{"product_id":"honeywell-xnx-amav-rnnnn-universal-transmitter-atex-gas-detector","title":"Honeywell XNX-AMAV-RNNNN Universal Transmitter | ATEX Gas Detector","description":"\u003cdiv\u003e\n\u003ch3\u003eOverview \u0026amp; Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eHoneywell\u003c\/b\u003e \u003cb\u003e\u003cb\u003eXNX Universal Transmitter\u003c\/b\u003e\u003c\/b\u003e model \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e represents an advanced gas detection platform engineered for harsh industrial environments. Operating as a universal gas transmitter, this unit integrates seamlessly with diverse sensor technologies while delivering robust analog and digital communication. Built into a durable painted aluminum housing with multiple M25 cable entries, the device provides exceptional field resilience and long-term operational reliability for mission-critical safety systems.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: In high-stakes petrochemical processing plants where combustible or toxic gases present continuous hazards, deploying the \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e ensures rapid response times and failsafe relay integration. Field engineers appreciate the standardized modular design, which drastically minimizes spare parts inventory requirements across multi-zone facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%; border-color: #d1d5db;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f3f4f6;\"\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter Category\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eTechnical Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand \u0026amp; Model\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eHoneywell\u003c\/b\u003e \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e (\u003cb\u003e\u003cb\u003eXNX Series\u003c\/b\u003e\u003c\/b\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Gas Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMeasuring Range \u0026amp; Compatibility\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigured for \u003cb\u003eSensepoint High Temperature Sensor\u003c\/b\u003e (milli-Volt sensor interface supporting MPD, Sensepoint, and Model 705 HT\/PPM sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutput \u0026amp; Diagnostics\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eHART over 4-20mA output, 3 built-in fault\/alarm relays (Fault, Alarm 1, Alarm 2) with continuous self-test diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEnvironmental \u0026amp; Enclosure Rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePainted Aluminium housing, 5 x M25 entries, designed for hazardous industrial atmospheres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResponse Time \u0026amp; Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eFast transient detection with linear output tracking across standard operational ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Mounting Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e securely onto vertical walls or structural pipe brackets using certified mounting hardware.\u003c\/li\u003e\n\u003cli\u003eEnsure correct orientation of the 5 x M25 cable entries to prevent moisture ingress during washdown cycles.\u003c\/li\u003e\n\u003cli\u003eTerminate incoming power and 4-20mA signal loops according to local electrical codes inside the explosion-proof terminal chamber.\u003c\/li\u003e\n\u003cli\u003eVerify earth grounding integrity to maintain electromagnetic interference immunity in heavy electrical switchgear areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning \u0026amp; Maintenance Convenience\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower on the unit and utilize the local interface screen for initial sensor recognition and zero calibration.\u003c\/li\u003e\n\u003cli\u003ePerform routine functional bump tests using certified test gas cylinders directly applied via calibration adapters.\u003c\/li\u003e\n\u003cli\u003eInspect terminal screws and housing seals annually to ensure long-term environmental sealing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirectly interfaces with legacy and modern milli-Volt combustible gas sensors including MPD and Sensepoint lines.\u003c\/li\u003e\n\u003cli\u003eIntegrates smoothly into Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC) via 4-20mA analog loops.\u003c\/li\u003e\n\u003cli\u003eSupports digital asset management tools through HART protocol overlays without rewiring existing infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eATEX\u003c\/b\u003e \/ \u003cb\u003eIECEx\u003c\/b\u003e certified for deployment in explosive gas atmospheres (Zone 1 and Zone 2).\u003c\/li\u003e\n\u003cli\u003eComplies with industrial safety standards for electrical apparatus operating in hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging, Warranty \u0026amp; Shipping Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging List\u003c\/b\u003e: \u003cb\u003eHoneywell\u003c\/b\u003e \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e transmitter unit, protective dust caps, multi-language quick start guide, and factory calibration certificate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty\u003c\/b\u003e: Comprehensive 12-month quality warranty covering manufacturing defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping Logistics\u003c\/b\u003e: Fast 24-48 hour dispatch via trusted global carriers including \u003cb\u003eFedex\u003c\/b\u003e, \u003cb\u003eUPS\u003c\/b\u003e, and \u003cb\u003eDHL\u003c\/b\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas upstream exploration platforms and downstream refining complexes.\u003c\/li\u003e\n\u003cli\u003eChemical manufacturing and solvent storage facilities requiring continuous vapor monitoring.\u003c\/li\u003e\n\u003cli\u003ePower generation plants and heavy industrial manufacturing shop floors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Can the \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e operate without an attached local HART configuration module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit suffix indicates no optional local HART display module is installed, but standard HART communication over the 4-20mA loop remains fully functional.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What field calibration steps are required when replacing the Sensepoint High Temperature Sensor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: After physical sensor replacement, allow the unit a 30-minute warm-up stabilization period, execute a zero calibration in clean air, and perform a span calibration using standard test gas.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How do the internal relays function during a primary alarm event?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 3 onboard mechanical relays provide dedicated contact closures for Fault, Alarm 1, and Alarm 2, allowing direct interlock triggering of external horns, strobes, or emergency shutdown valves.\u003c\/p\u003e\n\u003ch3\u003eBuying Guide\u003c\/h3\u003e\n\u003cp\u003eWhen selecting gas detection infrastructure for hazardous industrial settings, verify area classification requirements against ATEX\/IECEx ratings. Ensure that sensor personality cards match your specific detection targets—such as the milli-Volt sensor interface on the \u003cb\u003e\u003cb\u003eXNX-AMAV-RNNNN\u003c\/b\u003e\u003c\/b\u003e—to guarantee optimal signal fidelity and loop stability. Purchasing through authorized channels ensures full 12-month warranty backing and rapid 24-48 hour logistics support.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX.png?v=1787714324\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45384027078838,"sku":"XNX-AMAV-RNNNN","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NNNNN_2.jpg?v=1787714949","url":"https:\/\/www.plcsparehub.com\/es\/products\/honeywell-xnx-amav-rnnnn-universal-transmitter-atex-gas-detector","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}