{"product_id":"honeywell-2108b2001h-searchpoint-optima-plus-hart-gas-detector","title":"Honeywell 2108B2001H Searchpoint Optima Plus HART Gas Detector","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677a8;\"\u003eHoneywell 2108B2001H\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003eSearchpoint Optima Plus\u003c\/strong\u003e point-infrared hydrocarbon gas detector. It monitors flammable gas concentrations in potentially explosive industrial environments.\u003c\/p\u003e\n\u003cp\u003eThis HART-enabled configuration combines infrared sensing with continuous 4–20 mA signal transmission. It supports hydrocarbon detection across a standard \u003cstrong\u003e0–100% LEL\u003c\/strong\u003e measuring range.\u003c\/p\u003e\n\u003cp\u003eThe detector uses a \u003cstrong\u003e316 stainless steel\u003c\/strong\u003e enclosure for demanding industrial installations. Its IP66\/IP67 protection supports outdoor and harsh environmental applications. The device also provides advanced diagnostics through a certified handheld interrogator or HART communication.\u003c\/p\u003e\n\u003cp\u003eWith ATEX, IECEx, UL, and CSA approval options, the \u003cstrong\u003e2108B2001H\u003c\/strong\u003e supports gas detection requirements in hazardous areas. Its \u003cstrong\u003eSIL 2\u003c\/strong\u003e capability also supports functional safety system designs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2108B2001H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSearchpoint Optima Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePoint-Infrared Flammable Gas Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Technology\u003c\/td\u003e\n\u003ctd\u003eInfrared Absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Gas\u003c\/td\u003e\n\u003ctd\u003eHydrocarbon gases and vapors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Measuring Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0–100% LEL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Calibration\u003c\/td\u003e\n\u003ctd\u003eMultiple hydrocarbon gas and vapor calibrations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Applications\u003c\/td\u003e\n\u003ctd\u003eAlternative measuring ranges and solvent calibrations available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, autosensing sink or source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eOptional HART over 4–20 mA, HART Version 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Communication\u003c\/td\u003e\n\u003ctd\u003eOptional multidrop Modbus RS485 via DX100(M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC, 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003e316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP66 \/ IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eSIL 2, IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe infrared sensing system provides fast response and stable hydrocarbon measurement. The following specifications describe the detector's measurement performance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHydrocarbon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEthylene\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Accuracy\u003c\/td\u003e\n\u003ctd\u003eLess than ±1% FSD\u003c\/td\u003e\n\u003ctd\u003eLess than ±2% FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 50% FSD\u003c\/td\u003e\n\u003ctd\u003eLess than ±2% FSD\u003c\/td\u003e\n\u003ctd\u003eLess than ±3% FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability at 50% FSD\u003c\/td\u003e\n\u003ctd\u003eLess than ±2% FSD\u003c\/td\u003e\n\u003ctd\u003eLess than ±2% FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eLess than 5% FSD\u003c\/td\u003e\n\u003ctd\u003eLess than 5% FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time T50\u003c\/td\u003e\n\u003ctd\u003eLess than 3 seconds\u003c\/td\u003e\n\u003ctd\u003eGas-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time T90\u003c\/td\u003e\n\u003ctd\u003eLess than 4 seconds\u003c\/td\u003e\n\u003ctd\u003eGas-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Reference:\u003c\/strong\u003e The specified response times apply to methane. FSD means full-scale deflection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Signal and Output Status\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2108B2001H\u003c\/strong\u003e provides a 4–20 mA output for integration with industrial control systems. Its output supports automatic sink or source detection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInhibit\u003c\/td\u003e\n\u003ctd\u003e1–3 mA, default 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning\u003c\/td\u003e\n\u003ctd\u003e0–6 mA, default 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault\u003c\/td\u003e\n\u003ctd\u003e0 mA; adjustable to 1 mA on HART units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Measurement\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverrange\u003c\/td\u003e\n\u003ctd\u003e20–21.5 mA, default 21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eIntegration Note:\u003c\/strong\u003e Configure the receiving controller to recognize inhibit, warning, fault, and overrange states. Do not interpret every current below 4 mA as a normal gas reading.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLong-Term Stability and Environmental Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe detector maintains measurement stability across demanding operating conditions. Its published stability specifications follow EN 60079-29-1.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMethane, 100% LEL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEthylene, 100% LEL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Long-Term Stability\u003c\/td\u003e\n\u003ctd\u003e≤ ±2% FSD\u003c\/td\u003e\n\u003ctd\u003e≤ ±4% FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability at 50% FSD\u003c\/td\u003e\n\u003ctd\u003e≤ ±4% FSD\u003c\/td\u003e\n\u003ctd\u003e≤ ±5% FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBaseline drift across -40°C to +65°C: ≤ ±2% FSD.\u003c\/li\u003e\n\u003cli\u003eMethane drift at 50% FSD: ≤ ±0.131% FSD per °C.\u003c\/li\u003e\n\u003cli\u003eEthylene drift at 50% FSD: ≤ ±0.078% FSD per °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Influence:\u003c\/strong\u003e Approximately 0.1% of reading per mbar.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e The 316 stainless steel housing and IP66\/IP67 rating support outdoor industrial applications. The specified operating temperature extends from -40°C to +65°C.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\u003c\/td\u003e\n\u003ctd\u003eBAS99ATEX2259X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Equipment Group\u003c\/td\u003e\n\u003ctd\u003eII 2 GD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Gas Protection\u003c\/td\u003e\n\u003ctd\u003eEx d IIC Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Dust Protection\u003c\/td\u003e\n\u003ctd\u003eEx tb IIIC Db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Temperature Rating\u003c\/td\u003e\n\u003ctd\u003eT96°C (-40°C to +65°C); T86°C (-40°C to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx\u003c\/td\u003e\n\u003ctd\u003eEx d IIC tb IIIC, IP66\/IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx Temperature Rating\u003c\/td\u003e\n\u003ctd\u003eT86°C or T96°C, depending on ambient temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL \/ CSA\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 1, Groups B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance Approval\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 152; FM ANSI\/ISA-12.13.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Performance Standard\u003c\/td\u003e\n\u003ctd\u003eEN 60079-29-1, BVS 03 ATEX G 016 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61508, SIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50270:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50271:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Verify the applicable certificate, temperature class, and ambient operating limits for the exact installation location. Certification conditions may vary by approval and configuration.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68138893967542,"sku":"2108B2001H","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/2108B2101N_d5c0006a-8321-4863-a211-5e3b0fdc625c.jpg?v=1795492992","url":"https:\/\/www.plcsparehub.com\/es\/products\/honeywell-2108b2001h-searchpoint-optima-plus-hart-gas-detector","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}