{"product_id":"evs9328-es-global-drive-9300-by-lenze-original-servo-drive","title":"EVS9328-ES Global Drive 9300 by Lenze Original Servo Drive","description":"\u003ch3\u003e\u003cb\u003eLenze EVS9328-ES Global Drive 9300 Servo Inverter\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLenze EVS9328-ES\u003c\/strong\u003e is a 22 kW servo inverter from the \u003cstrong\u003eGlobal Drive 9300 series\u003c\/strong\u003e. It is designed for controlled operation of three-phase asynchronous motors in industrial motion and automation systems.\u003c\/p\u003e\n\u003cp\u003eThis drive uses vector control and supports resolver, incremental TTL encoder, and SinCos encoder feedback through its dedicated interfaces. It integrates analog and digital I\/O, CAN system bus communication, an AIF automation interface, and expansion options for additional fieldbus protocols.\u003c\/p\u003e\n\u003cp\u003eThe EVS9328-ES provides rated output current of 47.0 A at 8 kHz and 30.6 A at 16 kHz. Its maximum output current is 150% of rated current, subject to the specified operating conditions and switching frequency.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Drive Identification \u0026amp; Performance Profile\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIdentification Item\u003c\/th\u003e\n\u003cth\u003eTechnical Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEVS9328-ES\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eGlobal Drive 9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e22.0 kW, 4-pole asynchronous motor, servo rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e32.6 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Architecture\u003c\/td\u003e\n\u003ctd\u003eVector control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003eThree-phase, 0 to Vmains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 12.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct identification:\u003c\/strong\u003e EVS9328-ES is the specified Lenze order code for the 22 kW power class. Confirm the complete nameplate code when replacing an existing drive.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | Output Ratings: Switching Frequency Matters\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe available output current depends on the selected switching frequency. Engineers should use the corresponding current rating when sizing the motor and evaluating drive loading.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Parameter\u003c\/th\u003e\n\u003cth\u003e8 kHz\u003c\/th\u003e\n\u003cth\u003e16 kHz\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e47.0 A\u003c\/td\u003e\n\u003ctd\u003e30.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e70.5 A\u003c\/td\u003e\n\u003ctd\u003e45.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Ratio\u003c\/td\u003e\n\u003ctd\u003e150% × In\u003c\/td\u003e\n\u003ctd\u003e150% × In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional electrical ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated motor power: 22.0 kW.\u003c\/li\u003e\n\u003cli\u003eOutput apparent power: 32.6 kVA.\u003c\/li\u003e\n\u003cli\u003eMains current at 400 V: 44.0 A.\u003c\/li\u003e\n\u003cli\u003eMotor output voltage: 0 to Vmains, three-phase.\u003c\/li\u003e\n\u003cli\u003eMaximum output current: 150% of rated current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe maximum output current figures are based on the published 150% × In ratings. An overload specification of 180% for 60 seconds is not adopted because it is not confirmed in the cited official product data.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Supply Requirements and Power Loss\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e320–528 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Current at 400 V\u003c\/td\u003e\n\u003ctd\u003e44.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss at 400 V\u003c\/td\u003e\n\u003ctd\u003e640 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Derating Above 40°C\u003c\/td\u003e\n\u003ctd\u003e2.5% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Derating\u003c\/td\u003e\n\u003ctd\u003e5% per 1,000 m from 1,000 to 4,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePanel design considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize the upstream supply and protection devices according to the drive's electrical ratings and the applicable installation manual.\u003c\/li\u003e\n\u003cli\u003eAccount for approximately 640 W of drive power loss when calculating cabinet heat dissipation.\u003c\/li\u003e\n\u003cli\u003eProvide sufficient ventilation and clearance around the inverter.\u003c\/li\u003e\n\u003cli\u003eApply current derating when the ambient temperature exceeds 40°C.\u003c\/li\u003e\n\u003cli\u003eInclude altitude-related derating for installations above 1,000 m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e04 | Motor Feedback and Control Interfaces\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 9300 servo platform supports several motor feedback technologies. The selected feedback device must match the motor, encoder interface, and configured control strategy.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eConnection Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX7\u003c\/td\u003e\n\u003ctd\u003eMotor feedback\u003c\/td\u003e\n\u003ctd\u003eResolver input and KTY motor temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX8\u003c\/td\u003e\n\u003ctd\u003eEncoder feedback\u003c\/td\u003e\n\u003ctd\u003eTTL incremental encoder or Stegmann SinCos encoder; KTY temperature sensor support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eAutomation interface\u003c\/td\u003e\n\u003ctd\u003eAIF interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003eAnalog input configuration\u003c\/td\u003e\n\u003ctd\u003eJumper for analog input signal selection at X6\/1 and X6\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003eSystem communication\u003c\/td\u003e\n\u003ctd\u003eCAN system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd\u003eDigital inputs and outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O\u003c\/td\u003e\n\u003ctd\u003eAnalog inputs and outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX9\u003c\/td\u003e\n\u003ctd\u003eFrequency input\u003c\/td\u003e\n\u003ctd\u003eDigital frequency input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX10\u003c\/td\u003e\n\u003ctd\u003eFrequency output\u003c\/td\u003e\n\u003ctd\u003eDigital frequency output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX11\u003c\/td\u003e\n\u003ctd\u003eSafe standstill relay\u003c\/td\u003e\n\u003ctd\u003eK_SR relay output on V004\/V104 variants only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecified analog interface signals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAIN1: X6.1 \/ X6.2.\u003c\/li\u003e\n\u003cli\u003eAOUT1: X6.62.\u003c\/li\u003e\n\u003cli\u003eAOUT2: X6.63.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe X11 K_SR relay output is variant-dependent. Do not assume this function is available on every EVS9328-ES hardware version. Verify the complete variant designation before using it in a safety-related design.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Communication and Automation Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Global Drive 9300 platform combines built-in communication interfaces with optional plug-in expansion modules.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Interface\u003c\/th\u003e\n\u003cth\u003eSupported Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 \/ RS485\u003c\/td\u003e\n\u003ctd\u003eSerial communication through Global Drive Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN System Bus\u003c\/td\u003e\n\u003ctd\u003eIntegrated system bus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIF\u003c\/td\u003e\n\u003ctd\u003eAutomation interface and expansion connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINTERBUS-S\u003c\/td\u003e\n\u003ctd\u003eFieldbus communication through a plug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003ctd\u003eFieldbus communication through a plug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLECOM A\/B\u003c\/td\u003e\n\u003ctd\u003eSerial communication using RS232\/RS485 through the applicable interface configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCommunication capability depends on the installed expansion hardware and configuration. Confirm the required protocol module before integrating the drive into an existing PLC or DCS network.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Braking System: External Hardware Required\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe EVS9328-ES requires an external braking solution for applications that need controlled dissipation of regenerative energy. The published 9300 product information identifies the following brake components.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Component\u003c\/th\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9351 Brake Module\u003c\/td\u003e\n\u003ctd\u003eIntegrated 47 Ω brake resistor; maximum peak braking power 12 kW; 1% duty cycle per 4 seconds\u003c\/td\u003e\n\u003ctd\u003eExternal braking solution with integrated resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9352 Brake Chopper\u003c\/td\u003e\n\u003ctd\u003eMinimum external braking resistance 18 Ω\u003c\/td\u003e\n\u003ctd\u003eExternal braking solution using a separately selected resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eBrake selection checks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalculate the regenerative energy generated during deceleration.\u003c\/li\u003e\n\u003cli\u003eCheck the required braking power and duty cycle.\u003c\/li\u003e\n\u003cli\u003eVerify the resistor value against the brake chopper requirements.\u003c\/li\u003e\n\u003cli\u003eCheck thermal limits and resistor installation conditions.\u003c\/li\u003e\n\u003cli\u003eFollow the Lenze brake module and brake chopper installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not treat the 9351 and 9352 as interchangeable resistor assemblies. Their braking hardware arrangements and external resistor requirements differ.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Environmental Limits and Mechanical Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Above 40°C\u003c\/td\u003e\n\u003ctd\u003eReduce output current by 2.5% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eAverage 85% RH, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic Classification\u003c\/td\u003e\n\u003ctd\u003e3K3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e350 × 250 × 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 12.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical installation notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe dimensions are family-aggregated values for the 9327, 9328, and 9329 models.\u003c\/li\u003e\n\u003cli\u003eThe stated dimensions exclude additional depth from the terminal shield and front keypad attachment.\u003c\/li\u003e\n\u003cli\u003eIP20 protection requires installation inside a suitable electrical cabinet.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow and cabinet ventilation to manage drive heat losses.\u003c\/li\u003e\n\u003cli\u003ePrevent moisture condensation during operation and storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e08 | Compliance and Electrical Safety\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCompliance Area\u003c\/th\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Conformity\u003c\/td\u003e\n\u003ctd\u003eLow-Voltage Directive 2006\/95\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61800-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Category\u003c\/td\u003e\n\u003ctd\u003eC2 according to EN 61800-3, typical drive configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL \/ UR\u003c\/td\u003e\n\u003ctd\u003eUL\/UR safety and branch-circuit protection requirements documented in the applicable manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e5,000 \/ 50,000 A RMS symmetrical, 480 V maximum, depending on the specified fuse arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor UL\/UR installations, use the specified J, T, or R class fuses and follow the applicable branch-circuit protection instructions. Confirm the required short-circuit current rating and protection arrangement for the actual installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Commissioning and Drive Replacement Checklist\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the drive rating:\u003c\/strong\u003e Match the EVS9328-ES power class and motor current requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the motor feedback:\u003c\/strong\u003e Identify whether the motor uses a resolver, TTL incremental encoder, or SinCos encoder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview parameter compatibility:\u003c\/strong\u003e Back up existing drive parameters and record motor data before replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm communication hardware:\u003c\/strong\u003e Check CAN, AIF, and any installed fieldbus expansion modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect braking equipment:\u003c\/strong\u003e Verify whether a 9351 brake module or 9352 brake chopper is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculate cabinet cooling:\u003c\/strong\u003e Include the specified drive power loss and the actual operating environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck safety-related functions:\u003c\/strong\u003e Confirm the hardware variant and applicable safety documentation before using any safe standstill-related interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform controlled startup:\u003c\/strong\u003e Verify rotation direction, feedback operation, acceleration, deceleration, and current loading.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAlways isolate the power supply and follow the approved electrical safety procedure before installation or maintenance. Use the applicable Lenze manual for parameterization, wiring, and commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Product Lifecycle and Replacement Planning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Lenze Global Drive 9300 servo inverter belongs to a previous-generation product range. Lenze documents the i950 servo inverter as a migration path for 9300 applications.\u003c\/p\u003e\n\u003cp\u003eThe documented migration approach includes compatibility-related functions and engineering resources such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ei950 compatibility switch for supported 9300 behavior.\u003c\/li\u003e\n\u003cli\u003eApplicable i950 PROFIBUS communication module.\u003c\/li\u003e\n\u003cli\u003eL_ICIP library for supported migration and integration tasks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA migration should not be treated as a direct hardware substitution. Engineers must review motor feedback, control behavior, fieldbus configuration, parameter mapping, safety functions, braking hardware, and cabinet wiring before selecting a replacement platform.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e11 | Supply, Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCommercial Information\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEVS9328-ES\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eGlobal Drive 9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e22 kW Servo Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew \u0026amp; Original in Factory Packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eFactory Warranty: 12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eContact Global PLC Spare HUB for EVS9328-ES pricing, availability, and delivery information. For replacement projects, provide the motor nameplate, feedback type, communication requirements, and existing brake configuration to support a more accurate compatibility review.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e12 | Engineering FAQs\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I replace an EVS9328-ES with another 22 kW inverter based only on motor power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Motor power alone is not sufficient for drive selection. Compare rated and peak output current, switching frequency, motor feedback, supply voltage, control mode, communication interfaces, and braking requirements. A replacement must also support the machine's acceleration, deceleration, and dynamic load profile.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why does the available output current decrease when the switching frequency changes from 8 kHz to 16 kHz?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigher switching frequency increases switching-related losses in the power stage. The drive therefore has a lower published continuous output current at 16 kHz. When configuring the application, use the current rating for the selected switching frequency rather than assuming the 8 kHz rating remains available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What information should I collect before transferring parameters to a replacement drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the motor nameplate data, feedback device type, encoder resolution where applicable, control mode, speed and torque limits, acceleration and deceleration ramps, I\/O assignments, and fieldbus settings. Also document brake control and machine interlocks. Parameter transfer should be followed by a controlled functional test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can I determine whether the existing braking hardware is suitable for a machine with frequent stopping cycles?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEstimate the regenerative energy per stop, stopping frequency, motor inertia, and required deceleration time. Compare the calculated braking duty with the 9351 module's specified peak power and duty cycle, or the 9352 chopper's resistor requirements. Frequent stopping may require a different braking design from an occasional emergency or normal deceleration cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should I investigate if a drive operates normally when cold but trips after the cabinet warms up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck cabinet temperature, ventilation, fan operation, surrounding heat sources, and actual motor current. Above 40°C, the specified output current must be derated by 2.5% per °C. Also inspect electrical connections and the drive's fault history. Do not increase current limits to compensate for inadequate cooling.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":68129228619958,"sku":"EVS9328-ES","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/EVS9328-ES.jpg?v=1795489414","url":"https:\/\/www.plcsparehub.com\/es\/products\/evs9328-es-global-drive-9300-by-lenze-original-servo-drive","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}