{"product_id":"728a13tce2fa-mks-instruments-728a-heated-capacitance-manometer","title":"728A13TCE2FA MKS Instruments 728A Heated Capacitance Manometer","description":"\u003ch3\u003e\u003cb\u003eProduct Overview | Heated Absolute Pressure Technology\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d97706;\"\u003eMKS Instruments 728A13TCE2FA\u003c\/span\u003e\u003c\/strong\u003e belongs to the MKS 728A Baratron® heated capacitance manometer series. It measures absolute pressure through a precision capacitive diaphragm sensing element.\u003c\/p\u003e\n\u003cp\u003eThe instrument maintains its sensor temperature at \u003cstrong\u003e100°C\u003c\/strong\u003e. This controlled heating helps reduce process gas condensation and material deposition inside the sensing assembly.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e1000 Torr full-scale range\u003c\/strong\u003e supports pressure monitoring in semiconductor manufacturing and industrial vacuum processes. The all-Inconel® wetted construction provides strong resistance to corrosive process gases and chemical by-products.\u003c\/p\u003e\n\u003cp\u003eThe specified configuration includes an \u003cstrong\u003e8 VCR female fitting\u003c\/strong\u003e and a proportional 0–10 VDC analog output. Its response time is less than 75 ms, supporting dynamic pressure monitoring and process feedback.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Model Configuration \u0026amp; Ordering Code Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Model: \u003cspan style=\"color: #d97706;\"\u003e728A13TCE2FA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Meaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e728A\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHeated absolute Baratron® capacitance manometer, 100°C sensor temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13T\u003c\/td\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e1000 Torr full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eVacuum Fitting\u003c\/td\u003e\n\u003ctd\u003e8 VCR female connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eElectrical Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard ±15 VDC supply and 0–10 VDC analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eAccuracy Code\u003c\/td\u003e\n\u003ctd\u003e0.50% of Reading, subject to configuration confirmation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eConnector Code\u003c\/td\u003e\n\u003ctd\u003e9-pin D-sub according to supplied ordering information; verify against original product documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Identification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e728A:\u003c\/strong\u003e Identifies the heated sensor platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e13T:\u003c\/strong\u003e Defines the 1000 Torr pressure range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Specifies the 8 VCR female vacuum connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2:\u003c\/strong\u003e Defines the standard power and analog output configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFA:\u003c\/strong\u003e Identifies the stated accuracy and connector configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Warning:\u003c\/strong\u003e The supplied technical description for 728A13TCE2FB specifies a 15-pin D-sub connector. Do not substitute that connector specification for the requested FA configuration without checking the original MKS ordering documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | Technical Data Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #d97706;\"\u003e728A13TCE2FA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e728A Baratron® Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeated Absolute Capacitance Manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure Transducer \/ Vacuum Gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitance diaphragm sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 133.32 kPa \/ 1.333 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.50% of Reading, 10–1000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 75 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.010% of Full Scale\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpan Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.040% of Full Scale\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpressure Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 psia or 2 × Full Scale, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 × Full Scale or 90 psi, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInconel®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature controlled at 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e03 | Thermal Management \u0026amp; Process Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe heated sensing assembly maintains a controlled temperature of 100°C. This design helps minimize condensation and deposition from process gases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Performance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.010% FS\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpan Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.040% FS\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintains a controlled sensing temperature.\u003c\/li\u003e\n\u003cli\u003eHelps reduce condensation inside the measurement assembly.\u003c\/li\u003e\n\u003cli\u003eLimits process residue accumulation under suitable operating conditions.\u003c\/li\u003e\n\u003cli\u003eSupports stable measurement in heated vacuum process environments.\u003c\/li\u003e\n\u003cli\u003eReduces measurement disturbances associated with temperature-sensitive process deposits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e04 | Pressure Measurement \u0026amp; Protection Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe capacitive diaphragm responds to pressure changes. Its movement changes the electrical capacitance within the sensing element.\u003c\/p\u003e\n\u003cp\u003eThe electronics convert this capacitance variation into a proportional pressure signal. The absolute measurement reference supports consistent pressure monitoring independent of atmospheric pressure changes.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Torr Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.50% of Reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;75 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpressure Protection Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 psia or 2 × FS, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 × FS or 90 psi, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Overpressure tolerance and burst pressure describe different limits. Neither value represents a normal operating pressure rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Electrical Interface \u0026amp; Signal Output\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear proportional analog signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD-subminiature; exact pin count requires FA configuration verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Information for FB Variant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin Type D, according to supplied FB description\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe analog output supports integration with compatible pressure controllers, monitoring instruments, and process automation systems.\u003c\/p\u003e\n\u003cp\u003eVerify the electrical pinout before connecting the instrument. Do not assume that the FA and FB connector arrangements are interchangeable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Vacuum Connection \u0026amp; Wetted Construction\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVacuum Fitting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 VCR Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFitting Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInconel® Nickel Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll-metal sensing structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSealing Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal face-seal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Inconel® construction provides high corrosion resistance against many process gases and chemical by-products. The 8 VCR female connection supports metal-sealed vacuum installations.\u003c\/p\u003e\n\u003cp\u003eEngineers should verify fitting dimensions, compatible gasket materials, and process chemical compatibility before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Installation \u0026amp; Commissioning Procedure\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the 1000 Torr pressure range matches the process requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the 8 VCR female connection against the chamber port.\u003c\/li\u003e\n\u003cli\u003eInspect sealing surfaces for scratches and contamination.\u003c\/li\u003e\n\u003cli\u003eUse compatible VCR sealing components.\u003c\/li\u003e\n\u003cli\u003eInstall the gauge without introducing excessive mechanical stress.\u003c\/li\u003e\n\u003cli\u003eCheck the process connection for leakage after assembly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePrepare the required ±15 VDC power supply.\u003c\/li\u003e\n\u003cli\u003eConfirm the exact connector configuration for the FA suffix.\u003c\/li\u003e\n\u003cli\u003eCheck the connector pin assignment against the manufacturer diagram.\u003c\/li\u003e\n\u003cli\u003eConnect the 0–10 VDC output to a compatible analog input.\u003c\/li\u003e\n\u003cli\u003eVerify the signal reference and grounding arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the pressure reading after thermal stabilization.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Consideration:\u003c\/strong\u003e Allow the heated sensor to reach its specified operating temperature before evaluating measurement stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Calibration, Maintenance \u0026amp; Troubleshooting\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInspection Direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure reading drift\u003c\/td\u003e\n\u003ctd\u003eCheck zero stability and thermal conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlow signal response\u003c\/td\u003e\n\u003ctd\u003eInspect process connection and signal acquisition settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable analog output\u003c\/td\u003e\n\u003ctd\u003eCheck power quality, grounding, and connector contacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected pressure offset\u003c\/td\u003e\n\u003ctd\u003eVerify the reference pressure and calibration condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess contamination\u003c\/td\u003e\n\u003ctd\u003eReview process deposits and cleaning requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating abnormality\u003c\/td\u003e\n\u003ctd\u003eCheck the heating system and manufacturer service instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Recommendations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor zero and span stability at scheduled intervals.\u003c\/li\u003e\n\u003cli\u003eInspect the VCR sealing interface during maintenance.\u003c\/li\u003e\n\u003cli\u003eCheck the electrical connector for damage or contamination.\u003c\/li\u003e\n\u003cli\u003eCompare pressure readings against a calibrated reference.\u003c\/li\u003e\n\u003cli\u003eReview thermal stabilization before adjusting zero settings.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer's service procedures for internal maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e09 | Controller Compatibility \u0026amp; System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d97706;\"\u003eMKS 728A13TCE2FA\u003c\/span\u003e\u003c\/strong\u003e provides a 0–10 VDC pressure signal and requires a compatible ±15 VDC supply.\u003c\/p\u003e\n\u003cp\u003eThe supplied application information identifies the following MKS instruments as potential system partners:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMKS PR4000B:\u003c\/strong\u003e Pressure controller and readout integration, subject to configuration verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMKS PDR2000A:\u003c\/strong\u003e Pressure display and power interface, subject to connector and signal compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Analog Input Modules:\u003c\/strong\u003e Compatible voltage input channels with suitable signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Process Controllers:\u003c\/strong\u003e Systems that support the specified analog output and power requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore integration, verify power supply capacity, signal scaling, connector pinout, and controller input specifications. Similar product names do not guarantee direct electrical compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Manufacturing:\u003c\/strong\u003e Monitors absolute pressure in process chambers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Vapor Deposition:\u003c\/strong\u003e Provides pressure feedback during CVD operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Vapor Deposition:\u003c\/strong\u003e Supports vacuum pressure monitoring during coating processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Coating Systems:\u003c\/strong\u003e Measures chamber pressure during industrial deposition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Gas Systems:\u003c\/strong\u003e Monitors pressure in compatible corrosive gas environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Equipment Retrofits:\u003c\/strong\u003e Supports upgrades to existing pressure measurement systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e11 | Product Supply, Warranty \u0026amp; Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e728A13TCE2FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e728A Heated Absolute Baratron® Capacitance Manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew \u0026amp; Original in Factory Packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory Warranty: 12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelivery Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternational shipping options available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Packaging List:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × MKS Instruments 728A13TCE2FA Heated Capacitance Manometer.\u003c\/li\u003e\n\u003cli\u003eProtective transportation packaging.\u003c\/li\u003e\n\u003cli\u003eProduct identification and configuration information, where supplied.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our sales team to confirm stock, connector configuration, delivery time, and quotation details.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Why does a heated Baratron gauge operate at 100°C instead of ambient temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProcess gases can condense or leave deposits on cooler internal surfaces. Maintaining the sensing assembly at 100°C helps reduce these effects. This is particularly useful in processes involving condensable precursors and reactive chemical by-products. The process temperature and gas chemistry must still remain within the instrument's compatibility limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How should engineers interpret the zero and span temperature coefficients?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe zero coefficient describes temperature-related changes in the zero-pressure reference. The span coefficient describes changes in measurement sensitivity. Both values affect measurement performance when ambient conditions change. Engineers should consider these coefficients when designing calibration intervals and pressure measurement uncertainty budgets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can the 728A13TCE2FA replace a non-heated 626D series gauge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. The 728A uses a heated sensing assembly, while the 626D is an unheated design. Their pressure ranges, fittings, electrical connectors, and controller requirements may differ. Compare the complete mechanical and electrical configurations before selecting a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What practical checks help prevent inaccurate readings during semiconductor process commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck flange cleanliness, metal sealing integrity, power supply stability, and signal grounding. Allow sufficient time for the sensor to reach thermal equilibrium. Then compare the output against a calibrated reference instrument. Also verify that process deposits do not obstruct the pressure connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. How should buyers choose between the FA and FB configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the original equipment part number and manufacturer ordering documentation. Compare connector pin count, cable assembly, accuracy code, power configuration, and vacuum fitting. The supplied FB description identifies a 15-pin D-sub connector, while the supplied FA description identifies a 9-pin connector. Obtain confirmation from the nameplate or manufacturer documentation before purchasing either version.\u003c\/p\u003e","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":68142106280118,"sku":"728A13TCE2FA","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/728A13TCE2FA-1.jpg?v=1795504641","url":"https:\/\/www.plcsparehub.com\/es\/products\/728a13tce2fa-mks-instruments-728a-heated-capacitance-manometer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}