{"product_id":"bently-nevada-330105-xx-xx-05-02-05-3300-xl-reverse-mount-proximity-probe","title":"Bently Nevada 330105-XX-XX-05-02-05 3300 XL Reverse Mount Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eBently Nevada 330105-XX-XX-05-02-05\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 8 mm Reverse Mount Proximity Probe\u003c\/strong\u003e. It measures shaft displacement in rotating machinery. Its reverse-mount configuration supports installations with specific mechanical clearance requirements.\u003c\/p\u003e\n\u003cp\u003eThe probe uses an eddy-current sensing principle to detect the gap between its tip and a conductive target. A compatible Proximitor processes the signal for machinery condition monitoring. Typical applications include turbines, compressors, pumps, and other critical rotating equipment.\u003c\/p\u003e\n\u003cp\u003eThis configuration features a \u003cstrong\u003e0.5-meter probe cable\u003c\/strong\u003e, a \u003cstrong\u003eMiniature ClickLoc coaxial connector\u003c\/strong\u003e, and \u003cstrong\u003eCSA, ATEX, IECEx approvals\u003c\/strong\u003e. Its PPS sensing tip and stainless steel housing support demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Product Identification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330105-XX-XX-05-02-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD 165931-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300 XL 8 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReverse Mount Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 – Miniature ClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 – CSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e2. Electrical and Measurement Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Target\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductive rotating machinery surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.45 ± 0.50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCenter conductor to outer conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetermined by the compatible calibrated measurement system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on the connected Proximitor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on the matched probe and Proximitor system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on complete system calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetermined by monitoring electronics and signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The supplied specifications do not establish numerical measurement range, sensitivity, frequency response, linearity, or resolution. Verify these parameters against the compatible Proximitor and system calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Mechanical and Material Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Thread Engagement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.563 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e323 g\/m (11.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe-to-Lead Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) maximum rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-to-Extension Connector Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N (60 lbf) maximum rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e4. Cable and Connector Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Cable:\u003c\/strong\u003e 75 Ω triaxial cable with FEP insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended-Temperature Cable:\u003c\/strong\u003e 75 Ω triaxial cable with PFA insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Cable Lengths:\u003c\/strong\u003e 0.5, 1, 1.5, 2, 3, 5, and 9 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended-Temperature Cable Lengths:\u003c\/strong\u003e 0.5, 1, 1.5, 2, 5, and 9 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Armor:\u003c\/strong\u003e Flexible AISI 302 or 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor Outer Jacket:\u003c\/strong\u003e FEP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Miniature ClickLoc coaxial.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e5. Environmental and Operating Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Probe Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended-Temperature Probe Tip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +218°C (-62°F to +425°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended-Temperature Cable and Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51°C to +260°C (-60°F to +500°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 3% average scale factor change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Test Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Test Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 56 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Test Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 68-2-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Sealing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton® O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Warning:\u003c\/strong\u003e Temperatures below -34°C (-30°F) may cause premature pressure-seal failure. The probe is not pressure-tested before shipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Engineering Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Shaft Displacement Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300 XL 8 mm probe\u003c\/strong\u003e detects changes in the gap between its sensing tip and a conductive shaft. Compatible Proximitor electronics convert these changes into electrical signals. A monitoring system processes the signals for machinery condition analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Reverse Mount Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe reverse-mount configuration accommodates specific machinery mounting arrangements. It helps engineers address restricted installation clearances. Correct positioning maintains the required probe-to-target relationship.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Stable Signal Transmission\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 75 Ω triaxial cable supports signal transmission between the probe and compatible electronics. Proper cable routing helps reduce unwanted electrical interference. Secure connector engagement also supports reliable signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Industrial Environmental Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PPS tip and stainless steel housing provide mechanical protection. Optional stainless steel armor protects the cable against physical damage. Engineers should select insulation according to actual operating temperatures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the probe tip, housing, cable, and connector before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the mounting thread matches the specified \u003cstrong\u003e3\/8-24 UNF\u003c\/strong\u003e connection.\u003c\/li\u003e\n\u003cli\u003eCheck thread engagement against the 0.563-inch maximum.\u003c\/li\u003e\n\u003cli\u003eInspect the mounting surface and conductive target condition.\u003c\/li\u003e\n\u003cli\u003eInstall the probe according to the equipment manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003eRoute cables away from high-voltage conductors and interference sources.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive cable bending, tension, and sharp mechanical edges.\u003c\/li\u003e\n\u003cli\u003eConnect the probe to compatible extension cables and Proximitor electronics.\u003c\/li\u003e\n\u003cli\u003eVerify the complete measurement chain before machinery startup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e Do not assume a tightening torque. Follow the applicable equipment and probe installation instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Checks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the complete probe model and configuration.\u003c\/li\u003e\n\u003cli\u003eInspect Miniature ClickLoc connectors for contamination or damage.\u003c\/li\u003e\n\u003cli\u003eMeasure probe resistance when required by the maintenance procedure.\u003c\/li\u003e\n\u003cli\u003eConfirm extension cable and Proximitor compatibility.\u003c\/li\u003e\n\u003cli\u003eVerify system calibration and static gap voltage.\u003c\/li\u003e\n\u003cli\u003eCompare vibration readings against established machinery baselines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRoutine Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect cable insulation and optional armor regularly.\u003c\/li\u003e\n\u003cli\u003eCheck connectors for looseness, corrosion, and contamination.\u003c\/li\u003e\n\u003cli\u003eMonitor signal stability during normal machinery operation.\u003c\/li\u003e\n\u003cli\u003eInvestigate unexpected changes in vibration or gap readings.\u003c\/li\u003e\n\u003cli\u003eReplace damaged cables with compatible components.\u003c\/li\u003e\n\u003cli\u003eRecheck system calibration after relevant component replacements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003e330105-XX-XX-05-02-05\u003c\/span\u003e\u003c\/strong\u003e belongs to the \u003cstrong\u003eBently Nevada 3300 XL 8 mm proximity probe family\u003c\/strong\u003e. It requires compatible Proximitor electronics and an appropriate cable configuration.\u003c\/p\u003e\n\u003cp\u003eVerify these parameters before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProbe family: 3300 XL 8 mm.\u003c\/li\u003e\n\u003cli\u003eMounting configuration: Reverse mount.\u003c\/li\u003e\n\u003cli\u003eThread specification: 3\/8-24 UNF.\u003c\/li\u003e\n\u003cli\u003eProbe cable length: 0.5 meter.\u003c\/li\u003e\n\u003cli\u003eConnector configuration: Miniature ClickLoc coaxial.\u003c\/li\u003e\n\u003cli\u003eApproval configuration: CSA, ATEX, IECEx.\u003c\/li\u003e\n\u003cli\u003eTemperature requirements: Standard or extended-temperature configuration.\u003c\/li\u003e\n\u003cli\u003eExtension cable and Proximitor compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Advice:\u003c\/strong\u003e Do not select a replacement based only on probe diameter. Compare the complete part number, mounting arrangement, cable configuration, connector type, and calibration requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\u003c\/strong\u003e – Specified agency approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\u003c\/strong\u003e – Hazardous-area equipment approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx\u003c\/strong\u003e – International hazardous-area certification scheme.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm actual certification markings and installation requirements before using the probe in hazardous areas.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eBently Nevada 330105-XX-XX-05-02-05\u003c\/strong\u003e Reverse Mount Proximity Probe.\u003c\/li\u003e\n\u003cli\u003eConfigured 0.5-meter probe cable.\u003c\/li\u003e\n\u003cli\u003eMiniature ClickLoc coaxial connector.\u003c\/li\u003e\n\u003cli\u003eSpecified agency approval configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe standard package does not automatically include a Proximitor sensor, extension cable, monitoring rack, or mounting accessories. Confirm additional system requirements before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the Bently Nevada 330105 probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe measures the gap between its sensing tip and a conductive target. Compatible Proximitor electronics process the signal for shaft vibration and displacement monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 330105 probe connect directly to a monitoring rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The probe requires compatible Proximitor electronics and an appropriate cable configuration. The Proximitor conditions the probe signal before the monitoring system receives it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when replacing an existing 3300 XL probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete part numbers first. Then verify the mounting thread, probe length, connector, cable type, and system compatibility. A matching diameter alone does not guarantee interchangeability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What causes unstable readings after probe installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCommon causes include incorrect probe gap, loose connectors, damaged cables, and improper calibration. Electrical interference and incompatible cable combinations can also affect signal quality. Inspect the complete measurement chain before replacing the probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can this probe operate continuously at 218°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified extended-temperature probe tip supports temperatures up to 218°C. However, this model description does not independently confirm an extended-temperature cable configuration. Verify the actual cable and connector ratings before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Does the 330105 probe require regular calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe operates as part of a calibrated measurement system. Verify system calibration during commissioning and after relevant component replacements. Follow the applicable machinery protection maintenance procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: How should engineers choose between standard and extended-temperature cable versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelect the cable according to actual operating temperatures near the cable and connector. Standard FEP insulation supports the standard configuration. Extended-temperature PFA insulation supports higher specified temperatures. Check the probe tip and connector temperature limits separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Is the probe suitable for hazardous-area installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration specifies CSA, ATEX, and IECEx approvals. Confirm the actual certification markings, installation method, and system approval requirements before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: What should maintenance engineers check if the probe resistance is outside specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the measurement instrument, connector condition, and cable continuity first. Compare the reading against the specified 7.45 ± 0.50 Ω value for the 0.5-meter configuration. Investigate possible conductor damage before reinstalling the probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: How can buyers avoid selecting an incompatible replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number and existing system configuration. Include the thread size, cable length, connector type, and operating temperature. Technical verification helps prevent unnecessary replacement work.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68155107770550,"sku":"330105-XX-XX-05-02-05 165931-01","price":109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently330105_11_49c5ebf4-f9e7-4a31-a656-029af0d10c9f.jpg?v=1795575899","url":"https:\/\/www.plcsparehub.com\/es\/products\/bently-nevada-330105-xx-xx-05-02-05-3300-xl-reverse-mount-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}