{"product_id":"626c11tde-mks-baratron-626c-precision-10-torr-vacuum-transducer","title":"626C11TDE MKS Baratron 626C Precision 10 Torr Vacuum Transducer","description":"\u003ch3\u003e\u003cstrong\u003eMKS Instruments 626C11TDE Baratron Absolute Pressure Transducer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e626C11TDE\u003c\/strong\u003e is an MKS Instruments Baratron® 626C Series non-heated capacitance diaphragm pressure transducer. It measures absolute pressure in vacuum systems operating within a 10 Torr full-scale range. Its room-temperature design suits applications that do not require a heated sensing assembly.\u003c\/p\u003e\n\u003cp\u003eThe transducer provides a stated accuracy of \u003cstrong\u003e±0.25% of reading\u003c\/strong\u003e and a linear \u003cstrong\u003e0–10 VDC analog output\u003c\/strong\u003e. It operates from a ±15 VDC supply and uses a nickel-alloy sensing construction, according to the supplied product information. These characteristics support precise vacuum monitoring in semiconductor equipment, laboratory systems, and industrial process installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1. Product Configuration at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Item\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e626C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-heated Baratron absolute capacitance manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Torr full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Option\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical connection code; confirm the exact interface before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical \/ Accuracy Option\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin D-sub electrical interface and stated ±0.25% of reading accuracy; verify the complete option definition against the MKS configuration record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant interface note:\u003c\/strong\u003e The supplied information describes the D connection in two different ways: 1\/2-inch Tube and NW16-KF. These are different mechanical interfaces and are not directly interchangeable. Confirm the actual flange or tube connection from the installed unit, equipment drawing, or manufacturer documentation before selecting a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2. Technical Data and Operating Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eBaratron®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e626C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e626C11TDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNon-heated absolute capacitance diaphragm pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e10 Torr absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Equivalent\u003c\/td\u003e\n\u003ctd\u003eApproximately 13.33 mbar \/ 1.33 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC, linear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e±15 VDC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-sub, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Materials\u003c\/td\u003e\n\u003ctd\u003eInconel® and Incoloy® nickel-based alloys, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overpressure\u003c\/td\u003e\n\u003ctd\u003e45 psia \/ approximately 310 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e3. How the 626C Measures Absolute Pressure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 626C uses a capacitance diaphragm measurement principle. Pressure applied to the sensing diaphragm causes a small mechanical displacement. The instrument detects the resulting capacitance change and converts it into a proportional electrical output.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute reference:\u003c\/strong\u003e The measurement references an internal vacuum rather than local atmospheric pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas-independent response:\u003c\/strong\u003e The sensing principle measures mechanical pressure rather than gas thermal conductivity or ionization characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous analog feedback:\u003c\/strong\u003e The 0–10 VDC output supports integration with compatible controllers and monitoring equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-heated construction:\u003c\/strong\u003e The sensor operates without a dedicated heated sensing chamber, making ambient-temperature compatibility an important selection factor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor process engineers, the key advantage is consistent pressure measurement without the gas-composition correction required by some alternative vacuum measurement technologies. However, process contamination and material compatibility still require careful evaluation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e4. Typical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication Area\u003c\/th\u003e\n\u003cth\u003eMeasurement Role\u003c\/th\u003e\n\u003cth\u003eEngineering Consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSemiconductor vacuum equipment\u003c\/td\u003e\n\u003ctd\u003eChamber pressure monitoring\u003c\/td\u003e\n\u003ctd\u003eCheck process cleanliness and the required pressure range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum coating systems\u003c\/td\u003e\n\u003ctd\u003ePressure feedback during vacuum processing\u003c\/td\u003e\n\u003ctd\u003eVerify the output scaling used by the control system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory vacuum systems\u003c\/td\u003e\n\u003ctd\u003eAbsolute pressure measurement\u003c\/td\u003e\n\u003ctd\u003eConfirm that the 10 Torr range matches the operating window.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial process chambers\u003c\/td\u003e\n\u003ctd\u003eVacuum status and process monitoring\u003c\/td\u003e\n\u003ctd\u003eEvaluate gas compatibility and possible contamination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum control assemblies\u003c\/td\u003e\n\u003ctd\u003eAnalog pressure feedback to controllers\u003c\/td\u003e\n\u003ctd\u003eCheck electrical loading and signal grounding.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e5. Electrical Integration and Commissioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect electrical integration is essential for accurate pressure feedback. Before connecting the transducer, verify the power supply, signal interface, and controller input configuration.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower verification:\u003c\/strong\u003e Confirm a ±15 VDC supply within the stated ±5% tolerance. Check both supply rails before connecting the instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector inspection:\u003c\/strong\u003e Verify the 15-pin D-sub connector and pin assignment against the applicable wiring documentation. Do not assume that visually similar connectors share the same pinout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal loading:\u003c\/strong\u003e Ensure the receiving input presents a load greater than 10 kΩ, as specified in the supplied data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput scaling:\u003c\/strong\u003e Configure the controller for a 0–10 VDC pressure signal and the correct 10 Torr full-scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical connection:\u003c\/strong\u003e Confirm whether the installed unit uses a Tube or NW16-KF connection before attaching the vacuum line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak inspection:\u003c\/strong\u003e Check seals and connection surfaces after installation. Perform the equipment-approved leak test before process operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReading validation:\u003c\/strong\u003e Compare the indicated pressure with a suitable reference instrument under stable vacuum conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not apply the maximum overpressure rating as a normal operating target. Pressure transients, mechanical shock, and contamination can affect sensor performance even when the electrical interface remains functional.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e6. Replacement Selection: What Must Match?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA replacement decision should consider the full instrument configuration rather than the model family alone. The following checks help prevent installation delays and signal compatibility problems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange compatibility:\u003c\/strong\u003e Select a 10 Torr absolute range when the process measurement window and required resolution support this range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy requirement:\u003c\/strong\u003e Compare the stated ±0.25% of reading specification with the process control tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Confirm the actual D-option mechanical interface. A Tube fitting and an NW16-KF flange require different installation hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical connector:\u003c\/strong\u003e Verify the 15-pin D-sub connector, pinout, and cable compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal requirements:\u003c\/strong\u003e Confirm 0–10 VDC output compatibility and the receiving input impedance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower requirements:\u003c\/strong\u003e Check the ±15 VDC supply and available current capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess compatibility:\u003c\/strong\u003e Review the wetted materials against the actual gases and cleaning procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen replacing an existing sensor, compare the complete nameplate and connector arrangement with the equipment documentation. A model from the same 626C family may still have a different range or connection configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e7. Maintenance and Troubleshooting Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003eChecks to Perform\u003c\/th\u003e\n\u003cth\u003eEngineering Response\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage does not respond to pressure changes\u003c\/td\u003e\n\u003ctd\u003ePower rails, connector wiring, and controller input\u003c\/td\u003e\n\u003ctd\u003eVerify the ±15 VDC supply and signal path before replacing the sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed pressure differs from a reference gauge\u003c\/td\u003e\n\u003ctd\u003eSignal scaling, reference conditions, and calibration history\u003c\/td\u003e\n\u003ctd\u003eCheck the 0–10 VDC conversion and compare readings under stable conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading fluctuates during operation\u003c\/td\u003e\n\u003ctd\u003eElectrical noise, grounding, pressure instability, and cable condition\u003c\/td\u003e\n\u003ctd\u003eSeparate process fluctuations from signal interference through independent measurements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum performance changes after maintenance\u003c\/td\u003e\n\u003ctd\u003eConnection seals, contamination, and installation condition\u003c\/td\u003e\n\u003ctd\u003eInspect the vacuum connection and perform the approved leak test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eKeep a record of calibration results, operating conditions, and maintenance history. These records help identify gradual measurement drift and distinguish instrument problems from vacuum-system faults. Avoid opening or modifying the sensing assembly without an approved service procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e8. Warranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e MKS Instruments 626C11TDE Baratron 626C Series pressure transducer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Options:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Confirmation:\u003c\/strong\u003e Please provide the complete model number and confirm the mechanical connection before purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Support:\u003c\/strong\u003e Connector, pinout, and pressure-range information can be checked against the equipment requirements before order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e9. Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why can a 10 Torr sensor show a different pressure from a Pirani gauge in the same vacuum line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe two instruments use different measurement principles. A capacitance manometer measures mechanical pressure, while a Pirani gauge responds to gas thermal conductivity. Gas composition and calibration conditions can therefore produce different readings. Use a suitable reference standard when evaluating measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should be checked if the transducer output is correct at the connector but incorrect on the HMI?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the analog input channel configuration, input impedance, signal common, grounding, and engineering-unit conversion. Confirm that the controller maps 0–10 VDC to the intended 0–10 Torr range. This check can prevent unnecessary sensor replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is a 10 Torr full-scale model always the best choice for a vacuum process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. The expected operating pressure, process transients, required control margin, and measurement tolerance should guide range selection. A range that is too high may reduce useful signal utilization, while a range that is too low may expose the instrument to unsuitable pressure conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can maintenance teams identify an incorrect replacement connection before installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the installed flange or tube outside diameter, sealing method, and equipment drawing with the replacement specification. Do not identify the connection from the single letter D alone. The supplied configuration descriptions conflict between 1\/2-inch Tube and NW16-KF, so physical verification is essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What records are most useful when sourcing a replacement for an older vacuum instrument?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKeep the complete part number, equipment model, nameplate photograph, connector pinout, mounting dimensions, controller scaling, and process-gas information. These records help suppliers distinguish between similar models and reduce the risk of ordering a unit with an incompatible interface.\u003c\/p\u003e","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":68142290206902,"sku":"626C11TDE","price":103.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/626B13TDE-1_893be77c-9e14-412c-bed1-0295a4e341b4.jpg?v=1795504573","url":"https:\/\/www.plcsparehub.com\/es\/products\/626c11tde-mks-baratron-626c-precision-10-torr-vacuum-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}