{"product_id":"bently-nevada-330903-01-07-10-12-05-3300-nsv-probe","title":"Bently Nevada 330903-01-07-10-12-05 3300 NSv Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a73e8;\"\u003eBently Nevada 330903-01-07-10-12-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e for non-contact shaft displacement and vibration measurements. It operates within Bently Nevada's 3300 NSv machinery protection system.\u003c\/p\u003e\n\u003cp\u003eThis probe uses an \u003cstrong\u003eM8 x 1 threaded mounting design\u003c\/strong\u003e without external armor. Its 1.0-meter integral cable features a miniature coaxial ClickLoc connector and FluidLoc cable construction.\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv design provides improved chemical resistance compared with the previous 3300 RAM probe. This characteristic supports demanding process compressor environments. Its side-view performance also improves probe positioning flexibility compared with the 3000-series 190 probe.\u003c\/p\u003e\n\u003cp\u003eThe probe measures shaft movement through eddy-current sensing. It provides dynamic displacement signals for machinery condition monitoring. Typical applications include compressors, pumps, turbines, and other rotating equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330903-01-07-10-12-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy-current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Thread\u003c\/td\u003e\n\u003ctd\u003eM8 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Configuration\u003c\/td\u003e\n\u003ctd\u003eWithout armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Probe Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Impedance\u003c\/td\u003e\n\u003ctd\u003e75 Ω coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Insulation\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene propylene (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor Tolerance\u003c\/td\u003e\n\u003ctd\u003e+12.5% \/ -20%, including interchangeability error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Deviation\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.06 mm (±2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz, +0 \/ -3 dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e4.2 ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Diameter\u003c\/td\u003e\n\u003ctd\u003e8.9 mm (0.35 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Target Diameter\u003c\/td\u003e\n\u003ctd\u003e13 mm (0.5 inches) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Engagement\u003c\/td\u003e\n\u003ctd\u003e12 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals, option 05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew, factory original packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Measurement Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe probe provides a \u003cstrong\u003e1.5 mm (60 mil) linear measurement range\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIts linear operating region extends approximately from 0.25 to 1.75 mm.\u003c\/li\u003e\n\u003cli\u003eThe corresponding output range is approximately -1 to -13 VDC.\u003c\/li\u003e\n\u003cli\u003eThe recommended initial gap is 1.0 mm (40 mils).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Sensitivity and Linearity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncremental scale factor: \u003cstrong\u003e7.87 V\/mm (200 mV\/mil)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eScale factor tolerance: +12.5% \/ -20%.\u003c\/li\u003e\n\u003cli\u003eLinearity deviation from the best-fit straight line remains below ±0.06 mm.\u003c\/li\u003e\n\u003cli\u003eThese characteristics support shaft displacement and vibration measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Frequency Response\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTypical frequency response covers \u003cstrong\u003e0 to 10 kHz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAmplitude response remains within +0 \/ -3 dB under specified conditions.\u003c\/li\u003e\n\u003cli\u003eThe specification supports field wiring lengths up to 305 meters.\u003c\/li\u003e\n\u003cli\u003eLonger field wiring can increase high-frequency signal attenuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Electrical and Noise Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe probe uses a 75 Ω coaxial signal cable.\u003c\/li\u003e\n\u003cli\u003eFEP insulation supports demanding industrial installation environments.\u003c\/li\u003e\n\u003cli\u003eShield continuity helps control electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse compatible Bently Nevada extension cables and Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing and grounding practices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e5. Environmental Resistance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PPS probe tip provides a robust sensing interface.\u003c\/li\u003e\n\u003cli\u003eThe AISI 304 stainless steel case supports industrial installation conditions.\u003c\/li\u003e\n\u003cli\u003eImproved chemical resistance distinguishes the NSv design from the 3300 RAM probe.\u003c\/li\u003e\n\u003cli\u003eThe operating temperature range extends from -52°C to +177°C.\u003c\/li\u003e\n\u003cli\u003eActual chemical compatibility depends on the process medium and exposure conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e6. Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manufacturer does not specify a standalone digital resolution value for this probe. Actual measurement resolution depends on the complete sensing chain, monitor configuration, signal conditioning, and installation conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Number Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330903\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe, M8 x 1 thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-01-\u003c\/td\u003e\n\u003ctd\u003e10 mm unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-07-\u003c\/td\u003e\n\u003ctd\u003e70 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e1.0-meter total probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-12\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003eMultiple agency approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect installation directly affects measurement accuracy and long-term signal stability. Follow these engineering recommendations during installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting preparation:\u003c\/strong\u003e Inspect the M8 x 1 mounting thread and mating surface before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe positioning:\u003c\/strong\u003e Align the probe perpendicular to the target surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap adjustment:\u003c\/strong\u003e Set the initial probe gap to approximately 1.0 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread engagement:\u003c\/strong\u003e Keep the maximum thread engagement within 12 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque control:\u003c\/strong\u003e Follow the applicable probe-case and connector torque specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable routing:\u003c\/strong\u003e Avoid sharp bends, crushing, and excessive mechanical tension.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector protection:\u003c\/strong\u003e Keep the ClickLoc interface clean and properly secured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget inspection:\u003c\/strong\u003e Check the shaft surface for excessive runout, damage, or deposits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe minimum cable bend radius is \u003cstrong\u003e25.4 mm\u003c\/strong\u003e, with or without stainless steel armor. This model uses an unarmored configuration.\u003c\/p\u003e\n\u003cp\u003eThe specified recommended probe torque is finger-tight. The listed maximum torque is 0.56 N·m (5 in·lb). For M8 x 1 probe-case connections, the specified maximum case torque is 7.3 N·m (65 in·lb), with a recommended value of 5.1 N·m (45 in·lb). Confirm the applicable interface before tightening.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300 NSv probe\u003c\/strong\u003e and its compatible extension cable offer mechanical and electrical interchangeability with the previous \u003cstrong\u003e3300 RAM proximity probe system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis compatibility supports selected replacement and maintenance applications. However, engineers should verify the complete system configuration before substituting components.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor sensor:\u003c\/strong\u003e Use the corresponding 3300 XL NSv Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension cable:\u003c\/strong\u003e Select an electrically compatible 75 Ω extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring system:\u003c\/strong\u003e Confirm compatibility with the existing machinery protection channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField wiring:\u003c\/strong\u003e Use three-conductor shielded triad cable where specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum field wiring:\u003c\/strong\u003e Keep the distance between the 3300 XL NSv Proximitor sensor and monitor within 305 meters (1,000 feet).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant electrical characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtension cable center conductor resistance: 0.220 Ω\/m.\u003c\/li\u003e\n\u003cli\u003eExtension cable shield resistance: 0.066 Ω\/m.\u003c\/li\u003e\n\u003cli\u003eTypical extension cable capacitance: 69.9 pF\/m.\u003c\/li\u003e\n\u003cli\u003eRecommended field wire size: 0.2 to 1.5 mm² (16 to 24 AWG).\u003c\/li\u003e\n\u003cli\u003eWith ferrules, use 0.25 to 0.75 mm² (18 to 23 AWG).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume compatibility based on connector appearance alone. Verify probe, extension cable, Proximitor sensor, and monitor specifications as one measurement chain.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApprovals and Product Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAgency approval configuration: \u003cstrong\u003eOption 05, Multiple Approvals\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eProbe material: PPS tip and AISI 304 stainless steel case.\u003c\/li\u003e\n\u003cli\u003eFactory configuration: M8 x 1, unarmored, 1.0-meter cable.\u003c\/li\u003e\n\u003cli\u003eVerify the exact approval markings against the product nameplate and applicable documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eBently Nevada 330903-01-07-10-12-05\u003c\/strong\u003e 3300 NSv Proximity Probe.\u003c\/li\u003e\n\u003cli\u003e1 × Integrated 1.0-meter FluidLoc probe cable.\u003c\/li\u003e\n\u003cli\u003e1 × Miniature coaxial ClickLoc connector.\u003c\/li\u003e\n\u003cli\u003eFactory original packing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePackage contents follow the supplied product configuration. Additional extension cables and accessories require separate confirmation.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the Bently Nevada 330903 probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330903 measures shaft displacement through non-contact eddy-current sensing. It supplies measurement signals for vibration monitoring and machinery protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the recommended installation gap?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe recommended initial gap is 1.0 mm (40 mils). Engineers should verify the final setting against the applicable Proximitor sensor calibration requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this probe replace a 3300 RAM proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv probe offers mechanical and electrical interchangeability with the previous 3300 RAM probe system. Confirm the extension cable and sensor configuration before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should engineers check when vibration readings become unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, inspect the probe gap, cable condition, connector seating, and shield continuity. Then check the extension cable length and sensor compatibility. Avoid changing alarm settings before identifying the signal problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can this probe operate in chemically demanding compressor environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv design provides improved chemical resistance compared with the 3300 RAM probe. Engineers should still verify material compatibility with the actual process chemicals and exposure conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: How should buyers select the correct 3300 NSv probe model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the thread size, unthreaded length, case length, total cable length, connector type, and approval option. Also verify the existing Proximitor sensor and extension cable. Matching every configuration code helps prevent installation and calibration problems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: Does the 330903 include an extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model includes its specified 1.0-meter integral probe cable. A separate extension cable is not identified in the supplied configuration and should be ordered separately when required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: What maintenance checks help extend probe service life?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect cable insulation, connector condition, mounting security, and signal stability during scheduled maintenance. Check for chemical damage and excessive cable bending. Compare readings with historical vibration trends to identify developing faults.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68138672390326,"sku":"330903-01-07-10-12-05","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330903_8_724d8a17-6746-4a27-8420-c7ac3d87b0ca.jpg?v=1795492702","url":"https:\/\/www.plcsparehub.com\/es\/products\/bently-nevada-330903-01-07-10-12-05-3300-nsv-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}