen rating as proof of suitability for every service condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion or surface damage\u003c\/td\u003e\n\u003ctd\u003eFluid chemistry incompatible with the 304 stainless-steel case\u003c\/td\u003e\n\u003ctd\u003eReview the fluid composition and materials compatibility before returning the probe to service.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic approach:\u003c\/strong\u003e Begin with the installation and fluid boundary, then inspect the probe cable and connector, verify the matched extension cable and Proximitor, and finally review the monitor channel configuration. A poor reading does not by itself prove that the probe has failed.\u003c\/p\u003e\n\u003ch3\u003e07 | Temperature and Hazardous-Area Considerations\u003c\/h3\u003e\n\u003cp\u003eThe specified probe operating and storage temperature range is -51°C to +177°C. Confirm that the actual installation temperature remains within this range and within the limits of the other components in the measurement chain.\u003c\/p\u003e\n\u003cp\u003eThe supplied hazardous-area information includes the following approval markings and installation conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic safety:\u003c\/strong\u003e Class I, Zone 0; AEx\/Ex ia IIC T5...T1 Ga.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision classification:\u003c\/strong\u003e Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; Class III.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation condition:\u003c\/strong\u003e Intrinsically safe zener barriers per drawing 141092 or suitable galvanic isolators, as applicable to the approved system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-incendive \/ increased protection markings:\u003c\/strong\u003e nA, ec Class I, Zone 2; AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, and D; and Class I, Zone 2 AEx\/Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the exact certification applicable to the supplied item, the temperature schedule, barrier or isolator requirements, and the installation drawing before using the probe in a hazardous location. Do not treat the probe marking alone as approval of the entire measurement loop.\u003c\/p\u003e\n\u003ch3\u003e08 | Global PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eFor the 100630-82-89-50-01, the critical selection detail is the combination of fluid exposure, connector location, and the exact suffix configuration. The underwater design applies to the probe body and protected cable section; it does not permit immersion of the connector end. This distinction should be included in the installation review, especially where water can rise, splash, or collect around the cable termination.\u003c\/p\u003e\n\u003cp\u003eBefore ordering a replacement, compare the complete part number and measure the installed probe's unthreaded length, overall case length, and cable routing requirement. Confirm that the 5 m cable configuration matches the intended 3300 XL measurement chain. In pressure service, verify the actual medium and the required seal test rather than relying on the nominal nitrogen rating alone.\u003c\/p\u003e\n\u003cp\u003eFor troubleshooting, document the monitor channel's normal reading, probe gap, recent maintenance, and any fluid exposure before replacing parts. These records help distinguish a mounting or cable problem from a failed probe or mismatched Proximitor system.\u003c\/p\u003e\n\u003ch3\u003e09 | Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the entire 100630-82-89-50-01 assembly be submerged?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The probe body is designed for specified fluid-exposure applications, but the connector end is not sealed against liquids and must not be submerged. The installation must keep the connector dry and protect the cable termination from fluid ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is this probe suitable for seawater or salt-water service?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The supplied specification states that the probe case uses 304 stainless steel and is not suitable for salt-water applications. Confirm material compatibility with the actual process fluid before selecting a probe for other corrosive environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should I verify if the original probe uses a different cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete measurement-chain configuration, including the extension cable and Proximitor sensor. Cable lengths are part of the electrical system design; do not substitute a different length based only on physical reach. Confirm the required system length and compatibility in the applicable Bently Nevada documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the 34 bar pressure rating guarantee use in any liquid at that pressure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The supplied rating specifies sealing at 34 bar (500 psi) with nitrogen. Fluid compatibility, temperature, installation details, and the required seal test must also be considered. Contact the supplier or manufacturer if the application requires a different medium or a higher-pressure test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What details should I provide when requesting a replacement quote?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full part number, required quantity, probe mounting dimensions, cable length, mating extension cable and Proximitor details, fluid exposure, operating temperature, pressure conditions, and hazardous-area requirements. These details help confirm both the mechanical configuration and measurement-system compatibility.\u003c\/p\u003e\n\u003ch3\u003e10 | Ordering, Warranty and Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 100630-82-89-50-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 3300 XL 8 mm underwater proximity probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e 24–48 hours after order and payment confirmation, subject to stock availability and order processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a quote:\u003c\/strong\u003e Send the full model number \u003cstrong\u003e100630-82-89-50-01\u003c\/strong\u003e, required quantity, destination, and application conditions to help verify the configuration before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/100630.png?v=1788145994\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67644225323190,"sku":"100630-82-89-50-01","price":132.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/100630_b293a243-5722-4e68-bc37-9758b98dbed1.jpg?v=1792047056","url":"https:\/\/www.plcsparehub.com\/products\/100630-82-89-50-01-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}