{"product_id":"626bretaf-mks-instruments-capacitance-diaphragm-pressure-transducer","title":"626BRETAF MKS Instruments Capacitance Diaphragm Pressure Transducer","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | MKS Baratron 626B Pressure Measurement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677a8;\"\u003eMKS Instruments 626BRETAF\u003c\/span\u003e\u003c\/strong\u003e is a precision capacitance diaphragm pressure transducer from the \u003cstrong\u003eBaratron® 626B Series\u003c\/strong\u003e. It measures absolute pressure through a capacitive sensing structure. Its measurement principle operates independently of gas composition.\u003c\/p\u003e\n\u003cp\u003eThis configuration provides a \u003cstrong\u003e0.25 Torr full-scale range\u003c\/strong\u003e and \u003cstrong\u003e±0.50% of reading accuracy\u003c\/strong\u003e. It uses a 1\/2-inch tubulation connection and a 15-pin male D-subminiature electrical connector.\u003c\/p\u003e\n\u003cp\u003eThe sensor delivers a linear \u003cstrong\u003e0–10 VDC analog output\u003c\/strong\u003e for compatible pressure monitoring and control systems. Its Inconel® and Incoloy® wetted materials support demanding vacuum process environments.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e626BRETAF\u003c\/strong\u003e suits vacuum equipment, semiconductor processing systems, and precision pressure monitoring applications. Its fast response and low-pressure measurement capability support process control and equipment diagnostics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Model Identification and Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe model code identifies the sensor family, measurement range, connection configuration, and accuracy grade. The following breakdown follows the supplied 626B configuration information.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Meaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e626B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eBaratron® 626B ambient-temperature absolute pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRET\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e0.25 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFitting Configuration\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch (12.7 mm) OD tubulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy Code\u003c\/td\u003e\n\u003ctd\u003e±0.50% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Model:\u003c\/strong\u003e \u003cspan style=\"color: #1677a8;\"\u003e\u003cstrong\u003e626BRETAF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Summary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Family:\u003c\/strong\u003e Baratron® capacitance diaphragm pressure measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Reference:\u003c\/strong\u003e Absolute pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e 0.25 Torr full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Connection:\u003c\/strong\u003e 1\/2-inch OD tubulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Grade:\u003c\/strong\u003e ±0.50% of reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e 15-pin male D-sub connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis model belongs to the ambient-temperature 626B configuration. Do not confuse it with heated Baratron transducers designed for elevated-temperature operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Core Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e626BRETAF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eBaratron® 626B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCapacitance Diaphragm Gauge \/ Absolute Pressure Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eCapacitance diaphragm sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Reference\u003c\/td\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.25 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.50% of reading\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable Measurement Range\u003c\/td\u003e\n\u003ctd\u003e1 × 10⁻⁴ of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Minimum Pressure for Reading\u003c\/td\u003e\n\u003ctd\u003e1 × 10⁻⁴ Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Minimum Pressure for Control\u003c\/td\u003e\n\u003ctd\u003e1 × 10⁻³ Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e0 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e≥10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e±15 VDC (±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin male D-subminiature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch (12.7 mm) OD tubulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Materials\u003c\/td\u003e\n\u003ctd\u003eInconel® 600 and Incoloy®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e15°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure Limit\u003c\/td\u003e\n\u003ctd\u003e45 psia (310 kPa), without damage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up Time\u003c\/td\u003e\n\u003ctd\u003e15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Constant\u003c\/td\u003e\n\u003ctd\u003eLess than 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Volume, Px Side\u003c\/td\u003e\n\u003ctd\u003e6.3 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Measurement Principle and Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBaratron® 626B\u003c\/strong\u003e uses a thin diaphragm as its pressure-sensitive element. Pressure changes cause diaphragm displacement. The resulting capacitance variation produces an electrical measurement signal.\u003c\/p\u003e\n\u003cp\u003eUnlike thermal conductivity vacuum gauges, capacitance diaphragm technology does not depend on the thermal properties of the measured gas. This characteristic supports pressure measurement across different process gas compositions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Pressure Measurement:\u003c\/strong\u003e Measures pressure relative to an internal reference vacuum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Independence:\u003c\/strong\u003e The measurement principle does not rely on gas thermal conductivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Output:\u003c\/strong\u003e Provides a 0–10 VDC signal proportional to pressure across the specified range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Response:\u003c\/strong\u003e Time constant remains below 20 milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Pressure Capability:\u003c\/strong\u003e Supports readings down to the specified minimum pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy Interpretation:\u003c\/strong\u003e The ±0.50% reading specification includes non-linearity, hysteresis, and non-repeatability. This accuracy code applies to the specified 0.10 Torr and 0.25 Torr ranges.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Electrical Interface and Signal Conditioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e626BRETAF\u003c\/strong\u003e requires a bipolar power supply and provides a single-ended positive analog output. Proper grounding and shielding are essential for stable low-pressure measurements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRequirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive Supply\u003c\/td\u003e\n\u003ctd\u003e+15 VDC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNegative Supply\u003c\/td\u003e\n\u003ctd\u003e-15 VDC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Output Load\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin male D-subminiature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Shielding\u003c\/td\u003e\n\u003ctd\u003eOverall metal-braided shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Grounding\u003c\/td\u003e\n\u003ctd\u003eGround at both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Recommendation:\u003c\/strong\u003e Use a properly shielded cable with an overall metal braid. Ground the shield at both ends according to the manufacturer's installation instructions.\u003c\/p\u003e\n\u003cp\u003eKeep signal wiring away from high-current switching conductors where practical. Verify the controller input impedance before connecting the analog output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The supplied specifications do not establish the individual 15-pin connector pin assignments. Obtain the correct MKS wiring diagram before terminating the cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Temperature Characteristics and Overpressure Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ambient-temperature configuration operates within a specified range of \u003cstrong\u003e15°C to 40°C\u003c\/strong\u003e. Temperature coefficients determine the expected measurement variation as ambient conditions change.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e15°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.005% F.S.\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.04% of reading\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overpressure\u003c\/td\u003e\n\u003ctd\u003e45 psia (310 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up Period\u003c\/td\u003e\n\u003ctd\u003e15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOverpressure Consideration:\u003c\/strong\u003e The 45 psia limit specifies the maximum pressure without damage. It does not represent the normal measurement range.\u003c\/p\u003e\n\u003cp\u003eAvoid sudden pressure surges during pump-down and process venting. Use suitable isolation and pressure-control arrangements when the system can experience abnormal pressure conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Process Connection and Wetted Materials\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe model suffix identifies a \u003cstrong\u003e1\/2-inch OD tubulation\u003c\/strong\u003e connection. This configuration supports compatible vacuum tubing and process connection arrangements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitting Code\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eOD tubulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Outside Diameter\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (1\/2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Material\u003c\/td\u003e\n\u003ctd\u003eInconel® 600 and Incoloy®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative Fitting Materials\u003c\/td\u003e\n\u003ctd\u003eSome optional fittings use 300-series stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-Side Internal Volume\u003c\/td\u003e\n\u003ctd\u003e6.3 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Selection:\u003c\/strong\u003e Inconel and Incoloy provide corrosion-resistant metallic construction. Confirm chemical compatibility with the actual process gas and cleaning chemicals before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect installation helps preserve measurement accuracy and signal stability. Follow these engineering checks before introducing the sensor into the vacuum system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Connection:\u003c\/strong\u003e Confirm the 1\/2-inch OD tubulation matches the process tubing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Environment:\u003c\/strong\u003e Maintain ambient temperature between 15°C and 40°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Provide stable +15 VDC and -15 VDC rails within ±5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Connection:\u003c\/strong\u003e Connect the 0–10 VDC output to a compatible analog input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e Maintain a receiving load of at least 10 kΩ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Use an overall metal-braided shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ground the cable shield at both ends as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-Up:\u003c\/strong\u003e Allow at least 15 minutes before evaluating measurement performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Verification:\u003c\/strong\u003e Compare the sensor output with a suitable reference instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Tip:\u003c\/strong\u003e Do not evaluate the final zero reading immediately after power-up. Allow the specified warm-up period and confirm stable ambient conditions first.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Maintenance and Measurement Stability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRoutine inspection helps identify installation-related measurement errors before they affect process control. Focus on the electrical supply, cable shielding, process connection, and operating environment.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInspection Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Action\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eMeasure both positive and negative supply rails.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003eVerify output voltage against the applied reference pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Cable\u003c\/td\u003e\n\u003ctd\u003eInspect braid continuity and grounding at both ends.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Tubing\u003c\/td\u003e\n\u003ctd\u003eCheck connection integrity and possible leakage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eConfirm operation within the specified ambient range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up\u003c\/td\u003e\n\u003ctd\u003eAllow 15 minutes after power-up before measurement evaluation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Stability\u003c\/td\u003e\n\u003ctd\u003eCompare readings under repeatable reference conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Recommendation:\u003c\/strong\u003e Avoid unnecessary mechanical handling of the pressure-sensitive assembly. Investigate zero shifts before adjusting system scaling or replacing the controller input module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | System Compatibility and Application Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMKS 626BRETAF\u003c\/strong\u003e supports vacuum measurement systems that accept bipolar power and a 0–10 VDC analog signal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Controllers:\u003c\/strong\u003e Connect to compatible voltage-input pressure controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Systems:\u003c\/strong\u003e Use an analog input channel with a suitable 0–10 VDC range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Systems:\u003c\/strong\u003e Integrate through a compatible voltage signal conditioning module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e Monitor pressure in compatible vacuum process chambers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Deposition:\u003c\/strong\u003e Support pressure monitoring in coating and thin-film equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch Systems:\u003c\/strong\u003e Provide absolute pressure feedback for laboratory vacuum equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eScaling Reference:\u003c\/strong\u003e The 0–10 VDC output corresponds to the specified 0–0.25 Torr full-scale range. Confirm the controller's scaling configuration before using the signal for closed-loop control.\u003c\/p\u003e\n\u003cp\u003eDo not connect the voltage output directly to a 4–20 mA input without a suitable signal conversion interface. Verify connector pinout and power requirements before integrating the sensor into an existing system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Compliance and Environmental Directives\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003ctd\u003eEMC Directive 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2002\/95\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eConfirm the applicable documentation and compliance requirements for the equipment installation date and destination market.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Typical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Manufacturing:\u003c\/strong\u003e Monitor absolute pressure in vacuum process equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin-Film Deposition:\u003c\/strong\u003e Provide pressure feedback for deposition chamber control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Coating:\u003c\/strong\u003e Monitor pressure conditions during coating operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaboratory Vacuum Systems:\u003c\/strong\u003e Support precise pressure measurement and experimental control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Vacuum Equipment:\u003c\/strong\u003e Provide analog pressure feedback to automation controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Development:\u003c\/strong\u003e Monitor low-pressure conditions in controlled experimental environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e12 | Selection and Replacement Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineers should verify the complete configuration before selecting this model for a new installation or replacement project.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Verification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e626BRETAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0.25 Torr full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.50% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Reference\u003c\/td\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitting\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch OD tubulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin male D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e±15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e15°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Warning:\u003c\/strong\u003e Do not select a replacement based only on the 626B series designation. Verify the full suffix, pressure range, fitting, accuracy code, connector, and supply requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e13 | Packaging, Warranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e MKS Instruments 626BRETAF Baratron® Pressure Transducer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e 0.25 Torr, 1\/2-inch OD tubulation, 15-pin male D-sub.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Suitable packaging for industrial precision instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Documentation:\u003c\/strong\u003e Supplied according to the confirmed order configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e FedEx, UPS, and DHL international delivery services.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Condition:\u003c\/strong\u003e New and original factory-supplied equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Note:\u003c\/strong\u003e Confirm the exact suffix and required accessories before ordering. Cables, controllers, and additional vacuum fittings require separate confirmation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e14 | Technical FAQ and Engineering Selection Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why should engineers choose a capacitance diaphragm gauge instead of a thermal conductivity vacuum gauge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA capacitance diaphragm gauge measures pressure through mechanical diaphragm displacement. Its measurement principle does not depend on the thermal conductivity of the process gas. This makes it suitable for applications where gas composition changes during processing. Engineers should still consider pressure range, accuracy, and operating conditions when selecting the technology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 626BRETAF measure pressure when the process gas changes from nitrogen to argon?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The capacitance measurement principle does not require gas-specific thermal conductivity correction. However, process compatibility and the pressure connection must remain suitable for the actual gas. Check material compatibility when handling reactive or corrosive gases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the practical difference between pressure measurement and pressure control at very low vacuum levels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasurement indicates the pressure available for monitoring. Closed-loop control also depends on signal stability, controller resolution, system response, and process dynamics. The suggested minimum pressure is 1 × 10⁻⁴ Torr for reading and 1 × 10⁻³ Torr for control. Engineers should use these limits when defining control strategies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why might a PLC display an unstable pressure value even when the transducer operates correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the analog input impedance, grounding arrangement, and cable shielding first. Electrical noise can affect low-level measurement signals. Also verify the bipolar supply rails and controller scaling. A stable pressure reference helps distinguish electrical interference from actual process fluctuations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should be considered when replacing a 626B transducer with a different pressure range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the full-scale range, output scaling, accuracy specification, fitting, and electrical interface. A different range changes the pressure-to-voltage relationship. The controller may require new scaling parameters. Confirm the mechanical connection and calibration requirements before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePrecision Vacuum Measurement for Critical Processes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677a8;\"\u003eMKS Instruments 626BRETAF\u003c\/span\u003e\u003c\/strong\u003e combines Baratron® capacitance diaphragm technology with a 0.25 Torr measurement range and ±0.50% of reading accuracy.\u003c\/p\u003e\n\u003cp\u003eIts 0–10 VDC output, 15-pin D-sub interface, and 1\/2-inch tubulation support integration into compatible vacuum measurement systems. The configuration suits applications that require gas-independent absolute pressure monitoring and fast measurement response.\u003c\/p\u003e\n\u003cp\u003eContact us for a quotation, availability, technical documentation, or replacement verification. Provide your existing model number and system requirements for configuration assistance.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/626B.png?v=1793609967\" alt=\"\"\u003e\u003c\/p\u003e","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":68141788332214,"sku":"626BRETAF","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/626B13TBE-3.jpg?v=1793610114","url":"https:\/\/www.plcsparehub.com\/es\/products\/626bretaf-mks-instruments-capacitance-diaphragm-pressure-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}