{"product_id":"02173006-99-bently-nevada-18-awg-2-conductor-shielded-cable","title":"02173006-99 Bently Nevada 18 AWG 2-Conductor Shielded Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Executive Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e02173006-99\u003c\/strong\u003e\u003c\/span\u003e is an industrial-grade, 2-conductor 18 AWG twisted and shielded bulk interconnect cable manufactured by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e. Designed specifically for critical machinery protection networks, this raw signal cable links field-mounted vibration sensors, accelerometers, velocity pickups, and Proximitor sensor modules back to centralized rack monitoring systems.\u003c\/p\u003e\n\u003cp\u003eConstructed with high-purity stranded copper drivers, a twisted-pair geometry to mitigate electromagnetic interference (EMI), and a 100% coverage overall shield, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e02173006-99\u003c\/strong\u003e\u003c\/span\u003e cable ensures clean, low-attenuation signal transmission over extended distances. Supplied in bulk spool lengths without pre-terminated connectors or lugs, it offers full flexibility for custom field wiring and conduit pulls.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Engineering Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn turbomachinery and rotating equipment monitoring systems, high-frequency low-voltage signals are susceptible to stray industrial ground loops and electrical noise generated by nearby variable frequency drives. The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 02173006-99\u003c\/strong\u003e\u003c\/span\u003e bulk cable is engineered with precise conductor twisting to maximize common-mode noise rejection across long terminal runs.\u003c\/p\u003e\n\n\u003cp\u003eDuring a turbine monitoring system overhaul at a petrochemical plant, field engineers experienced intermitten dynamic signal noise on several proximity channels. Replacing deteriorating third-party field wiring with dedicated \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e02173006-99\u003c\/strong\u003e\u003c\/span\u003e shielded cable eliminated high-frequency cross-talk and restored stable vibration spectral baseline readouts across all monitoring channels.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eCatalog Segment\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eConfiguration Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003e02173006\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eBase Product Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 2-Conductor 18 AWG Shielded Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003e-99\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSpool Length Option\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e99 Feet Continuous Bulk Length (Unterminated Ends)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eWire Gauge \u0026amp; Strand Structure\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e18 AWG Twisted Pair (2-Conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eNoise Isolation Layer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOverall Foil\/Braid Shield with Continuous Drain Wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTerminations\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eConnector Assembly Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRaw Cable Ends (No Connectors or Lugs Attached)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameters \u0026amp; Structural Specs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand \/ Manufacturer:\u003c\/strong\u003e Bently Nevada \/ Baker Hughes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart \/ Catalog Number:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e02173006-99\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bulk Instrumentation \u0026amp; Sensor Interconnect Cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Gauge:\u003c\/strong\u003e 18 AWG (American Wire Gauge)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Count:\u003c\/strong\u003e 2 Conductors (Twisted Pair Configuration)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding Type:\u003c\/strong\u003e Foil Shield with Stranded Tinned Copper Drain Wire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 99 Feet (~30.1 Meters)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJacket Material:\u003c\/strong\u003e High-Density Industrial Grade Outer Sheath\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacitance (Conductor-to-Conductor):\u003c\/strong\u003e Optimized Low-Capacitance Core\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 300V Standard Instrumentation Level\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Configuration:\u003c\/strong\u003e Bare Cut Ends for Custom Field Crimp\/Solder Connections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios \u0026amp; System Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePoint-to-point field wiring connecting Bently Nevada Proximitor sensor housings to 3500 Series or 3300 Series rack monitors.\u003c\/li\u003e\n  \u003cli\u003eInterfacing piezoceramic accelerometers and seismic velocity transducers to junction box terminal strip blocks.\u003c\/li\u003e\n  \u003cli\u003eRouting vibration signals through industrial rigid or flexible conduit systems in hazardous processing zones.\u003c\/li\u003e\n  \u003cli\u003eDiagnostic loop continuity testing and signal degradation troubleshooting using TDR (Time-Domain Reflectometry) and insulation resistance testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation, Maintenance \u0026amp; Logistics Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen installing \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e02173006-99\u003c\/strong\u003e\u003c\/span\u003e cable through plant conduit or cable trays, maintain proper minimum bend radius limits to prevent damaging the internal foil shield or straining conductors. Ensure the shield drain wire is connected to ground at one end only (typically at the monitoring rack end) to prevent ground loops that introduce signal ripple.\u003c\/p\u003e\n\u003cp\u003eStrip outer jacket ends carefully with dedicated cable stripping tools to avoid nicking the 18 AWG copper strands or inner conductor insulation layers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x 99-Foot Spool of \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 02173006-99 Bulk Cable\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Express Dispatch:\u003c\/strong\u003e Orders process and ship within 24 to 48 hours via premium express air carriers including FedEx, UPS, and DHL worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Guarantee:\u003c\/strong\u003e Supplied with a full 12-month replacement warranty covering physical manufacturing defects and conductor continuity under standard installation conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions \u0026amp; Technical Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main operational advantage of using an 18 AWG conductor gauge versus lighter 22 AWG sensor cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The larger cross-sectional area of 18 AWG conductors reduces total DC loop resistance over long runs, minimizing voltage drop and signal attenuation when running signals hundreds of feet back to the control room.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why is the drain wire shield grounding rule critical during field installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Grounding the cable shield at both ends creates a potential difference loop across the plant ground plane, introducing AC hum into sensitive 200 mV\/mil proximity signals. Always insulate the shield at the field transducer head and earth it at the rack monitor ground bus.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How do technicians test for conductor degradation or broken insulation in installed cable runs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Disconnect both ends of the cable run and perform a DC resistance test across the two conductors, followed by a 500V Megohmmeter (Megger) test between each conductor and the drain shield. Low insulation resistance points to moisture ingress or jacket abrasion inside the conduit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Does this 99-foot spool come pre-terminated with BNC or terminal lug connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: No, the -99 designation indicates raw bulk cable supplied with plain cut ends, giving installation crews complete freedom to strip, crimp, or solder custom terminal lugs or BNC connectors on site.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What critical factors should guide cable selection for long-distance vibration transducer loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Evaluate overall length requirements, ambient environmental temperatures, exposure to oil or chemical splashes, and the total cable capacitance per foot, as excessive capacitance can attenuate high-frequency peak-to-peak vibration spikes.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45277544808630,"sku":"02173006-99","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-035-00-001_56e6e7ef-15e8-48f9-8d05-319af29a4669.jpg?v=1784792376","url":"https:\/\/www.plcsparehub.com\/products\/02173006-99-bently-nevada-18-awg-2-conductor-shielded-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}