{"product_id":"722b12tcd2fa-mks-instruments-4-vcr-precision-pressure-sensor","title":"722B12TCD2FA MKS Instruments 4-VCR Precision Pressure Sensor","description":"\n\u003ch3\u003e\u003cstrong\u003eProduct Overview | Compact Absolute Pressure Measurement\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677A8;\"\u003eMKS Instruments 722B12TCD2FA\u003c\/span\u003e\u003c\/strong\u003e is a compact absolute pressure transducer from the \u003cstrong\u003eBaratron® 722B Series\u003c\/strong\u003e. It uses capacitance diaphragm technology to measure vacuum and process pressure independently of gas composition.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration provides a \u003cstrong\u003e100 Torr full-scale range\u003c\/strong\u003e and \u003cstrong\u003e±0.5% of reading accuracy\u003c\/strong\u003e. Its process interface uses a female 4-VCR fitting. A 9-pin Type D connector handles power and analog signal connections.\u003c\/p\u003e\n\n\u003cp\u003eThe transducer accepts \u003cstrong\u003e+13 to +32 VDC\u003c\/strong\u003e and provides a proportional \u003cstrong\u003e0–10 VDC output\u003c\/strong\u003e. Its all-metal wetted construction uses Inconel® for compatibility with many industrial process gases.\u003c\/p\u003e\n\n\u003cp\u003eA response time below 20 milliseconds supports dynamic pressure monitoring. The robust sensor construction also tolerates specified pressure excursions. These characteristics make the \u003cstrong\u003e722B12TCD2FA\u003c\/strong\u003e suitable for vacuum equipment, semiconductor systems, and industrial process monitoring.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Breakdown – Model Suffix Analysis\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe complete ordering code identifies the pressure range, process fitting, electrical configuration, accuracy, and connector. Each suffix defines a specific hardware requirement.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Meaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e722B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eCompact general-purpose absolute Baratron® capacitance manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e100 Torr full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess Fitting\u003c\/td\u003e\n\u003ctd\u003e1\/4-inch 4-VCR female connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput \/ Output\u003c\/td\u003e\n\u003ctd\u003e+13 to +32 VDC input \/ 0–10 VDC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy Grade\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e9-pin Type D connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eComplete Model:\u003c\/strong\u003e \u003cspan style=\"color: #1677A8;\"\u003e\u003cstrong\u003e722B12TCD2FA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration Architecture:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Measurement:\u003c\/strong\u003e 100 Torr absolute pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Connection:\u003c\/strong\u003e Female 4-VCR process fitting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Architecture:\u003c\/strong\u003e Single positive DC supply, +13 to +32 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Architecture:\u003c\/strong\u003e 0–10 VDC proportional analog output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e ±0.5% of reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e 9-pin D-subminiature connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration Distinction:\u003c\/strong\u003e The CD suffix specifies 4-VCR female. The CE suffix specifies 8-VCR female. These fittings are not interchangeable, so verify the complete ordering code before purchasing.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e02 | Technical Specification Register\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments, USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e722B12TCD2FA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eBaratron® 722B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCapacitance Diaphragm Pressure Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eAbsolute Pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Output Load\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+13 to +32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Supply Current\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Fitting\u003c\/td\u003e\n\u003ctd\u003e1\/4-inch 4-VCR female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e9-pin Type D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Material\u003c\/td\u003e\n\u003ctd\u003eInconel®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Surface Finish\u003c\/td\u003e\n\u003ctd\u003e≤10 Ra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.008% F.S.\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.04% of reading\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure Limit\u003c\/td\u003e\n\u003ctd\u003e45 psia or 2 × F.S., whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurst Pressure\u003c\/td\u003e\n\u003ctd\u003e10 × F.S. or 100 psi, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003e03 | Sensing Technology and Measurement Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBaratron® 722B\u003c\/strong\u003e measures pressure through capacitive changes in a precision diaphragm assembly.\u003c\/p\u003e\n\n\u003cp\u003ePressure acts on the sensing diaphragm and produces mechanical displacement. The internal electronics convert the resulting capacitance variation into a proportional voltage signal.\u003c\/p\u003e\n\n\u003cp\u003eThis measurement method offers several engineering advantages:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas-Independent Measurement:\u003c\/strong\u003e The sensing principle does not depend on gas thermal conductivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Pressure Reference:\u003c\/strong\u003e Measures pressure against an internal reference vacuum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Response:\u003c\/strong\u003e The specified response time remains below 20 milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Measurement:\u003c\/strong\u003e The accuracy specification includes non-linearity, hysteresis, and non-repeatability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e Inconel® wetted surfaces support compatibility with many process gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean Surface Construction:\u003c\/strong\u003e Wetted surfaces receive a controlled finish of ≤10 Ra.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccuracy Definition:\u003c\/strong\u003e The ±0.5% specification refers to the pressure reading. It does not represent ±0.5% of full scale.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e04 | Analog Output and Electrical Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e722B12TCD2FA\u003c\/strong\u003e uses a 0–10 VDC output for integration with compatible pressure controllers and industrial analog input systems.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e+13 to +32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e10 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e9-pin Type D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Reference\u003c\/td\u003e\n\u003ctd\u003ePressure Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Reference\u003c\/td\u003e\n\u003ctd\u003ePower Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eNominal Signal Scaling:\u003c\/strong\u003e The 100 Torr full-scale range corresponds to a 0–10 VDC output.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e0 Torr corresponds to approximately 0 VDC.\u003c\/li\u003e\n\u003cli\u003e25 Torr corresponds to approximately 2.5 VDC.\u003c\/li\u003e\n\u003cli\u003e50 Torr corresponds to approximately 5 VDC.\u003c\/li\u003e\n\u003cli\u003e75 Torr corresponds to approximately 7.5 VDC.\u003c\/li\u003e\n\u003cli\u003e100 Torr corresponds to approximately 10 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese values represent nominal linear scaling. Actual readings depend on calibration and instrument specifications.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e05 | 9-Pin D-Sub Connector Pin Assignment\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe following pinout follows the MKS 722B instruction manual. Keep the pressure signal return and power return connections distinct during cable assembly.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Assignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003ePressure Output\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC analog pressure signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eNo Connection\u003c\/td\u003e\n\u003ctd\u003eNot internally connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 3\u003c\/td\u003e\n\u003ctd\u003eNo Connection\u003c\/td\u003e\n\u003ctd\u003eNot internally connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 4\u003c\/td\u003e\n\u003ctd\u003e+ Power Input\u003c\/td\u003e\n\u003ctd\u003e+13 to +32 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 5\u003c\/td\u003e\n\u003ctd\u003eNo Connection\u003c\/td\u003e\n\u003ctd\u003eNot internally connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 6\u003c\/td\u003e\n\u003ctd\u003eNo Connection\u003c\/td\u003e\n\u003ctd\u003eNot internally connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 7\u003c\/td\u003e\n\u003ctd\u003eNo Connection\u003c\/td\u003e\n\u003ctd\u003eNot internally connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 8\u003c\/td\u003e\n\u003ctd\u003ePressure Return\u003c\/td\u003e\n\u003ctd\u003eAnalog signal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 9\u003c\/td\u003e\n\u003ctd\u003ePower Return\u003c\/td\u003e\n\u003ctd\u003eDC supply return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eWiring Precaution:\u003c\/strong\u003e Do not assume that pressure return and power return are interchangeable. Follow the MKS wiring diagram and compatible controller requirements.\u003c\/p\u003e\n\n\u003cp\u003eVerify connector orientation before assigning pin numbers. Incorrect wiring can cause unstable readings or damage connected equipment.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e06 | Pressure Limits and Thermal Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe sensor construction supports pressure excursions beyond its normal measurement range. Engineers must distinguish the specified overpressure limit from the burst pressure rating.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Pressure\u003c\/td\u003e\n\u003ctd\u003e100 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure Limit\u003c\/td\u003e\n\u003ctd\u003e45 psia or 2 × full scale, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurst Pressure\u003c\/td\u003e\n\u003ctd\u003e10 × full scale or 100 psi, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.008% F.S.\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.04% of reading\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e Overpressure tolerance does not authorize continuous operation above the rated measurement range. Avoid unnecessary pressure surges during system venting and pump-down.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e07 | Vacuum Connection and Wetted Material\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eCD fitting configuration\u003c\/strong\u003e provides a female 4-VCR process interface. It supports compatible metal-gasket vacuum connections.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitting Type:\u003c\/strong\u003e 1\/4-inch 4-VCR female.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted Material:\u003c\/strong\u003e Inconel® nickel-based alloy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Finish:\u003c\/strong\u003e ≤10 Ra on wetted surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e All-metal sensor wetted surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Compatibility:\u003c\/strong\u003e Suitable for many compatible semiconductor and industrial process gases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSome optional fitting configurations use 316 stainless steel. The standard wetted sensor surfaces use Inconel®. Confirm the actual fitting material when chemical compatibility is critical.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Warning:\u003c\/strong\u003e Use compatible VCR gaskets and approved assembly procedures. Do not apply excessive tightening force to the fitting or sensor body.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e08 | Installation and Commissioning Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eProper installation protects the sensing diaphragm and maintains vacuum system integrity. Complete the following checks before applying operating pressure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMechanical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eVerify the 4-VCR female connection against the process tubing.\u003c\/li\u003e\n\u003cli\u003eInspect the sealing surfaces before installing the gasket.\u003c\/li\u003e\n\u003cli\u003eUse compatible metal gaskets for the process conditions.\u003c\/li\u003e\n\u003cli\u003eCheck the mounting position and avoid unnecessary mechanical stress.\u003c\/li\u003e\n\u003cli\u003eInspect all vacuum joints for leakage after assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectrical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eProvide a regulated +13 to +32 VDC supply.\u003c\/li\u003e\n\u003cli\u003eConnect the positive supply to Pin 4.\u003c\/li\u003e\n\u003cli\u003eConnect the power return to Pin 9.\u003c\/li\u003e\n\u003cli\u003eConnect the analog output through Pin 1.\u003c\/li\u003e\n\u003cli\u003eConnect the pressure return through Pin 8.\u003c\/li\u003e\n\u003cli\u003eVerify the receiving input impedance exceeds 10 kΩ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommissioning Sequence\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003eInspect the complete electrical and vacuum connections.\u003c\/li\u003e\n\u003cli\u003eVerify the power supply voltage and polarity.\u003c\/li\u003e\n\u003cli\u003eAllow the instrument to reach stable operating conditions.\u003c\/li\u003e\n\u003cli\u003eCheck the analog output at a known pressure.\u003c\/li\u003e\n\u003cli\u003eCompare readings against a calibrated reference instrument.\u003c\/li\u003e\n\u003cli\u003eConfigure the PLC or controller for a 0–100 Torr range.\u003c\/li\u003e\n\u003cli\u003ePerform a final leak and signal stability check.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003e09 | Maintenance and Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe compact sensor architecture simplifies integration into vacuum equipment. Routine checks should focus on pressure connections, power quality, and analog signal integrity.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObserved Problem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Inspection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput remains at zero\u003c\/td\u003e\n\u003ctd\u003eCheck supply voltage, Pin 4, Pin 9, and pressure conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput fluctuates unexpectedly\u003c\/td\u003e\n\u003ctd\u003eInspect grounding, shielding, and analog input stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading differs from reference\u003c\/td\u003e\n\u003ctd\u003eVerify calibration, temperature, and controller scaling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure does not stabilize\u003c\/td\u003e\n\u003ctd\u003eInspect vacuum joints, process leakage, and pump performance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect PLC reading\u003c\/td\u003e\n\u003ctd\u003eCheck signal return, input impedance, and 0–10 V configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSudden measurement shift\u003c\/td\u003e\n\u003ctd\u003eInvestigate pressure surges and abnormal process conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaintenance Recommendation:\u003c\/strong\u003e Inspect the VCR sealing interface whenever technicians disconnect the sensor. Replace damaged sealing components and repeat the leak test after reassembly.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e10 | System Compatibility and Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eMKS Baratron 722B\u003c\/strong\u003e supports vacuum control systems with compatible DC power and voltage-input measurement channels.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Systems:\u003c\/strong\u003e Use a 0–10 VDC analog input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Systems:\u003c\/strong\u003e Connect through a compatible voltage signal acquisition channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Controllers:\u003c\/strong\u003e Integrate with controllers supporting the 722B electrical interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e Monitor absolute pressure in compatible process chambers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Process Equipment:\u003c\/strong\u003e Provide pressure feedback for monitoring and control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatibility Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eVerify the +13 to +32 VDC supply requirement.\u003c\/li\u003e\n\u003cli\u003eConfirm the controller accepts a 0–10 VDC signal.\u003c\/li\u003e\n\u003cli\u003eMaintain an input impedance above 10 kΩ.\u003c\/li\u003e\n\u003cli\u003eMatch the female 4-VCR fitting with the process connection.\u003c\/li\u003e\n\u003cli\u003eConfirm the 9-pin D-sub pinout before cable fabrication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDo not connect the output directly to a 4–20 mA input. Use an appropriate signal converter when the existing control system lacks voltage-input capability.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e11 | Typical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Manufacturing:\u003c\/strong\u003e Monitor vacuum pressure in compatible process chambers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin-Film Deposition:\u003c\/strong\u003e Provide pressure feedback during vacuum coating operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Processing:\u003c\/strong\u003e Measure absolute pressure in industrial vacuum equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch Laboratories:\u003c\/strong\u003e Support controlled pressure measurement in experimental systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Equipment Integration:\u003c\/strong\u003e Supply analog pressure signals to automation controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Monitoring:\u003c\/strong\u003e Track pressure changes during production and equipment operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e12 | Product Selection and Replacement Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eWhen selecting a replacement for an existing Baratron® transducer, compare the complete ordering code rather than the series name alone.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Criteria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e722B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e100 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitting\u003c\/td\u003e\n\u003ctd\u003e4-VCR female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e+13 to +32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e9-pin Type D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant Selection Distinction:\u003c\/strong\u003e The 722B12TCD2FA and 722B12TCE2FA share the 100 Torr range and electrical configuration. However, CD specifies 4-VCR female, while CE specifies 8-VCR female.\u003c\/p\u003e\n\n\u003cp\u003eDo not substitute these configurations without checking the process connection. Also verify the power supply and controller scaling when replacing older pressure transducers.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e13 | Packaging, Warranty and International Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e MKS Instruments 722B12TCD2FA Baratron® Pressure Transducer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e 100 Torr, 4-VCR female, 0–10 VDC output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e 9-pin D-sub connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective packaging for precision industrial instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Product identification and available technical documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eShipping Options:\u003c\/strong\u003e FedEx, UPS, and DHL international delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Condition:\u003c\/strong\u003e New and original factory-supplied equipment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOrdering Note:\u003c\/strong\u003e Confirm the fitting, connector, and complete model suffix before ordering. Cables, gaskets, controllers, and additional accessories require separate confirmation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e14 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 722B12TCD2FA measure pressure when the process gas composition changes?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. Its capacitance diaphragm principle measures pressure through mechanical displacement rather than gas thermal conductivity. Changes between compatible process gases do not require thermal conductivity correction factors. Engineers must still evaluate chemical compatibility with exposed materials.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why is the separation between pressure return and power return important?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThese connections serve different electrical functions. Pin 8 provides the pressure signal reference. Pin 9 provides the power return. Incorrect grounding arrangements can introduce measurement errors or damage connected equipment. Follow the specified interface diagram during cable fabrication.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How should engineers evaluate pressure spikes during pump switching?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMonitor pressure changes during pump startup, isolation valve operation, and chamber venting. Compare transient pressure against the specified overpressure limit. The protective rating helps tolerate occasional excursions, but it does not replace proper pressure management.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Can a 100 Torr transducer replace a 250 Torr or 500 Torr model?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNot automatically. A lower full-scale range changes the pressure-to-voltage relationship and the available measurement span. Check the maximum process pressure and controller scaling before substitution. Select a range that accommodates normal operation and expected pressure excursions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What should purchasing engineers verify when ordering a replacement for a CD or CE configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCheck the exact VCR fitting size, connector type, output voltage, and power requirement. CD identifies 4-VCR female, while CE identifies 8-VCR female. Request confirmation using the complete nameplate model number. This check helps prevent mechanical installation problems and unnecessary system modifications.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePrecision Baratron Pressure Measurement for Vacuum Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677A8;\"\u003eMKS Instruments 722B12TCD2FA\u003c\/span\u003e\u003c\/strong\u003e combines 100 Torr absolute pressure measurement with ±0.5% reading accuracy and a compact capacitance diaphragm design.\u003c\/p\u003e\n\n\u003cp\u003eIts female 4-VCR process connection, 9-pin D-sub interface, and 0–10 VDC output support integration into compatible vacuum equipment. Inconel® wetted surfaces and fast response make this configuration suitable for demanding industrial pressure monitoring applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eContact us for a quotation, stock availability, delivery information, or replacement verification.\u003c\/strong\u003e Provide your complete model number and application requirements for technical assistance.\u003c\/p\u003e\n","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":68142125973686,"sku":"722B12TCD2FA","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/722B11TGA2FA-1_2d02e6b8-3728-4766-8e45-0d195dce3a93.jpg?v=1795504631","url":"https:\/\/www.plcsparehub.com\/es\/products\/722b12tcd2fa-mks-instruments-4-vcr-precision-pressure-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}