{"product_id":"as3100s2-z0-bently-nevada-accelerometer-100-mv-g-vibration-sensor","title":"AS3100S2-Z0 Bently Nevada Accelerometer – 100 mV\/g Vibration Sensor","description":"\u003ch3\u003e\u003cstrong\u003eAS3100S2-Z0 | Bently Nevada Industrial IEPE Accelerometer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eBently Nevada AS3100S2-Z0\u003c\/span\u003e\u003c\/strong\u003e is an Integrated Electronics Piezo-Electric (IEPE) accelerometer designed for vibration measurement in demanding industrial environments. Its PZT ceramic shear sensing element converts mechanical acceleration into an electrical signal.\u003c\/p\u003e\n\u003cp\u003eAn integrated amplifier conditions the sensor signal and provides a voltage output proportional to acceleration. This architecture supports connection to compatible vibration monitoring and condition monitoring systems through a constant-current power supply.\u003c\/p\u003e\n\u003cp\u003eWith a nominal sensitivity of 100 mV\/g, an acceleration range of 80 g peak, and a specified frequency response extending to 10 kHz at ±3 dB, the sensor supports machinery vibration analysis across a broad measurement range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Measurement Architecture: From Acceleration to Signal Output\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AS3100S2-Z0 uses a piezoelectric shear sensing element and integrated electronics. When the mounting surface vibrates, the PZT element generates an electrical charge proportional to the applied acceleration. The internal amplifier converts this signal into a low-impedance voltage output.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Chain Element\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePZT ceramic shear element\u003c\/td\u003e\n\u003ctd\u003eDetects dynamic mechanical acceleration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated amplifier\u003c\/td\u003e\n\u003ctd\u003eConditions the piezoelectric signal and provides voltage output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstant-current excitation\u003c\/td\u003e\n\u003ctd\u003eSupplies operating power to the IEPE electronics.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output\u003c\/td\u003e\n\u003ctd\u003eProvides an acceleration-proportional signal to compatible monitoring equipment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe IEPE interface reduces sensitivity to electrical interference compared with an unbuffered high-impedance piezoelectric signal. Correct cable shielding, grounding, and excitation remain essential for reliable measurements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Dynamic Performance and Measurement Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe sensor's dynamic specifications define its usable acceleration range, sensitivity, frequency response, and linearity. These values help engineers evaluate its suitability for machinery vibration measurements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDynamic Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal sensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity tolerance\u003c\/td\u003e\n\u003ctd\u003e±5% at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration range\u003c\/td\u003e\n\u003ctd\u003e80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude nonlinearity\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency response, ±10%\u003c\/td\u003e\n\u003ctd\u003e1.0–5,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency response, ±3 dB\u003c\/td\u003e\n\u003ctd\u003e0.7–10,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResonant frequency\u003c\/td\u003e\n\u003ctd\u003e22 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse sensitivity\u003c\/td\u003e\n\u003ctd\u003eMaximum ±5% of axial sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature response at -55 °C\u003c\/td\u003e\n\u003ctd\u003e-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature response at +120 °C\u003c\/td\u003e\n\u003ctd\u003e+10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering interpretation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 100 mV\/g sensitivity converts acceleration into a proportional voltage signal.\u003c\/li\u003e\n\u003cli\u003eThe 80 g peak range defines the specified acceleration measurement limit.\u003c\/li\u003e\n\u003cli\u003eThe ±10% frequency band provides a useful reference for measurement accuracy.\u003c\/li\u003e\n\u003cli\u003eThe wider ±3 dB band describes the sensor's broader frequency response, not a uniform accuracy range.\u003c\/li\u003e\n\u003cli\u003eThe 22 kHz resonance lies above the specified ±3 dB measurement band.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor condition monitoring, select the measurement bandwidth according to the machine's operating speed, bearing characteristics, gear mesh frequencies, and expected fault signatures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | IEPE Electrical Interface and Signal Conditioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe integrated electronics require a compatible constant-current excitation source. The monitoring input must also accept the sensor's bias voltage and dynamic output signal.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent regulating diode\u003c\/td\u003e\n\u003ctd\u003e2–10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput impedance\u003c\/td\u003e\n\u003ctd\u003eMaximum 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBias output voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding arrangement\u003c\/td\u003e\n\u003ctd\u003eCase isolated, internally shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadband electrical noise\u003c\/td\u003e\n\u003ctd\u003e700 μg, 2.5 Hz to 25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral noise at 10 Hz\u003c\/td\u003e\n\u003ctd\u003e10 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral noise at 100 Hz\u003c\/td\u003e\n\u003ctd\u003e5 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral noise at 1,000 Hz\u003c\/td\u003e\n\u003ctd\u003e5 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSignal scaling example:\u003c\/strong\u003e At 100 mV\/g sensitivity, an acceleration of 1 g produces a nominal 100 mV dynamic signal. An acceleration of 5 g produces approximately 500 mV, subject to the sensor's operating range and signal conditioning.\u003c\/p\u003e\n\u003cp\u003eThe 12 VDC bias output is the sensor's normal operating bias, not the acceleration signal amplitude. Monitoring equipment should account for this bias when measuring the dynamic voltage component.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Mechanical Construction and Installation Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe sensor uses a corrosion-resistant 316L stainless steel case and a hermetically sealed construction. Its compact mounting arrangement supports permanent installation on machinery and access-limited measurement locations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePhysical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing element\u003c\/td\u003e\n\u003ctd\u003ePZT ceramic, shear design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting arrangement\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 captive hex-head screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector position\u003c\/td\u003e\n\u003ctd\u003eSide exit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015 style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eHermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation guidance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eChoose a rigid measurement location close to the vibration source.\u003c\/li\u003e\n\u003cli\u003ePrepare a clean, flat mounting surface to improve mechanical coupling.\u003c\/li\u003e\n\u003cli\u003eCheck the mounting thread and screw engagement before tightening.\u003c\/li\u003e\n\u003cli\u003eSecure the sensor using the approved mounting procedure and torque specification.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from moving components, hot surfaces, and high-current conductors.\u003c\/li\u003e\n\u003cli\u003eConfirm connector engagement and cable shielding before collecting data.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eA loose mounting interface can reduce high-frequency response and introduce measurement errors. Avoid mounting the sensor on thin covers or flexible brackets when measuring bearing or housing vibration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Connector Pinout and Cable Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe side-exit connector uses a two-pin MIL-C-5015-style interface. Correct pin assignment is essential for sensor power and signal acquisition.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Contact\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin A\u003c\/td\u003e\n\u003ctd\u003ePower \/ Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin B\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended cable:\u003c\/strong\u003e Use shielded twisted-pair cable with a maximum recommended length of 100 feet.\u003c\/p\u003e\n\u003cp\u003eKeep the cable shield and grounding arrangement consistent with the monitoring system's input design. Avoid unnecessary ground connections that could create ground-loop currents. The sensor's case isolation and internal shielding help reduce this risk, but they do not replace correct system grounding.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Environmental Limits and Industrial Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AS3100S2-Z0 is designed for harsh industrial environments. Its mechanical construction and electrical protection features support installation near operating machinery.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-50 °C to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration limit\u003c\/td\u003e\n\u003ctd\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock limit\u003c\/td\u003e\n\u003ctd\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic sensitivity\u003c\/td\u003e\n\u003ctd\u003eMaximum 70 μg\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase strain sensitivity\u003c\/td\u003e\n\u003ctd\u003eMaximum 0.002 g\/μstrain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eHermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProtection features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCorrosion-resistant stainless steel construction.\u003c\/li\u003e\n\u003cli\u003eHermetic sealing against environmental ingress.\u003c\/li\u003e\n\u003cli\u003eCase isolation to help prevent ground-loop problems.\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge protection.\u003c\/li\u003e\n\u003cli\u003eReverse-wiring protection.\u003c\/li\u003e\n\u003cli\u003eEMI and RFI shielding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe sensor can support washdown or submersion applications when used with a properly rated connector and cable assembly. Confirm the complete connection system's environmental rating before exposure to water.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Machinery Monitoring Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IEPE output allows the sensor to interface with compatible vibration data collectors and permanent monitoring systems. Engineers can use acceleration measurements to investigate machine condition and dynamic behavior.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating machinery:\u003c\/strong\u003e Measure casing and housing acceleration on pumps, motors, compressors, and fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBearing diagnostics:\u003c\/strong\u003e Capture higher-frequency vibration components associated with bearing condition assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGearbox monitoring:\u003c\/strong\u003e Measure dynamic acceleration around gear housings and transmission structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable vibration routes:\u003c\/strong\u003e Use the relatively low 145 g sensor mass for walk-around measurement programs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermanent installations:\u003c\/strong\u003e Use the case-isolated design to help reduce ground-loop issues in suitable monitoring arrangements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor accurate trend comparison, keep sensor location, mounting method, cable routing, and measurement settings consistent across inspection intervals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Selection and Compatibility Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AS3100 series includes different sensitivity levels, connector orientations, and hazardous-area certification options. Confirm the exact configuration before selecting a replacement or adding a measurement point.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Factor\u003c\/th\u003e\n\u003cth\u003eAS3100S2-Z0 Information\u003c\/th\u003e\n\u003cth\u003eVerification Required\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g\u003c\/td\u003e\n\u003ctd\u003eMatch the monitoring input scaling and required measurement range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector orientation\u003c\/td\u003e\n\u003ctd\u003eSide exit\u003c\/td\u003e\n\u003ctd\u003eCheck cable clearance and installation access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015 style\u003c\/td\u003e\n\u003ctd\u003eConfirm connector and cable assembly compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC, 2–10 mA\u003c\/td\u003e\n\u003ctd\u003eVerify constant-current IEPE input support.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous-area approval\u003c\/td\u003e\n\u003ctd\u003eSeries offers different certification options\u003c\/td\u003e\n\u003ctd\u003eConfirm the exact approval for the -Z0 configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e0.7–10,000 Hz at ±3 dB\u003c\/td\u003e\n\u003ctd\u003eCompare with the required diagnostic bandwidth.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant model-code note:\u003c\/strong\u003e The supplied data describes the AS3100 series and identifies the AS3100S2-Z0 as a 100 mV\/g, side-exit configuration. It does not specify the exact hazardous-area approval represented by the -Z0 suffix. Do not assign an ATEX, IECEx, or other certification to this exact model without checking its product-specific documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Field Diagnostics and Measurement Quality\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnexpected vibration readings may result from the machine, sensor mounting, cable condition, or signal-conditioning circuit. Check the complete measurement chain before concluding that the sensor has failed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat or missing signal:\u003c\/strong\u003e Verify IEPE excitation, cable continuity, connector pin assignment, and monitoring input configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcessive electrical noise:\u003c\/strong\u003e Inspect shield termination, cable routing, grounding, and nearby variable-frequency drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow measured amplitude:\u003c\/strong\u003e Check mounting rigidity, sensor orientation, sensitivity scaling, and signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnstable baseline:\u003c\/strong\u003e Inspect the bias voltage and cable connection. Compare the measured bias with the specified nominal 12 VDC value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInconsistent high-frequency readings:\u003c\/strong\u003e Review mounting surface quality, attachment rigidity, cable movement, and acquisition bandwidth.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a repeatable baseline, document the sensor location, mounting arrangement, cable type, excitation current, and analyzer settings. This makes trend changes easier to distinguish from measurement setup variations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I convert the AS3100S2-Z0 voltage output into acceleration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the nominal sensitivity of 100 mV\/g. Subtract the DC bias component from the measured signal, then divide the dynamic voltage by 100 mV\/g. For example, a 200 mV dynamic signal represents approximately 2 g. Apply the correct analyzer scaling and account for the stated sensitivity tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I connect this sensor directly to a standard voltage input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly if the input supports the required IEPE constant-current excitation and can accommodate the sensor's bias voltage. A conventional voltage input without excitation may not power the integrated amplifier. Check the monitoring instrument's IEPE input specifications before connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why does sensor mounting affect high-frequency vibration measurements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe mounting interface forms part of the mechanical measurement path. Uneven surfaces, loose fasteners, flexible brackets, or poor contact can reduce the transmitted vibration energy. Use a rigid mounting point and follow the approved mounting procedure to maintain measurement consistency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should I consider when replacing a 500 mV\/g accelerometer with this 100 mV\/g model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the analyzer's sensitivity setting, input range, signal scaling, and expected acceleration amplitude. At the same acceleration, a 100 mV\/g sensor produces one-fifth the voltage of a 500 mV\/g sensor. Confirm that the new signal level remains suitable for the monitoring system's noise floor and dynamic range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How can I distinguish sensor failure from a cable or input-channel fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the connector and cable first. Verify the constant-current supply and measure the sensor bias voltage using an appropriate test arrangement. If possible, compare the sensor with a known-good channel or compatible sensor. Change one component at a time to isolate the fault without altering the measurement setup unnecessarily.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/AS3100S2-Z0.png?v=1795489431\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68129187659958,"sku":"AS3100S2-Z0","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/AS3100S2-Z0.jpg?v=1795489431","url":"https:\/\/www.plcsparehub.com\/es\/products\/as3100s2-z0-bently-nevada-accelerometer-100-mv-g-vibration-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}