{"product_id":"tc-oav061-honeywell-analog-output-module-6-channel-isolated","title":"TC-OAV061 Honeywell Analog Output Module 6-Channel Isolated","description":"\u003ch3\u003e\u003cb\u003eHoneywell TC-OAV061 | 6-Channel Isolated Analog Voltage Output Module\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-OAV061\u003c\/strong\u003e is a six-channel analog output module designed to provide isolated voltage signals for compatible industrial control systems. Each channel supports an output range of ±10.50 VDC, with 14-bit resolution across a 21 V span. The module is specified for loads of 1 kΩ or higher and has an output impedance below 3 Ω.\u003c\/p\u003e\n\n\u003cp\u003eFor control engineers, the key design characteristics are channel-to-channel and user-to-system isolation, fast output settling, electronic short-circuit current limiting, and a 25 ms update rate for all channels. The module connects through the specified TC-TBNH 20-position terminal block. Confirm the host controller, I\/O base, terminal-block arrangement, and configuration requirements before ordering.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eAt a Glance: Signal Performance\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eTC-OAV061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e±10.50 VDC into loads of 1 kΩ or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bits across 21 V; approximately 1.4 mV per step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003eLess than 3 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy at 25°C\u003c\/td\u003e\n\u003ctd\u003eBetter than 0.1% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling Time\u003c\/td\u003e\n\u003ctd\u003eLess than 2 ms to 95% of final value with resistive loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eTC-TBNH, 20-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 months, subject to confirmed sales terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eElectrical Characteristics That Matter in the Field\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated signal paths:\u003c\/strong\u003e Channel-to-channel and user-to-system isolation are each 100% tested at 2546 VDC for 1 second, according to the supplied specifications. This test rating should not be interpreted as a continuous operating voltage rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution and accuracy:\u003c\/strong\u003e The stated 14-bit resolution provides approximately 1.4 mV per step across the 21 V output span. Calibrated accuracy is better than 0.1% of range at 25°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow output impedance:\u003c\/strong\u003e An impedance below 3 Ω supports voltage signal delivery to compatible loads. The specified output range applies to loads of 1 kΩ or higher.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response:\u003c\/strong\u003e Settling to 95% of the final value takes less than 2 ms with resistive loads, while the module update rate for all channels is 25 ms. These are different performance measures and should not be treated as interchangeable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput protection:\u003c\/strong\u003e The module provides continuous electronic current limiting for output short circuits. The stated overvoltage protection is 24 VAC\/VDC continuous at room temperature; observe the manufacturer's wiring and fault-handling requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eTypical Control Applications\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eWhen installed in a compatible Honeywell control platform, the TC-OAV061 can supply analog voltage references to equipment that accepts the specified bipolar voltage signal. Actual use depends on the host system configuration and the receiving device's input requirements.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication Area\u003c\/th\u003e\n\u003cth\u003eExample Signal Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess control\u003c\/td\u003e\n\u003ctd\u003eVoltage reference signals for compatible actuators or control devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial equipment regulation\u003c\/td\u003e\n\u003ctd\u003eCommand signals to equipment with a supported ±10 V input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl-system retrofits\u003c\/td\u003e\n\u003ctd\u003eReplacement of a specified analog output module in an existing compatible installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-channel control\u003c\/td\u003e\n\u003ctd\u003eIndependent voltage outputs for several receiving devices, subject to system configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest and commissioning systems\u003c\/td\u003e\n\u003ctd\u003eGeneration of configured analog reference signals during approved control-system testing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatibility reminder:\u003c\/strong\u003e The supplied specifications do not identify the exact host controller or I\/O family. Verify the Honeywell system model, supported module list, firmware or configuration requirements, and terminal-block compatibility before selecting this part.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Commissioning: Engineer's Checklist\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the hardware identity.\u003c\/strong\u003e Confirm the TC-OAV061 label and verify that the host system documentation specifies this module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the terminal block.\u003c\/strong\u003e Confirm the TC-TBNH 20-position terminal block and check the terminal assignments against the correct wiring diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview the receiving load.\u003c\/strong\u003e Ensure each connected device accepts the intended voltage range and presents a load of at least 1 kΩ, as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect isolation and grounding.\u003c\/strong\u003e Follow the approved system design for signal returns, shielding, and grounding. Do not bridge isolated channels through external wiring unless the design permits it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck output scaling.\u003c\/strong\u003e Verify the engineering-unit range, polarity, zero point, and full-scale command in the controller configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the signal safely.\u003c\/strong\u003e Where permitted by the site procedure, compare the configured command with a calibrated meter reading at the designated test point before connecting or enabling the final load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm system behavior.\u003c\/strong\u003e Check the controller's module status, channel values, alarms, and receiving-device response before returning the loop to normal service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cb\u003eDiagnostic Guide: From Symptom to Likely Cause\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Problem\u003c\/th\u003e\n\u003cth\u003eChecks and Diagnostic Actions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo voltage at one channel\u003c\/td\u003e\n\u003ctd\u003eVerify the configured output value, terminal assignment, wiring continuity, load connection, and controller channel status. Measure at the designated test point using an appropriate meter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage is consistently too high or too low\u003c\/td\u003e\n\u003ctd\u003eCheck engineering-unit scaling, output polarity, the expected command range, meter setup, and the receiving device's input impedance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput changes slowly or appears unstable\u003c\/td\u003e\n\u003ctd\u003eCompare the observed behavior with the 25 ms module update rate and the receiving device's response. Inspect wiring, grounding, electrical noise, and load characteristics.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral channels show abnormal readings\u003c\/td\u003e\n\u003ctd\u003eReview common configuration or supply conditions, terminal-block seating, controller diagnostics, and whether the channels share an external wiring or grounding issue.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput fails under a connected load\u003c\/td\u003e\n\u003ctd\u003eConfirm the load is at least 1 kΩ and that the wiring has no short circuit. Check the receiving device's input specification and the module's protection status where available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-related drift\u003c\/td\u003e\n\u003ctd\u003eCompare operating conditions with the specified typical offset drift of 60 µV\/°C and gain drift of 50 ppm\/°C. Verify measurement accuracy and calibration requirements before condemning the module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant diagnostic limit:\u003c\/strong\u003e The supplied specification states that open-circuit detection is not provided. Therefore, do not assume the module will automatically identify a disconnected load. Use controller-side monitoring, external feedback, or a suitable measurement procedure if the application requires open-circuit detection.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eFor the TC-OAV061, the most important selection checks are the bipolar voltage range, minimum load impedance, isolation requirements, and terminal-block match. A six-channel output count alone is not enough to confirm suitability.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen replacing an existing unit:\u003c\/strong\u003e Match the full part number and verify the host system's supported hardware list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen diagnosing poor control performance:\u003c\/strong\u003e Compare the commanded voltage, measured voltage, and receiving-device response. This helps separate scaling errors from wiring or module faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen using isolated channels:\u003c\/strong\u003e Check the complete field wiring. External commons or grounded instruments can unintentionally create connections between circuits that are intended to remain isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen planning procurement:\u003c\/strong\u003e Confirm the TC-TBNH terminal block, unit condition, warranty, availability, and delivery timing before scheduling a shutdown or replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eSupply, Warranty \u0026amp; Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Honeywell TC-OAV061 Analog Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e 6-channel isolated voltage output, ±10.50 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original factory packing, subject to stock confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to confirmed sales terms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, and DHL options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e Contact Global PLC Spare HUB for current stock, quotation, and estimated delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the TC-OAV061 to drive a 500 Ω input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied output specification is for loads of 1 kΩ or higher. A 500 Ω load falls outside that stated condition, so do not assume correct operation. Check the official hardware documentation or use an output device rated for the receiving load.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Is the 14-bit resolution the same as the module's total accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Resolution describes the smallest nominal output step, approximately 1.4 mV across the 21 V span. Accuracy describes how closely the actual output matches the commanded value; the supplied calibrated accuracy is better than 0.1% of range at 25°C. System-level error can also include wiring, measurement, and receiving-device errors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What should I check if the output is correct at the terminal but the actuator does not respond properly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Check the actuator's accepted input range, signal polarity, input impedance, common\/reference wiring, scaling, and any enable or interlock conditions. If the voltage at the module terminal is correct, investigate the signal path and receiving device before replacing the output module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Does galvanic isolation mean the six channels can be wired together freely?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Isolation is an electrical design feature, not permission to connect channel returns or external grounds arbitrarily. Follow the module's wiring instructions and the control-system grounding design to preserve the intended isolation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What details should I send when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Provide the full model number TC-OAV061, a photo of the installed module label, the host Honeywell control-system model, the terminal-block part number, required quantity, and delivery destination. If replacing a failed unit, include the symptom and measured output values to help clarify whether any associated hardware should also be checked.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67819906072758,"sku":"TC-OAV061","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TC-OAV061.jpg?v=1793069165","url":"https:\/\/www.plcsparehub.com\/es\/products\/tc-oav061-honeywell-analog-output-module-6-channel-isolated","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}