{"title":"Renishaw","description":"\u003cp\u003eRenishaw is a global benchmark in high-precision metrology, position feedback, and industrial process control, engineered to achieve sub-micron accuracy in demanding CNC machining and motion systems. Our technical inventory covers the full spectrum of Renishaw automation components, including high-resolution optical and magnetic linear\/rotary encoders (TONiC™, RESOLUTE™, and QUANTiC™ series) supporting BiSS-C, Panasonic, and Siemens DRIVE-CLiQ serial protocols. For automated workpiece setup and tool setting, we supply robust machine tool probing systems featuring optical (OMP\/OTS) and frequency-hopping radio (RMP\/RTS) transmission alongside RMI-Q interfaces. We also stock CMM motorized indexing heads (PH10 series), kinematic touch-trigger probes (TP20\/TP200), and replacement styli. Built for zero-backlash kinematics, high-speed scanning, and harsh coolant-rich environments, these genuine Renishaw spare parts enable rapid calibration, reduced scrap rates, and minimal machine tool downtime across aerospace, semiconductor, and precision manufacturing lines.\u003c\/p\u003e","products":[{"product_id":"renishaw-rgh22b30l00a-rg2-1vpp-incremental-encoder-read-head","title":"Renishaw RGH22B30L00A RG2 1Vpp Incremental Encoder Read Head","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRenishaw RGH22B30L00A\u003c\/span\u003e\u003c\/strong\u003e is a non-contact incremental optical readhead from the \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRG2 series\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt reads position information from a compatible linear scale without mechanical contact. Its optical sensing system supports accurate motion feedback in precision positioning applications.\u003c\/p\u003e\n\u003cp\u003eThis configuration provides \u003cstrong\u003e1 Vpp differential analog output\u003c\/strong\u003e, single-limit sensing, and a 3-meter cable. It connects to compatible motion controllers and encoder interface systems through a 15-pin D-type connector.\u003c\/p\u003e\n\u003cp\u003eThe readhead typically operates with the \u003cstrong\u003eRenishaw RGS20-S gold-plated steel scale\u003c\/strong\u003e, which features a 20 µm scale pitch. Engineers can use this combination in semiconductor equipment, precision machine tools, electronic assembly systems, and automated inspection equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGH22B30L00A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRG2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIncremental Optical Linear Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Technology\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e1 Vpp differential analog signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit Detection\u003c\/td\u003e\n\u003ctd\u003eSingle-limit sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRGS20-S gold-plated steel scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e20 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 10 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type analog connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard alarm-line configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Bracket\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × L × W)\u003c\/td\u003e\n\u003ctd\u003e14.8 × 36.0 × 13.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code identifies the readhead configuration and electrical connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGH22:\u003c\/strong\u003e RG2 optical readhead with integrated signal processing and reference functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB:\u003c\/strong\u003e 1 Vpp differential analog output with single-limit sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30:\u003c\/strong\u003e 3.0-meter cable configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL:\u003c\/strong\u003e 15-pin D-type connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Standard alarm-line configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Readhead supplied without a mounting bracket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Note:\u003c\/strong\u003e Verify the complete suffix before ordering. Connector, cable, limit sensing, and mounting arrangements affect system compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Principle:\u003c\/strong\u003e Optical incremental position detection provides non-contact motion feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Output:\u003c\/strong\u003e Differential 1 Vpp analog signals support compatible encoder interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotion Capability:\u003c\/strong\u003e Maximum operating speed reaches 10 m\/s under suitable system conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition Resolution:\u003c\/strong\u003e The final resolution depends on the receiving controller's interpolation electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Pitch:\u003c\/strong\u003e The recommended RGS20-S scale uses a 20 µm graduation pitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Function:\u003c\/strong\u003e Integrated reference sensing supports repeatable machine-axis referencing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit Function:\u003c\/strong\u003e Single-limit sensing provides an additional axis-position detection function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The 20 µm scale pitch does not represent the final machine positioning resolution. Controller interpolation determines the effective digital resolution.\u003c\/p\u003e\n\u003cp\u003eSpecific linearity, signal frequency limits, interpolation accuracy, and electrical noise immunity require confirmation against the applicable Renishaw technical documentation. Do not treat the maximum speed as a guaranteed operating speed under every controller configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the scale:\u003c\/strong\u003e Check the RGS20-S surface for contamination, scratches, and installation damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the mounting surface:\u003c\/strong\u003e Ensure the machine mounting face remains clean and stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the readhead:\u003c\/strong\u003e Secure the RGH22B30L00A using a compatible mounting arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the alignment:\u003c\/strong\u003e Follow Renishaw installation specifications for readhead height, pitch, roll, and yaw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the cable:\u003c\/strong\u003e Keep the 3-meter cable away from motor power lines and high-current switching circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the interface:\u003c\/strong\u003e Match the 15-pin D-type connector and signal assignments with the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the supply:\u003c\/strong\u003e Confirm a stable 5 V ±5% power supply before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This model does not include a mounting bracket. Confirm the required mounting hardware before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe integrated alignment LED simplifies initial setup and optical signal adjustment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the LED indication during initial readhead alignment.\u003c\/li\u003e\n\u003cli\u003eVerify the 1 Vpp differential output with compatible measurement equipment.\u003c\/li\u003e\n\u003cli\u003eConfirm reference and single-limit signals during axis commissioning.\u003c\/li\u003e\n\u003cli\u003eMove the axis slowly and inspect signal stability across the travel range.\u003c\/li\u003e\n\u003cli\u003eCheck connector engagement and cable routing during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003eClean the optical area using an approved method when contamination affects signal quality.\u003c\/li\u003e\n\u003cli\u003eInvestigate intermittent feedback before adjusting controller interpolation settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStable optical alignment helps prevent position feedback errors. Proper cable separation also reduces electrical interference risks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Application Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility Considerations\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Scale\u003c\/td\u003e\n\u003ctd\u003eRGS20-S gold-plated steel scale with 20 µm pitch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Controller\u003c\/td\u003e\n\u003ctd\u003eRequires a compatible 1 Vpp differential encoder input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eProvides regulated 5 V ±5% power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eRequires a matching 15-pin D-type connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit Input\u003c\/td\u003e\n\u003ctd\u003eController must support the specified single-limit sensing arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003eRequires a suitable mounting bracket or approved mounting solution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor wafer positioning and precision handling equipment.\u003c\/li\u003e\n\u003cli\u003eCNC machine tools and high-accuracy linear positioning axes.\u003c\/li\u003e\n\u003cli\u003eElectronic component placement and assembly machinery.\u003c\/li\u003e\n\u003cli\u003eAutomated optical inspection and measurement systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial motion stages requiring incremental position feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP50 under the specified protection classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Environment:\u003c\/strong\u003e Use in clean, controlled industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContamination Control:\u003c\/strong\u003e Protect the optical sensing area from dust, oil, and machining debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Protection:\u003c\/strong\u003e Use appropriate cable routing and grounding practices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIP50 does not provide protection against water ingress. Avoid direct exposure to coolant, washdown, and conductive contamination.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe available configuration information does not establish specific certifications for \u003cstrong\u003eRGH22B30L00A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eContact us for applicable manufacturer documentation, product identification details, and compliance information. Verify installation requirements against the complete machine-system standards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Renishaw RGH22B30L00A RG2 optical linear encoder readhead.\u003c\/li\u003e\n\u003cli\u003eIntegrated 3.0-meter cable.\u003c\/li\u003e\n\u003cli\u003e15-pin D-type connector configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The mounting bracket and RGS20-S scale are not included unless the order explicitly specifies them.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the RGH22B30L00A connect directly to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot to every standard PLC input. This readhead provides 1 Vpp differential analog signals. The PLC or motion controller needs a compatible encoder interface or signal conversion module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does a 20 µm scale pitch mean the positioning resolution is 20 µm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The scale pitch defines the optical graduation spacing. The receiving interpolation electronics determine the final digital resolution. Check the controller's interpolation ratio before calculating axis positioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the position signal becomes unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with optical alignment and scale cleanliness. Then inspect the 5 V supply, connector contacts, cable routing, and differential signal quality. Check motor drive interference if the fault appears during acceleration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this readhead operate without the RGS20-S scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires a compatible optical scale. The RGS20-S is the specified matching scale in this configuration. Confirm scale compatibility before replacing an existing encoder assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should buyers distinguish this model from other RG2 readheads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete ordering code rather than the RGH22 family designation alone. This model specifies 1 Vpp output, single-limit sensing, a 3-meter cable, and a 15-pin D-type connector. It also excludes the mounting bracket.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22.png?v=1795576438\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155192508598,"sku":"RGH22B30L00A","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22B30L00A-3.jpg?v=1795576415"},{"product_id":"renishaw-rgh22b50l00a-linear-optical-encoder-readhead","title":"Renishaw RGH22B50L00A Linear Optical Encoder Readhead","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #e87516;\"\u003eRenishaw RGH22B50L00A\u003c\/strong\u003e is a non-contact optical linear encoder readhead. It belongs to the \u003cstrong style=\"color: #e87516;\"\u003eRGH22 series\u003c\/strong\u003e within the RG2 incremental encoder system.\u003c\/p\u003e\n\u003cp\u003eThis readhead provides \u003cstrong\u003e1 Vpp differential analogue output\u003c\/strong\u003e for precision linear position feedback. It operates with the \u003cstrong\u003e20 µm pitch RGS20-S reflective steel scale\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe RGH22B configuration includes a single limit sensor and an integrated reference mark sensor. Its open optical design supports non-contact position measurement without mechanical contact with the scale.\u003c\/p\u003e\n\u003cp\u003eThe integrated set-up LED helps engineers check installation alignment. Internal signal interpolation supports stable position feedback in motion control applications.\u003c\/p\u003e\n\u003cp\u003eThe 5 m cable and 15-way D-type connector simplify integration with compatible controller interfaces. The standard 00A configuration provides the specified factory connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical measurement:\u003c\/strong\u003e Non-contact incremental linear position detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal output:\u003c\/strong\u003e 1 Vpp differential analogue signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale compatibility:\u003c\/strong\u003e 20 µm pitch RGS20-S reflective steel scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit detection:\u003c\/strong\u003e Integrated single limit sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference positioning:\u003c\/strong\u003e Integrated reference mark detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation support:\u003c\/strong\u003e Built-in multicolour set-up LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable assembly:\u003c\/strong\u003e 5 m, 12-core, double-shielded cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 15-way D-type plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGH22B50L00A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eRGH22 \/ RG2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOpen Optical Linear Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical incremental measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e1 Vpp differential analogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRGS20-S reflective steel tape scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e20 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle limit sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Mark\u003c\/td\u003e\n\u003ctd\u003eIntegrated reference mark sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e12-core, double-shielded, high-flexibility cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e4.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e15-way D-type plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e00A Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA, unterminated readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Termination Current\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 mA with 120 Ω analogue termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analogue Readhead Speed\u003c\/td\u003e\n\u003ctd\u003e4 m\/s at −3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide Height\u003c\/td\u003e\n\u003ctd\u003e0.8 ±0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Acceleration\u003c\/td\u003e\n\u003ctd\u003e500 m\/s², three axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e100 m\/s² maximum, 55 Hz to 2000 Hz, three axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating Shock\u003c\/td\u003e\n\u003ctd\u003e1000 m\/s², 6 ms, half-sine, three axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Weight\u003c\/td\u003e\n\u003ctd\u003e45 g, excluding cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e The scale determines the available measuring length. RGS20-S supports lengths up to 50 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal period:\u003c\/strong\u003e The analogue signal corresponds to the 20 µm scale pitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum speed:\u003c\/strong\u003e The RGH22A\/B analogue range supports up to 4 m\/s at −3 dB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale linearity:\u003c\/strong\u003e RGS20-S provides ±3 µm\/m scale linearity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e The analogue output does not specify one fixed digital resolution. The receiving controller determines interpolation resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e The manufacturer specifies 1 Vpp differential output rather than a separate sensitivity value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency response:\u003c\/strong\u003e The manufacturer specifies maximum analogue speed at −3 dB. Confirm controller bandwidth before system design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect mechanical alignment directly affects signal quality and measurement stability.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the machine uses the compatible \u003cstrong\u003eRGS20-S 20 µm scale\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eClean the mounting surface before installing the scale.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified scale alignment with the machine travel axis.\u003c\/li\u003e\n\u003cli\u003eMount the readhead using the designated fixing holes.\u003c\/li\u003e\n\u003cli\u003eSet the readhead ride height to \u003cstrong\u003e0.8 ±0.1 mm\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCheck the pitch and roll alignment against the installation drawing.\u003c\/li\u003e\n\u003cli\u003ePosition the reference mark actuator correctly along the measuring axis.\u003c\/li\u003e\n\u003cli\u003ePosition the single limit actuator within its specified sensing area.\u003c\/li\u003e\n\u003cli\u003eUse the integrated set-up LED to check optical alignment.\u003c\/li\u003e\n\u003cli\u003eConnect the 15-way D-type plug to the compatible receiving interface.\u003c\/li\u003e\n\u003cli\u003eVerify the 5 V DC supply before enabling machine movement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eMaintain the cable bend radius during installation. Follow the manufacturer's dynamic and static bend requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower verification:\u003c\/strong\u003e Check the 5 V DC supply and voltage stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal verification:\u003c\/strong\u003e Measure both differential analogue signal pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal balance:\u003c\/strong\u003e Check signal amplitude and waveform quality during axis movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference testing:\u003c\/strong\u003e Confirm repeatable reference mark detection in the intended travel direction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit testing:\u003c\/strong\u003e Verify the single limit output with its actuator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlignment inspection:\u003c\/strong\u003e Check the set-up LED and specified ride height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding inspection:\u003c\/strong\u003e Verify the inner and outer shield connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical inspection:\u003c\/strong\u003e Check scale adhesion, contamination and cable condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor electrical noise control, follow Renishaw's grounding arrangement. Connect the outer shield to machine earth. Connect the inner shield to 0 V. Keep both shields electrically isolated.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRGH22B50L00A\u003c\/strong\u003e requires a compatible RGS20-S optical scale. The receiving controller must support 1 Vpp differential analogue inputs.\u003c\/p\u003e\n\u003cp\u003eEngineers should verify the connector pinout, supply voltage and signal termination before installation.\u003c\/p\u003e\n\u003cp\u003eTypical application areas include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCoordinate measuring and dimensional inspection machines.\u003c\/li\u003e\n\u003cli\u003ePrecision linear positioning systems.\u003c\/li\u003e\n\u003cli\u003eSemiconductor and electronics manufacturing equipment.\u003c\/li\u003e\n\u003cli\u003eFlat panel display production equipment.\u003c\/li\u003e\n\u003cli\u003eAutomated inspection and measurement systems.\u003c\/li\u003e\n\u003cli\u003eLinear motor positioning platforms.\u003c\/li\u003e\n\u003cli\u003eElectronics assembly and testing equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility note:\u003c\/strong\u003e Do not treat digital RS422 RGH22 variants as direct electrical replacements. Their output interfaces differ from the RGH22B analogue configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Resistance and Signal Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGH22 readhead uses a double-shielded cable to support signal integrity. Its open optical design requires suitable protection from external contamination.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress protection:\u003c\/strong\u003e IP50 protects against dust ingress at the specified test level. It does not provide water protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical noise:\u003c\/strong\u003e Correct grounding and shield separation help reduce interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e The readhead supports the specified operating vibration conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical shock:\u003c\/strong\u003e The datasheet specifies a non-operating shock limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Maintain the readhead within its rated operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGH22 technical datasheet specifies electrical, environmental and mechanical operating limits.\u003c\/p\u003e\n\u003cp\u003eIt also references a 5 V DC supply compliant with SELV requirements under IEC BS EN 60950-1.\u003c\/p\u003e\n\u003cp\u003eSpecific product certification documents are not confirmed by the available model information. Please request applicable declarations and certificates when required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Renishaw RGH22B50L00A optical encoder readhead.\u003c\/li\u003e\n\u003cli\u003e1 × Integrated 5 m double-shielded cable.\u003c\/li\u003e\n\u003cli\u003e1 × 15-way D-type connector.\u003c\/li\u003e\n\u003cli\u003eProduct identification and applicable documentation, subject to supply scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The RGS20-S scale and mounting accessories are separate items unless the quotation explicitly includes them. Confirm the delivery scope before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which scale works with the RGH22B50L00A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe compatible scale is the Renishaw RGS20-S reflective steel tape scale. It uses a 20 µm pitch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the RGH22B50L00A provide digital RS422 output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This model provides 1 Vpp differential analogue output. Select a digital RGH22 variant for RS422 signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the readhead operate without an RGS20-S scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The optical readhead requires a compatible scale for incremental position measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why does the analogue signal become unstable after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst inspect ride height, optical alignment and scale cleanliness. Then check the 5 V supply, grounding and cable shielding. Incorrect termination can also affect waveform quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should engineers check when replacing an existing RGH22 readhead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete part number, output type, cable length and connector. Also verify the limit configuration and reference mark operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Can a controller accept the RGH22B output directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly if its input supports compatible 1 Vpp differential analogue signals. Check input impedance, bandwidth and signal conditioning requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: Does the 20 µm scale pitch represent the final positioning resolution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The controller determines the final interpolated resolution. Check its interpolation capability and input specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Does the 5 m cable support long-distance signal transmission?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated cable measures 5 m. The manufacturer permits longer extension arrangements under specified shielding and wiring conditions. Consult the RGH22 installation documentation before extending the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: What information should buyers confirm before ordering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the complete model number, connector, cable length and scale compatibility. Also check the controller input type and required mounting accessories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: Is the RGS20-S scale included with this readhead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. The readhead and scale form separate system components. Confirm the quotation and packing list before purchase.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155195031734,"sku":"RGH22B50L00A","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22B50L00A-3.jpg?v=1795576581"},{"product_id":"q4bcy30d10a-renishaw-quantic-incremental-optical-encoder-readhead","title":"Q4BCY30D10A Renishaw QUANTiC Incremental Optical Encoder Readhead","description":"\u003ch3\u003e\u003cb\u003e01 | Product Identity – Optical Feedback Technology\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #167a65;\"\u003eRenishaw Q4BCY30D10A\u003c\/span\u003e\u003c\/strong\u003e is a QUANTiC™ incremental optical encoder readhead for precision linear motion systems. It reads an optical scale and generates incremental position feedback for motion controllers. Its 40 µm scale pitch supports accurate position measurement in industrial automation equipment. The readhead integrates optical signal processing and automatic signal adjustment functions. Its compact design supports machine integration where positioning accuracy and installation flexibility matter. Key identification:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Renishaw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eQ4BCY30D10A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e QUANTiC™\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Incremental Optical Encoder Readhead\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Configuration:\u003c\/strong\u003e Linear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Pitch:\u003c\/strong\u003e 40 µm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Resolution:\u003c\/strong\u003e 0.1 µm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Configuration:\u003c\/strong\u003e Customer-selectable reference mark and limit sensor arrangement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e02 | Configuration Breakdown – Decode Every Suffix\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete order code identifies the readhead configuration and electrical interface. The following table follows the supplied model-code interpretation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eEngineering Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQ4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eQUANTiC™ series, 40 µm scale pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eLinear encoder configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReadhead Version\u003c\/td\u003e\n\u003ctd\u003eStandard readhead with integrated setup LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µm digital resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type connector (DB15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReference \/ Limit Configuration\u003c\/td\u003e\n\u003ctd\u003eCustomer-selectable reference mark and dual-limit sensor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cblockquote\u003eQ4 → 40 µm QUANTiC™ platform B → Linear measurement system C → Standard readhead with setup LED Y → 0.1 µm digital resolution 30 → 3.0 m cable D → 15-pin D-type connector 10 → 10 MHz clock frequency A → Reference and limit sensor configuration\u003c\/blockquote\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Selection Note:\u003c\/strong\u003e Confirm the complete suffix against the official Renishaw ordering documentation. Verify the required reference and limit functions before placing an order.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Optical Performance – Position Feedback Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Technology\u003c\/td\u003e\n\u003ctd\u003eIncremental optical sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Direction\u003c\/td\u003e\n\u003ctd\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µm (100 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Series Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 24 m\/s, subject to resolution and clock configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Height Tolerance\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngular Installation Tolerance\u003c\/td\u003e\n\u003ctd\u003e±0.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Adjustment\u003c\/td\u003e\n\u003ctd\u003eAGC, ABC and AOC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup Indicator\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Interpretation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 nm Resolution:\u003c\/strong\u003e Provides fine digital position increments for precision motion feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz Clock:\u003c\/strong\u003e Defines an important part of the digital interface and maximum speed capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 m\/s Series Capability:\u003c\/strong\u003e Represents the stated QUANTiC family maximum, not a guaranteed speed at every resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Tolerance:\u003c\/strong\u003e Reduces sensitivity to minor mounting variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conditioning:\u003c\/strong\u003e Helps maintain stable optical feedback during normal operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Resolution represents the digital measurement increment. It does not independently define system accuracy, repeatability or measurement uncertainty.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Intelligent Signal Control – AGC, ABC and AOC\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe QUANTiC™ readhead integrates three automatic signal adjustment functions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnology\u003c\/th\u003e\n\u003cth\u003eEngineering Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAGC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Gain Control adjusts signal amplitude.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Balance Control maintains signal balance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAOC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Offset Control compensates for signal offset.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese functions help maintain usable optical signals under changing operating conditions. They also reduce sensitivity to minor optical contamination and signal variations. However, they do not eliminate the need for scale cleaning and correct mechanical alignment.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Mechanical Integration and Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Linear Scale Families:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRTLC40\u003c\/li\u003e\n\u003cli\u003eRTLC40-S\u003c\/li\u003e\n\u003cli\u003eRKLC40-S\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the scale model and 40 µm pitch compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect the mounting surface for contamination and mechanical damage.\u003c\/li\u003e\n\u003cli\u003ePosition the readhead according to the applicable installation drawing.\u003c\/li\u003e\n\u003cli\u003eSet the required readhead-to-scale installation height.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified ±0.3 mm height tolerance.\u003c\/li\u003e\n\u003cli\u003eCheck angular alignment within the specified ±0.9° tolerance.\u003c\/li\u003e\n\u003cli\u003eConnect the 15-pin interface to the compatible controller.\u003c\/li\u003e\n\u003cli\u003eProvide a stable 5 V DC supply.\u003c\/li\u003e\n\u003cli\u003eUse the integrated LED to assist setup and alignment checks.\u003c\/li\u003e\n\u003cli\u003eMove the axis slowly and verify stable position feedback.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Recommendation:\u003c\/strong\u003e Avoid excessive cable bending and mechanical stress at the connector. Secure the cable away from motor power cables and high-frequency switching sources.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Controller Integration and Electrical Considerations\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eQ4BCY30D10A\u003c\/strong\u003e provides incremental digital position feedback. Before connecting it to a motion controller, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Compatibility:\u003c\/strong\u003e The controller must provide the specified 5 V DC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Compatibility:\u003c\/strong\u003e Confirm the 15-pin D-type interface and pin assignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e Verify the controller accepts the readhead's output signal format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Compatibility:\u003c\/strong\u003e Check the 10 MHz interface configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution Settings:\u003c\/strong\u003e Configure the controller for 0.1 µm resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Processing:\u003c\/strong\u003e Confirm the controller supports the selected reference mark arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit Inputs:\u003c\/strong\u003e Verify the required limit sensor functions and input assignments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not connect the readhead based on connector shape alone. Confirm the electrical interface and pinout before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Maintenance and Diagnostic Recommendations\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Condition\u003c\/th\u003e\n\u003cth\u003eRecommended Inspection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable position feedback\u003c\/td\u003e\n\u003ctd\u003eInspect optical surfaces, alignment and cable connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference position failure\u003c\/td\u003e\n\u003ctd\u003eCheck reference mark configuration and controller settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent signal loss\u003c\/td\u003e\n\u003ctd\u003eInspect cable routing, connector contacts and supply stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected position counts\u003c\/td\u003e\n\u003ctd\u003eVerify resolution settings and controller signal compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup LED indicates an issue\u003c\/td\u003e\n\u003ctd\u003eFollow the applicable Renishaw setup and diagnostic instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Practice:\u003c\/strong\u003e Keep the optical scale clean and inspect the cable periodically. Avoid abrasive cleaning materials and excessive mechanical force.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Application Areas\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCNC Machine Tools:\u003c\/strong\u003e Linear axis position feedback and motion control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Automation:\u003c\/strong\u003e Position monitoring in automated production equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e High-resolution linear positioning applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetrology Systems:\u003c\/strong\u003e Position feedback for precision measurement platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobotics:\u003c\/strong\u003e Linear actuator and positioning mechanism feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Motion Systems:\u003c\/strong\u003e Closed-loop position control and axis monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e09 | Purchasing, Warranty and Delivery\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRenishaw QUANTiC™ Optical Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ4BCY30D10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 µm pitch \/ 0.1 µm resolution \/ 3.0 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx \/ UPS \/ DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Verification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel number and configuration confirmation before dispatch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Includes a 12-month warranty against covered product defects under the applicable sales terms. Contact our sales team for warranty conditions and claim procedures. \u003cstrong\u003eShipping:\u003c\/strong\u003e International delivery options include FedEx, UPS and DHL. Dispatch arrangements depend on stock status and order confirmation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Technical FAQ – Selection and Engineering Experience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should engineers select the correct scale for this readhead?\u003c\/strong\u003e Start with the 40 µm scale pitch requirement. Then check the mechanical mounting arrangement, scale length and operating environment. Confirm compatibility with RTLC40, RTLC40-S or RKLC40-S before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does 0.1 µm resolution mean the machine achieves 0.1 µm positioning accuracy?\u003c\/strong\u003e No. Resolution describes the smallest digital position increment. Actual positioning accuracy also depends on scale accuracy, mechanical stiffness, thermal expansion, controller performance and installation quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should be checked when the encoder works at low speed but fails at high speed?\u003c\/strong\u003e Check the controller input frequency limit first. Then verify the selected resolution, clock configuration and signal integrity. Excessive cable interference or an incompatible receiver can also affect high-speed operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is a 3-meter cable suitable for every machine installation?\u003c\/strong\u003e Not necessarily. Measure the complete cable route before ordering. Include cable routing, connector access and maintenance clearance. Avoid unnecessary extensions or unverified cable modifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers confirm before purchasing Q4BCY30D10A?\u003c\/strong\u003e Confirm the 40 µm scale pitch, linear configuration, 0.1 µm resolution and 3-meter cable. Also verify the DB15 interface, controller compatibility and reference or limit requirements. Compare the complete ordering code with the installed readhead to avoid configuration mismatches.\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155278327990,"sku":"Q4BCY30D10A","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22Y30D61A-3_f5212f7c-7e7e-43b9-8558-e1ff63ce867e.jpg?v=1795576951"},{"product_id":"rgh22y30d61a-renishaw-precision-rgh22-linear-encoder-system","title":"RGH22Y30D61A Renishaw Precision RGH22 Linear Encoder System","description":"\u003ch3\u003e\u003cstrong\u003ePrecision Position Feedback for Demanding Motion Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1673b9;\"\u003eRenishaw RGH22Y30D61A\u003c\/span\u003e\u003c\/strong\u003e is a non-contact optical encoder readhead from the \u003cstrong\u003eRGH22 series\u003c\/strong\u003e. It provides reliable position feedback for precision linear motion applications. Its open optical architecture eliminates mechanical contact between the readhead and scale.\u003c\/p\u003e\n\u003cp\u003eThe readhead operates with the \u003cstrong\u003eRGS20-S gold tape scale\u003c\/strong\u003e, which features a 20 μm incremental pitch. Integrated interpolation supports resolutions down to 50 nm, depending on the output configuration. Engineers can select compatible analogue or digital signal interfaces for their motion controllers.\u003c\/p\u003e\n\u003cp\u003eSeveral practical features simplify machine integration. An integral setup LED assists optical alignment. Specialized filtering optics improve resistance to contamination. Integrated reference and limit sensors also reduce the need for separate sensing components.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGH22Y30D61A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRGH22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contact Optical Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncremental Optical Position Feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Scale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRGS20-S Gold Tape Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD – 15-way D-sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadhead Mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 45 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot specified in the supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eModel Configuration Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGH22\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIdentifies the RGH22 non-contact optical encoder readhead family.\u003c\/li\u003e\n\u003cli\u003eSupports incremental position measurement with integrated interpolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eY\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIdentifies the specified RGH22 variant.\u003c\/li\u003e\n\u003cli\u003eConfirm the exact electrical output and resolution against the manufacturer's ordering documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration code within the complete ordering reference.\u003c\/li\u003e\n\u003cli\u003eIts precise meaning requires the manufacturer's model-code definition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e15-way D-sub connector configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e61A\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRemaining ordering configuration suffix.\u003c\/li\u003e\n\u003cli\u003eConfirm its electrical and mechanical definitions before selecting a replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Note:\u003c\/strong\u003e The suffix breakdown above distinguishes the supplied connector information from codes requiring further manufacturer documentation. It does not assume undocumented electrical characteristics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Optical Measurement \u0026amp; Signal Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical incremental encoding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Scale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRGS20-S gold tape scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterpolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated interpolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 μm to 50 nm across the RGH22 range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Vpp analogue or RS422 digital, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit Sensors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup Assistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral LED indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecialized filtering optics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Interpretation:\u003c\/strong\u003e The 50 nm figure represents the finest resolution capability stated for the RGH22 family. It should not be interpreted as absolute measurement accuracy or guaranteed system repeatability. Actual performance depends on the readhead variant, scale installation, controller interface, and mechanical system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Electrical Interface \u0026amp; Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA for RGH22Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSELV requirements, IEC BS EN 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Supply Ripple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mVpp at frequencies up to 500 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Output Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 differential signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Output Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Vpp signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Termination Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdditional 25 mA per terminated channel pair at 120 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Termination Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdditional 20 mA with 120 Ω termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-way D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePower Design Consideration:\u003c\/strong\u003e Current consumption figures refer to unterminated readheads. Digital and analogue termination conditions introduce additional current requirements. Size the 5 V supply according to the actual interface configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Cable Construction \u0026amp; Mechanical Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors:\u003c\/strong\u003e 12-core cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Double-shielded construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Diameter:\u003c\/strong\u003e 4.7 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlex Life:\u003c\/strong\u003e More than 20 × 10⁶ cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Bend Radius:\u003c\/strong\u003e 50 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadhead Mass:\u003c\/strong\u003e 45 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Mass:\u003c\/strong\u003e 38 g\/m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe flexible cable supports repeated movement in dynamic machine installations. Double shielding helps reduce susceptibility to electrical interference. Maintain the specified bend radius during cable routing to protect conductor integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Environmental \u0026amp; Operating Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 60068-2-78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Acceleration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 m\/s², 3 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\/s² maximum, 55 Hz to 2000 Hz, 3 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-operating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 m\/s², 6 ms, half-sine, 3 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Environment:\u003c\/strong\u003e IP50 protection does not provide protection against water ingress. Avoid condensation, liquid exposure, and heavy airborne contamination. Use suitable machine guarding when the installation environment requires additional protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation \u0026amp; Optical Alignment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStep 1 – Scale Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClean the mounting substrate before applying the RGS20-S scale. Check the mounting surface for flatness and contamination. Select a substrate compatible with the scale installation method.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2 – Scale Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe RGS20-S uses a specially formulated pre-applied adhesive. Epoxy-fastened end clamps secure the scale. This mounting arrangement minimizes differential movement between the scale and substrate during temperature changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 3 – Readhead Positioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePosition the \u003cstrong\u003eRGH22 readhead\u003c\/strong\u003e according to the manufacturer's optical and mechanical alignment specifications. Maintain the required readhead-to-scale relationship. Avoid mechanical contact with the scale during axis movement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 4 – LED Setup Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the integral setup LED during alignment. Check the indicator according to the manufacturer's installation procedure. Correct optical positioning before finalizing the mounting arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 5 – Electrical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the 15-way D-sub interface to the compatible controller or signal-processing equipment. Verify the 5 V supply polarity and voltage. Check output-interface compatibility before applying power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStep 6 – Motion Validation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMove the axis slowly through its operating range. Confirm incremental signal stability and reference sensor operation. Check limit sensor responses where the machine configuration uses them.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Engineering Applications \u0026amp; Integration Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetrology Equipment:\u003c\/strong\u003e Provides incremental position feedback for precision measuring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Manufacturing:\u003c\/strong\u003e Supports controlled positioning in precision motion assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat Panel Display Production:\u003c\/strong\u003e Provides position feedback for automated linear stages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronics Manufacturing:\u003c\/strong\u003e Supports repeatable motion control in automated production equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Motion Systems:\u003c\/strong\u003e Integrates optical feedback into compatible machine axes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe open optical architecture avoids mechanical contact between the readhead and scale. Filtering optics improve tolerance to dirt contamination. Integrated interpolation reduces the need for separate external interpolation hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Compatibility \u0026amp; Purchasing Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore selecting \u003cstrong\u003e\u003cspan style=\"color: #1673b9;\"\u003eRGH22Y30D61A\u003c\/span\u003e\u003c\/strong\u003e, engineers should verify the following integration details:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm compatibility with the \u003cstrong\u003eRGS20-S 20 μm gold tape scale\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMatch the output type to the motion controller input.\u003c\/li\u003e\n\u003cli\u003eVerify the 15-way D-sub connector arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the 5 V DC power supply capacity.\u003c\/li\u003e\n\u003cli\u003eConfirm the required interpolation resolution.\u003c\/li\u003e\n\u003cli\u003eCheck reference and limit sensor requirements.\u003c\/li\u003e\n\u003cli\u003eVerify cable routing and minimum bend radius.\u003c\/li\u003e\n\u003cli\u003eConfirm mounting geometry and environmental limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Recommendation:\u003c\/strong\u003e When replacing an existing Renishaw encoder, compare the complete part number rather than relying on the RGH22 series designation alone. Output format, connector arrangement, resolution, and scale compatibility determine successful integration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Quality Assurance \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Verification:\u003c\/strong\u003e Part number and configuration checks before order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Support:\u003c\/strong\u003e Assistance with encoder selection and compatibility verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Options:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Areas:\u003c\/strong\u003e Precision motion control, metrology, semiconductor, and electronics manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our team to confirm product availability, configuration details, and purchasing requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does an optical encoder require a reference position during machine startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn incremental encoder measures relative movement rather than automatically identifying an absolute machine coordinate. The controller typically performs a reference operation to establish the machine origin. The integrated reference sensor supports this process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does scale mounting affect positioning accuracy over long travel distances?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eScale mounting stability directly influences the relationship between measured position and actual axis movement. Thermal expansion differences can introduce measurement errors. The RGS20-S adhesive and end-clamp arrangement helps minimize differential movement relative to the substrate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What maintenance action is most useful when optical signal quality deteriorates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the scale surface and readhead alignment before replacing electronic components. Check for oil films, dust accumulation, mechanical movement, and damaged cable shielding. Use the setup LED to assist alignment checks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Should engineers select 50 nm resolution for every precision motion application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Higher resolution does not automatically improve overall positioning accuracy. Evaluate machine stiffness, guideway performance, controller interpolation, scale installation, and feedback bandwidth. Select resolution according to the complete motion-control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when sourcing an RGH22 replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete readhead model, existing scale reference, output interface, connector type, and required resolution. Include the controller model when possible. These details help verify electrical and mechanical compatibility before procurement.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155278360758,"sku":"RGH22Y30D61A","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22Y30D61A-3.jpg?v=1795576841"},{"product_id":"atom4t0-300-renishaw-high-speed-atom-40µm-encoder-readhead","title":"ATOM4T0-300 Renishaw High-Speed ATOM 40µm Encoder Readhead","description":"\u003ch3\u003e\u003cstrong\u003eProduct Identity | Renishaw ATOM Miniature Encoder\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #e87516;\"\u003eRenishaw ATOM4T0-300\u003c\/strong\u003e is a miniature optical incremental encoder readhead. It belongs to the \u003cstrong style=\"color: #e87516;\"\u003eATOM™ 40 µm encoder family\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines a compact optical sensing head with a 3 m cable. It uses a 40 µm scale pitch and supports external digital interpolation.\u003c\/p\u003e\n\u003cp\u003eThe readhead provides non-contact position measurement for precision motion systems. Its compact housing suits equipment with restricted installation space.\u003c\/p\u003e\n\u003cp\u003eThe integrated optical filtering system improves signal stability under normal industrial contamination conditions. Automatic gain control (AGC) and automatic offset control (AOC) support consistent signal conditioning.\u003c\/p\u003e\n\u003cp\u003eA built-in dual-colour LED provides installation feedback. Engineers can check optical alignment without using an oscilloscope during initial setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnderstanding each ordering code helps prevent incorrect interface and scale selection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Section\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eEngineering Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eRenishaw miniature optical incremental encoder system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm optical scale period.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReadhead Type\u003c\/td\u003e\n\u003ctd\u003eCabled version with an interboard connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRTLF40 and RKLF40 linear scales.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-300\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3000 mm (3 m).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete ordering reference:\u003c\/strong\u003e \u003cspan style=\"color: #e87516;\"\u003e\u003cstrong\u003eATOM4T0-300\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant selection note:\u003c\/strong\u003e The T configuration supports compatible Ti, Ri and ACi interfaces. It does not independently identify a top-exit mounting arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Technical Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eTechnical Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eATOM4T0-300\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eATOM™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eMiniature Optical Incremental Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical incremental measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Configuration\u003c\/td\u003e\n\u003ctd\u003eT – Cabled, interboard connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Compatibility Code\u003c\/td\u003e\n\u003ctd\u003e0 – RTLF40 \/ RKLF40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e1 Vpp analogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpolation\u003c\/td\u003e\n\u003ctd\u003eExternal interpolation interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Digital Resolution\u003c\/td\u003e\n\u003ctd\u003eDown to 1 nm with a compatible Ti interface configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Speed\u003c\/td\u003e\n\u003ctd\u003e20 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.35 × 12.7 × 20.5 mm (H × W × L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP40, cabled readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide Height Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.110 mm after calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003eAutomatic gain and offset control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Indicator\u003c\/td\u003e\n\u003ctd\u003eIntegrated dual-colour LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eResolution clarification:\u003c\/strong\u003e The 1 nm figure refers to the available digital interpolation resolution. The Ti interface determines the configured output resolution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Optical and Signal Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ATOM system separates optical detection from electronic interpolation. This arrangement allows engineers to select an interface suited to the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing:\u003c\/strong\u003e Detects incremental graduations on the compatible scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal generation:\u003c\/strong\u003e Produces 1 Vpp analogue signals directly from the readhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal conditioning:\u003c\/strong\u003e AGC and AOC help maintain stable signal characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital interpolation:\u003c\/strong\u003e External electronics convert analogue signals into digital position information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition feedback:\u003c\/strong\u003e The receiving controller processes incremental position and reference information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe integrated optical filtering system helps maintain signal quality. It also improves tolerance to common industrial surface contamination.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Compatible Interfaces and Scales\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInterface selection must match the readhead connection and controller requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eCompatibility \/ Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTi Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-performance digital interpolation interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRi Interface\u003c\/td\u003e\n\u003ctd\u003eExternal interpolation interface for compatible ATOM systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACi Interface\u003c\/td\u003e\n\u003ctd\u003eCompact interface option for compatible system configurations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer PCB\u003c\/td\u003e\n\u003ctd\u003eCustom electronics with suitable signal processing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTLF40\u003c\/td\u003e\n\u003ctd\u003e40 µm stainless-steel linear tape scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRKLF40\u003c\/td\u003e\n\u003ctd\u003e40 µm narrow stainless-steel linear tape scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional scale configurations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCLC40:\u003c\/strong\u003e 40 µm glass linear scale. Requires scale compatibility code 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCDM40:\u003c\/strong\u003e 40 µm glass rotary disc. Requires a suitable rotary compatibility configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering caution:\u003c\/strong\u003e ATOM4T0-300 specifically identifies scale compatibility code 0. Do not assume every ATOM-compatible scale works with this exact configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAccurate mechanical positioning is essential for reliable optical signal generation.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the scale pitch matches the 40 µm readhead configuration.\u003c\/li\u003e\n\u003cli\u003eCheck the scale surface for scratches, oil and foreign particles.\u003c\/li\u003e\n\u003cli\u003eInstall the readhead bracket on a stable machine reference surface.\u003c\/li\u003e\n\u003cli\u003ePosition the readhead within the specified ride height tolerance.\u003c\/li\u003e\n\u003cli\u003eCheck mounting alignment using the integrated LED indicator.\u003c\/li\u003e\n\u003cli\u003eConnect the readhead cable to the compatible interpolation interface.\u003c\/li\u003e\n\u003cli\u003eVerify the interface power supply and electrical connections.\u003c\/li\u003e\n\u003cli\u003eMonitor analogue signal quality during controlled axis movement.\u003c\/li\u003e\n\u003cli\u003eConfigure the required digital resolution in the interpolation interface.\u003c\/li\u003e\n\u003cli\u003eVerify reference mark detection and position counting.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not adjust the readhead solely by visual inspection. Follow the installation drawing and applicable alignment tolerances.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Maintenance and Diagnostic Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indication:\u003c\/strong\u003e Helps engineers identify optical alignment conditions during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic gain control:\u003c\/strong\u003e Compensates for signal amplitude variations within its operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic offset control:\u003c\/strong\u003e Helps maintain balanced analogue signal characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical filtering:\u003c\/strong\u003e Reduces sensitivity to common contamination encountered in factory environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal diagnostics:\u003c\/strong\u003e Compatible system configurations support Renishaw diagnostic tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInspect the optical window and scale periodically. Remove contamination using approved cleaning materials.\u003c\/p\u003e\n\u003cp\u003eCheck cable routing for excessive bending, abrasion and connector stress. Recheck signal quality after mechanical maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Industrial Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe compact housing and high-speed measurement capability support precision motion applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor manufacturing and wafer positioning.\u003c\/li\u003e\n\u003cli\u003ePrecision linear stages and positioning platforms.\u003c\/li\u003e\n\u003cli\u003eElectronics assembly and automated inspection.\u003c\/li\u003e\n\u003cli\u003eCoordinate measuring and dimensional inspection equipment.\u003c\/li\u003e\n\u003cli\u003eHigh-speed automation and motion control systems.\u003c\/li\u003e\n\u003cli\u003ePrecision rotary positioning with compatible glass discs.\u003c\/li\u003e\n\u003cli\u003eCompact machine tools and laboratory instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Environmental and Mechanical Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe open optical design requires suitable environmental protection. The readhead carries an IP40 rating in its cabled configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust:\u003c\/strong\u003e Keep the optical window and scale clean.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquids:\u003c\/strong\u003e Do not expose the readhead to direct liquid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Maintain operation between 0 °C and +60 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Use a rigid mounting bracket to reduce relative movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical interference:\u003c\/strong\u003e Follow Renishaw cable routing and grounding recommendations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical clearance:\u003c\/strong\u003e Check cable movement throughout the complete machine travel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Quality Assurance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct condition:\u003c\/strong\u003e Supplied as a new product in factory packing, subject to order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-delivery inspection:\u003c\/strong\u003e Product identification and external condition checks before shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty period:\u003c\/strong\u003e 12 months from the agreed warranty commencement date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality support:\u003c\/strong\u003e Contact our team if a verified product quality issue occurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical assistance:\u003c\/strong\u003e Support with model identification and interface compatibility checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty terms:\u003c\/strong\u003e The 12-month warranty covers verified product quality defects under normal operating conditions. Damage from incorrect installation, electrical misuse or external mechanical causes is excluded.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Packing and International Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe arrange protective packing for industrial electronic components. The delivery scope follows the confirmed purchase order.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Renishaw ATOM4T0-300 encoder readhead.\u003c\/li\u003e\n\u003cli\u003eIntegrated 3 m cable, as specified by the model.\u003c\/li\u003e\n\u003cli\u003eApplicable product identification and documentation, subject to supply scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eShipping methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFedEx:\u003c\/strong\u003e International express delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPS:\u003c\/strong\u003e International parcel transportation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHL:\u003c\/strong\u003e Express shipping for overseas orders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eShipping options depend on destination, package dimensions and carrier service availability. Please contact us for a delivery quotation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why should engineers select a 40 µm configuration instead of a 20 µm version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe choice depends on the existing scale and required motion performance. A 40 µm system supports speeds up to 20 m\/s. Engineers should also evaluate interpolation resolution and machine accuracy requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if the readhead signal remains unstable despite correct mechanical alignment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the analogue signal amplitude and offset first. Inspect the cable connector and interface supply. Electrical interference or an incompatible interface can also cause unstable feedback.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the ATOM4T0-300 replace an existing encoder from another manufacturer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot as a direct plug-and-play replacement. Compare scale pitch, analogue signal requirements, reference mark arrangement and controller input specifications. Mechanical mounting dimensions also require verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How should buyers choose between Ti, Ri and ACi interfaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the controller architecture and required output resolution. Ti suits high-performance digital interpolation requirements. Ri and ACi provide alternative interface arrangements. Check the specific interface datasheet before selecting the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should purchasing engineers confirm before ordering ATOM4T0-300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the complete part number and 3 m cable requirement. Verify RTLF40 or RKLF40 scale compatibility. Check the existing interpolation interface and required mounting accessories. Request confirmation if the application uses RCLC or RCDM scales.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155293106358,"sku":"ATOM4T0-300","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ATOM4TO-300-1.jpg?v=1795577114"},{"product_id":"q4bcw30d12a-renishaw-quantic-linear-encoder-readhead","title":"Q4BCW30D12A Renishaw QUANTiC Linear Encoder Readhead","description":"\u003ch3\u003e\u003cstrong\u003eRenishaw QUANTiC™ | Digital Position Feedback for Precision Linear Motion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1673b9;\"\u003eQ4BCW30D12A\u003c\/span\u003e\u003c\/strong\u003e is a digital incremental optical encoder readhead from the \u003cstrong\u003eRenishaw QUANTiC™ Q4 series\u003c\/strong\u003e. It provides precise position feedback for industrial linear motion systems.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines a \u003cstrong\u003e40 μm scale pitch\u003c\/strong\u003e, \u003cstrong\u003e0.2 μm digital resolution\u003c\/strong\u003e, and a \u003cstrong\u003e12 MHz clocked output\u003c\/strong\u003e. Its 3-meter cable terminates with a 15-way D-type connector. The readhead supports compatible RTLC40, RTLC40-S, and RKLC40-S linear scales.\u003c\/p\u003e\n\u003cp\u003eThe QUANTiC architecture integrates optical sensing, signal processing, and reference mark functionality. It supports accurate incremental position measurement in demanding automation environments. Engineers can integrate this encoder into precision stages, measuring equipment, and automated positioning systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity \u0026amp; Configuration Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eQ4BCW30D12A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQUANTiC™ Q4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Incremental Optical Linear Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical incremental measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 μm (200 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-way D-type plug, standard pin-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClocked Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Mark\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCustomer selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine-driven alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Part Number Breakdown – Decode Every Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering code identifies the encoder's mechanical, optical, electrical, and signal configurations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eEngineering Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQ4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eQUANTiC 40 μm encoder family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReadhead Type\u003c\/td\u003e\n\u003ctd\u003eStandard linear readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRTLC40 \/ RTLC40-S \/ RKLC40-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e0.2 μm (200 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e15-way D-type plug, standard pin-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClocked Output\u003c\/td\u003e\n\u003ctd\u003e12 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReference \/ Alarm\u003c\/td\u003e\n\u003ctd\u003eCustomer selectable reference mark and line-driven alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4\u003c\/strong\u003e → 40 μm QUANTiC series\u003c\/p\u003e\n\u003cp\u003e└── \u003cstrong\u003eB\u003c\/strong\u003e → Linear readhead\u003c\/p\u003e\n\u003cp\u003e    └── \u003cstrong\u003eC\u003c\/strong\u003e → RTLC40-compatible scale configuration\u003c\/p\u003e\n\u003cp\u003e        └── \u003cstrong\u003eW\u003c\/strong\u003e → 0.2 μm digital resolution\u003c\/p\u003e\n\u003cp\u003e            └── \u003cstrong\u003e30\u003c\/strong\u003e → 3 m cable\u003c\/p\u003e\n\u003cp\u003e                └── \u003cstrong\u003eD\u003c\/strong\u003e → 15-way D-type standard pin-out\u003c\/p\u003e\n\u003cp\u003e                    └── \u003cstrong\u003e12\u003c\/strong\u003e → 12 MHz clocked output\u003c\/p\u003e\n\u003cp\u003e                        └── \u003cstrong\u003eA\u003c\/strong\u003e → Selectable reference mark \/ line-driven alarm\u003c\/p\u003e\n\u003cp\u003eThis configuration structure helps engineers distinguish electrical interface requirements from scale compatibility and resolution options.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Optical Measurement \u0026amp; Digital Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEncoder Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptical incremental encoding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadhead Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital incremental, RS422 interface family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCustomer selectable reference mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine-driven alarm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Reading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible 40 μm linear scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eResolution and Accuracy:\u003c\/strong\u003e The 0.2 μm value represents the configured digital position resolution. It does not represent absolute measurement accuracy. Actual positioning performance also depends on scale installation, machine geometry, controller processing, and mechanical stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Scale Compatibility \u0026amp; Mechanical Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eQ4BCW30D12A\u003c\/strong\u003e is designed for the following 40 μm linear scale configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTLC40:\u003c\/strong\u003e Compatible 40 μm linear scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTLC40-S:\u003c\/strong\u003e Compatible 40 μm stainless steel scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRKLC40-S:\u003c\/strong\u003e Compatible 40 μm steel tape scale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese scale options provide different mechanical installation possibilities. Select the scale according to travel length, substrate material, mounting geometry, and environmental conditions.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the scale's mechanical condition and mounting reference. Check the readhead alignment against the manufacturer's specified installation tolerances.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Reference Mark \u0026amp; Alarm Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCustomer Selectable Reference Mark\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe A configuration supports reference mark selection. A selector magnet activates the required reference position. This function is useful when a scale contains multiple IN-TRAC reference marks.\u003c\/p\u003e\n\u003cp\u003eEngineers can select a specific reference position for machine homing. This arrangement supports applications with multiple possible reference locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLine-Driven Alarm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe configured alarm output uses a line-driven format. It provides an alarm indication when the encoder detects an applicable signal condition. The receiving controller must support the corresponding alarm interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Only the calibrated reference mark provides bidirectional repeatability. Follow the manufacturer's reference mark setup procedure during commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation \u0026amp; Commissioning Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStage 1 – Mechanical Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the linear scale and mounting substrate.\u003c\/li\u003e\n\u003cli\u003eRemove contamination from the installation surface.\u003c\/li\u003e\n\u003cli\u003eCheck the scale position and mounting stability.\u003c\/li\u003e\n\u003cli\u003eVerify the readhead mounting arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStage 2 – Optical Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePosition the readhead according to Renishaw installation instructions.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified readhead-to-scale relationship.\u003c\/li\u003e\n\u003cli\u003eCheck the optical signal during initial alignment.\u003c\/li\u003e\n\u003cli\u003eSecure the readhead after confirming alignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStage 3 – Electrical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the 15-way D-type connector configuration.\u003c\/li\u003e\n\u003cli\u003eCheck the controller's RS422 interface compatibility.\u003c\/li\u003e\n\u003cli\u003eVerify the required 12 MHz clocked output support.\u003c\/li\u003e\n\u003cli\u003eConfirm the reference and alarm input assignments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStage 4 – Functional Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMove the axis through a controlled travel distance.\u003c\/li\u003e\n\u003cli\u003eVerify incremental counting and direction detection.\u003c\/li\u003e\n\u003cli\u003eTest the selected reference mark response.\u003c\/li\u003e\n\u003cli\u003eCheck alarm signal recognition at the controller.\u003c\/li\u003e\n\u003cli\u003eCompare encoder feedback against an independent position reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Maintenance \u0026amp; Diagnostic Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition Drift:\u003c\/strong\u003e Check scale mounting stability and machine thermal behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Interruption:\u003c\/strong\u003e Inspect the cable, connector, and controller interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect Homing:\u003c\/strong\u003e Verify selector magnet position and reference mark configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected Alarm:\u003c\/strong\u003e Check optical alignment and alarm input wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounting Errors:\u003c\/strong\u003e Review signal integrity, controller clock compatibility, and scale condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRegular inspection helps maintain stable encoder feedback. Avoid unnecessary mechanical adjustments before checking electrical signals and alignment conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Engineering Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Linear Stages:\u003c\/strong\u003e Provides incremental position feedback for controlled axis movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCNC Equipment:\u003c\/strong\u003e Supports accurate feedback in compatible linear positioning systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetrology Machines:\u003c\/strong\u003e Supplies digital position information for measurement equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e Supports precision positioning in automated production systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Inspection Systems:\u003c\/strong\u003e Provides repeatable position feedback for scanning and inspection axes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Motion Platforms:\u003c\/strong\u003e Integrates with compatible digital motion controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Compatibility \u0026amp; Replacement Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting a replacement for an existing encoder, verify these five engineering parameters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Pitch:\u003c\/strong\u003e Confirm the existing scale uses a 40 μm pitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Match the required 0.2 μm digital resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Verify the 15-way D-type standard pin-out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClocked Output:\u003c\/strong\u003e Confirm controller support for 12 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Configuration:\u003c\/strong\u003e Verify customer selectable reference marks and line-driven alarm requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not replace an encoder based only on the QUANTiC series name. Different readhead configurations can have different resolutions, connectors, clock frequencies, and reference options.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Warranty, Quality \u0026amp; Global Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Verification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel and configuration verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct selection and compatibility assistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial automation and precision motion systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOur team supports industrial encoder procurement and replacement projects. Contact us to confirm the exact model configuration, availability, and quotation details.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between incremental and absolute encoder feedback?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn incremental encoder measures relative movement through digital signal transitions. The controller establishes the machine coordinate through a reference procedure. An absolute encoder provides a coded position value without requiring the same incremental homing process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why must the controller support the encoder's clock frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe clocked output configuration affects signal communication and processing compatibility. An incompatible controller interface may fail to decode the encoder signals correctly. Verify the 12 MHz specification against the controller's supported input requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: When should engineers use a selectable reference mark instead of outputting every reference mark?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA selectable reference mark suits applications with multiple reference locations. It allows a designated reference position to be activated through a selector magnet. Applications with one reference position may use an all-reference-mark configuration instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can engineers determine whether a replacement readhead will work with an existing scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the scale pitch, scale family, readhead compatibility code, and mounting arrangement. The 40 μm pitch alone does not establish complete compatibility. Confirm the valid readhead and scale combination using Renishaw system configuration documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should buyers consider when choosing between 0.2 μm and finer encoder resolutions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvaluate the required positioning tolerance and the machine's mechanical performance. Finer resolution increases the number of reported position increments. However, it cannot compensate for backlash, structural deformation, thermal expansion, or poor scale installation. Select the resolution according to the complete machine specification.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155343470774,"sku":"Q4BCW30D12A","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22Y30D61A-3_6b2a46ae-02ea-484a-af93-f77864a35d44.jpg?v=1795577270"},{"product_id":"rgs20-s-renishaw-incremental-optical-scale-quantic-rgh-systems","title":"RGS20-S Renishaw Incremental Optical Scale | QUANTiC \u0026 RGH Systems","description":"\u003ch3\u003e\u003cb\u003e01. Product Profile | Precision Linear Scale\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #b8860b;\"\u003eRenishaw RGS20-S\u003c\/span\u003e\u003c\/strong\u003e is a gold-plated steel incremental optical scale for precision linear measurement systems. It uses a reflective optical grating with a 20 µm pitch. The flexible steel construction supports direct installation on precision machine structures. The scale provides incremental position information through compatible Renishaw optical readheads. Its thin profile supports applications with limited mounting space. The adhesive backing simplifies installation. End clamps and structural bonding help maintain stable scale positioning during thermal changes. \u003cstrong\u003ePrimary Engineering Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncremental optical position measurement.\u003c\/li\u003e\n\u003cli\u003eHigh-precision linear motion feedback.\u003c\/li\u003e\n\u003cli\u003eReflective optical scale construction.\u003c\/li\u003e\n\u003cli\u003eDirect mounting on compatible machine substrates.\u003c\/li\u003e\n\u003cli\u003eThermal expansion matching with the mounting structure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e02. Scale Construction | Material and Layer Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS20-S uses a flexible multilayer construction. Each layer serves a specific mechanical or optical function.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial \/ Structure\u003c\/th\u003e\n\u003cth\u003eEngineering Purpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Surface\u003c\/td\u003e\n\u003ctd\u003eGold-plated reflective surface\u003c\/td\u003e\n\u003ctd\u003eProvides the reflective optical reading surface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Substrate\u003c\/td\u003e\n\u003ctd\u003eFlexible steel strip\u003c\/td\u003e\n\u003ctd\u003eProvides mechanical support and dimensional stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Layer\u003c\/td\u003e\n\u003ctd\u003eProtective lacquer coating\u003c\/td\u003e\n\u003ctd\u003eProtects the optical surface during normal service.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Layer\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing\u003c\/td\u003e\n\u003ctd\u003eSupports direct installation on prepared substrates.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd Fixing\u003c\/td\u003e\n\u003ctd\u003eEnd clamps with two-part epoxy adhesive\u003c\/td\u003e\n\u003ctd\u003eSecures the scale ends during installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Selection Advantage:\u003c\/strong\u003e The reflective gold-plated surface supports optical measurement. The flexible steel substrate follows the thermal behavior of its mounting structure when correctly installed.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03. Technical Data | Dimensional and Optical Parameters\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS20-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReflective Incremental Optical Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Technology\u003c\/td\u003e\n\u003ctd\u003eGold-plated steel grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e20 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±3 µm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Range Linearity\u003c\/td\u003e\n\u003ctd\u003e±0.75 µm over 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Width\u003c\/td\u003e\n\u003ctd\u003eApproximately 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThickness\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.15–0.2 mm, including adhesive backing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Length\u003c\/td\u003e\n\u003ctd\u003eApplication-dependent; commonly supplied from 100 mm to 50 m or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with end fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Material\u003c\/td\u003e\n\u003ctd\u003eFlexible steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification Note:\u003c\/strong\u003e Confirm the available length, dimensional tolerances and linearity conditions with the applicable Renishaw technical documentation before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04. Thermal Engineering | Substrate Expansion Matching\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS20-S supports direct mounting on different machine substrates. Compatible substrate materials include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMetal machine structures.\u003c\/li\u003e\n\u003cli\u003eGranite measurement platforms.\u003c\/li\u003e\n\u003cli\u003eCeramic structural components.\u003c\/li\u003e\n\u003cli\u003eComposite machine structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Installation Principle\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePrepare and clean the mounting surface.\u003c\/li\u003e\n\u003cli\u003eAlign the scale along the measurement axis.\u003c\/li\u003e\n\u003cli\u003eApply the adhesive-backed scale to the substrate.\u003c\/li\u003e\n\u003cli\u003eSecure both ends with suitable end clamps.\u003c\/li\u003e\n\u003cli\u003eUse the specified two-part epoxy adhesive for end fixing.\u003c\/li\u003e\n\u003cli\u003eAllow the adhesive to cure according to its technical instructions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWhen correctly installed, the scale follows the thermal expansion behavior of its substrate. This arrangement helps reduce differential expansion errors. \u003cstrong\u003eEngineering Consideration:\u003c\/strong\u003e Substrate material, surface preparation and bonding quality affect long-term measurement stability. Avoid mixing incompatible bonding materials.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05. Readhead Compatibility | Optical System Matching\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS20-S is designed for use with compatible Renishaw RGH optical readheads. \u003cstrong\u003eCompatible Readhead Families:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eReadhead Series\u003c\/th\u003e\n\u003cth\u003eSystem Category\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH22\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH24\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH25\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH26\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Matching Checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 20 µm scale pitch requirement.\u003c\/li\u003e\n\u003cli\u003eConfirm the readhead supports reflective scale operation.\u003c\/li\u003e\n\u003cli\u003eCheck the specified readhead mounting geometry.\u003c\/li\u003e\n\u003cli\u003eVerify the optical gap and alignment requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm the required output resolution and controller interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume compatibility across all Renishaw readhead families. Confirm the exact readhead and scale combination using the relevant technical manual.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06. Installation Quality | Mechanical Preparation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eScale installation directly affects measurement accuracy. Follow a controlled preparation and alignment procedure. \u003cstrong\u003eBefore Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the steel strip for scratches and deformation.\u003c\/li\u003e\n\u003cli\u003eCheck the mounting surface for dust and oil.\u003c\/li\u003e\n\u003cli\u003eConfirm the required scale length and measurement travel.\u003c\/li\u003e\n\u003cli\u003eVerify the mounting surface material and condition.\u003c\/li\u003e\n\u003cli\u003ePrepare compatible end clamps and epoxy adhesive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a straight scale alignment along the travel axis.\u003c\/li\u003e\n\u003cli\u003eAvoid twisting or stretching the flexible steel strip.\u003c\/li\u003e\n\u003cli\u003ePrevent trapped particles beneath the adhesive backing.\u003c\/li\u003e\n\u003cli\u003eSecure the scale ends according to installation instructions.\u003c\/li\u003e\n\u003cli\u003eAllow the adhesive to cure before final measurement checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the scale surface for visible damage.\u003c\/li\u003e\n\u003cli\u003eVerify readhead alignment across the full travel range.\u003c\/li\u003e\n\u003cli\u003eCheck incremental signal stability during axis movement.\u003c\/li\u003e\n\u003cli\u003eConfirm reference positioning and controller feedback.\u003c\/li\u003e\n\u003cli\u003eRecord the installation conditions for future maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e07. Surface Care | Cleaning and Maintenance Protocol\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe protective lacquer requires careful handling. Incorrect solvents can damage the optical surface. \u003cstrong\u003eRecommended Cleaning Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRenishaw-approved cleaning wipes.\u003c\/li\u003e\n\u003cli\u003eIsopropyl alcohol (propan-2-ol).\u003c\/li\u003e\n\u003cli\u003en-Heptane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProhibited Cleaning Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAcetone.\u003c\/li\u003e\n\u003cli\u003eChlorinated solvents.\u003c\/li\u003e\n\u003cli\u003eMethylated spirits (industrial denatured alcohol).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Procedure\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInspect the scale before cleaning.\u003c\/li\u003e\n\u003cli\u003eRemove loose particles using an approved method.\u003c\/li\u003e\n\u003cli\u003eApply the recommended cleaning solvent to a suitable wipe.\u003c\/li\u003e\n\u003cli\u003eClean carefully without scratching the optical surface.\u003c\/li\u003e\n\u003cli\u003eAllow the surface to dry before operating the readhead.\u003c\/li\u003e\n\u003cli\u003eInspect the scale for coating damage or adhesive separation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Warning:\u003c\/strong\u003e Never use aggressive solvents or abrasive tools. They can damage the protective lacquer and affect optical signal quality.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08. Industrial Applications | Motion and Metrology\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCNC Machinery:\u003c\/strong\u003e Linear axis position feedback and precision travel measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoordinate Measuring Machines:\u003c\/strong\u003e Position sensing for precision measurement axes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Metrology:\u003c\/strong\u003e Linear displacement measurement in inspection equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e Precision positioning in automated machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Incremental position feedback for linear motion systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Machine Tools:\u003c\/strong\u003e Scale integration on metal and composite machine structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e09. Procurement Information | Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS20-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eReflective Incremental Optical Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Carriers\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS and DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Confirmation\u003c\/td\u003e\n\u003ctd\u003eSubject to order requirements and stock availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e A 12-month warranty applies to covered product defects under the applicable sales terms. Contact our sales team for warranty coverage and claim procedures. \u003cstrong\u003eInternational Shipping:\u003c\/strong\u003e FedEx, UPS and DHL services are available. Delivery arrangements depend on destination, product availability and order confirmation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10. Engineering FAQ | Selection and Application Guidance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should the required scale length be calculated for a linear axis?\u003c\/strong\u003e Measure the complete working travel first. Then consider readhead movement, reference positioning and end-fixing space. Allow sufficient installation clearance at both ends. Select a scale length that covers the complete mechanical arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What causes measurement drift after a machine reaches operating temperature?\u003c\/strong\u003e Thermal gradients can affect the machine structure and measurement axis. Check substrate temperature distribution and mounting stability first. Also inspect the end clamps and bonding condition. Uneven heating can create errors even with a correctly selected scale.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can engineers install this flexible scale on a granite machine base?\u003c\/strong\u003e Yes, granite is among the stated compatible substrate materials. However, surface preparation and adhesive selection remain important. Verify the bonding procedure and end-fixing method before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should be checked if the optical signal becomes weak after cleaning?\u003c\/strong\u003e Inspect the protective lacquer for scratches or chemical damage. Check for solvent residue and remaining contamination. Then verify readhead alignment and optical clearance. Replace damaged scale sections when the optical surface no longer meets application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Should buyers select the scale by length alone?\u003c\/strong\u003e No. Confirm the 20 µm pitch and compatible RGH readhead first. Then evaluate scale length, substrate material, operating temperature and installation geometry. Also check the required linearity and machine travel before confirming the order.\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155387773110,"sku":"RGS20-S","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGS20-S-3.jpg?v=1795577737"},{"product_id":"rgs40-s-renishaw-40µm-gold-steel-encoder-tape","title":"RGS40-S Renishaw 40µm Gold Steel Encoder Tape","description":"\u003ch3\u003e\u003cstrong\u003eRenishaw RGS40-S | RG4 Series 40 µm Precision Linear Encoder Scale\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRenishaw RGS40-S\u003c\/span\u003e\u003c\/strong\u003e is a reflective, gold-plated steel tape scale designed for high-accuracy incremental linear measurement. It belongs to the \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRGS40 scale family\u003c\/span\u003e\u003c\/strong\u003e and provides a 40 µm graduation pitch.\u003c\/p\u003e\n\u003cp\u003eIts thin steel construction follows the thermal expansion behavior of the mounting substrate. This characteristic helps maintain measurement stability across changing machine temperatures.\u003c\/p\u003e\n\u003cp\u003eThe integrated adhesive backing supports direct installation on prepared metal, granite, ceramic, and composite surfaces. Epoxy-mounted end clamps secure the scale without requiring substrate drilling.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRGS40-S\u003c\/strong\u003e works with compatible \u003cstrong\u003eRenishaw RGH34 and RGH41 readheads\u003c\/strong\u003e. It suits precision machine tools, semiconductor positioning stages, coordinate measurement equipment, and automated inspection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity and Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eRGS40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder System\u003c\/td\u003e\n\u003ctd\u003eRG4 Series Compatible Linear Encoder System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReflective Gold-Plated Steel Tape Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eIncremental Optical Linear Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40 µm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Material\u003c\/td\u003e\n\u003ctd\u003eFlexible steel tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Finish\u003c\/td\u003e\n\u003ctd\u003eGold-plated reflective surface with protective lacquer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eSpecially formulated self-adhesive backing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThickness\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.2 mm, including adhesive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±3 µm\/m; ±1 µm over 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Supply Length\u003c\/td\u003e\n\u003ctd\u003e100 mm to 50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Length\u003c\/td\u003e\n\u003ctd\u003eAbove 50 m by special order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Installation Temperature\u003c\/td\u003e\n\u003ctd\u003e+10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Readheads\u003c\/td\u003e\n\u003ctd\u003eRGH34 and RGH41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Configuration Breakdown and Construction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRGS40-S\u003c\/strong\u003e designation identifies a specific 40 µm steel tape scale configuration. It does not use the same suffix structure as electronic readhead models.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGS40\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRGS: Renishaw reflective steel tape scale family.\u003c\/li\u003e\n\u003cli\u003e40: 40 µm incremental scale pitch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eProtective lacquer surface finish.\u003c\/li\u003e\n\u003cli\u003eGold-plated reflective steel construction.\u003c\/li\u003e\n\u003cli\u003eSelf-adhesive mounting backing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Layers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLayer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReflective Surface\u003c\/td\u003e\n\u003ctd\u003eProvides the optical surface for readhead scanning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Lacquer\u003c\/td\u003e\n\u003ctd\u003eProtects the reflective surface during normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel Substrate\u003c\/td\u003e\n\u003ctd\u003eProvides a thin, flexible dimensional reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive Backing\u003c\/td\u003e\n\u003ctd\u003eSecures the scale to the prepared machine surface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Thermal Behavior and Measurement Accuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS40-S uses a thin-section steel construction. Its thermal behavior follows the mounting substrate after proper installation and end fixing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±3 µm\/m under specified measurement conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Linearity:\u003c\/strong\u003e ±1 µm over a 60 mm measuring length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Matching:\u003c\/strong\u003e The installed scale follows the substrate expansion coefficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstrate Compatibility:\u003c\/strong\u003e Suitable materials have expansion coefficients between 0 and 22 µm\/m\/°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Fixing:\u003c\/strong\u003e Epoxy-mounted clamps prevent uncontrolled scale-end movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e End movement remains below 1 µm over -20 °C to +50 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis thermal arrangement reduces differential movement between the scale and machine structure. It supports repeatable measurements during normal machine temperature changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Consideration:\u003c\/strong\u003e Scale linearity describes the scale itself. Complete machine accuracy also depends on readhead performance, mounting geometry, controller interpolation, and mechanical positioning errors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Installation Architecture and Mounting Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe adhesive-backed design eliminates the need for mounting holes along the scale path. The installation surface must provide adequate flatness, cleanliness, and adhesion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Installation Sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInspect the mounting surface for scratches, burrs, and contamination.\u003c\/li\u003e\n\u003cli\u003eConfirm the substrate expansion coefficient falls within the specified range.\u003c\/li\u003e\n\u003cli\u003eClean and prepare the mounting surface according to Renishaw instructions.\u003c\/li\u003e\n\u003cli\u003eAllow the scale and substrate to reach the installation temperature.\u003c\/li\u003e\n\u003cli\u003eAlign the tape with the machine's intended measurement axis.\u003c\/li\u003e\n\u003cli\u003eApply the adhesive-backed scale without trapping air or creating wrinkles.\u003c\/li\u003e\n\u003cli\u003eSecure both scale ends with epoxy-mounted end clamps.\u003c\/li\u003e\n\u003cli\u003eInstall the compatible readhead and verify its alignment.\u003c\/li\u003e\n\u003cli\u003eCheck incremental signals and reference positioning during commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEnd-Fixing Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9523-4015\u003c\/td\u003e\n\u003ctd\u003eEpoxy-mounted scale end clamps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0342\u003c\/td\u003e\n\u003ctd\u003eTwo-part epoxy adhesive for end fixing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Reference Mark and Limit Switch Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS40-S system supports additional magnetic actuators for reference positioning and travel-limit detection. These accessories work with compatible sensing functions inside the readhead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA. Reference Mark Actuators\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0250\u003c\/td\u003e\n\u003ctd\u003eAdhesive \/ epoxy mounted\u003c\/td\u003e\n\u003ctd\u003eMagnetic reference actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0287\u003c\/td\u003e\n\u003ctd\u003eScrew mounted\u003c\/td\u003e\n\u003ctd\u003eMagnetic reference actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9541-0037\u003c\/td\u003e\n\u003ctd\u003e90° adhesive or screw mounted\u003c\/td\u003e\n\u003ctd\u003eReference actuator for RGH24, RGH25, and RGH34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eInstall one or more reference actuators at selected axis positions.\u003c\/li\u003e\n\u003cli\u003eThe magnetic actuator establishes a repeatable machine datum.\u003c\/li\u003e\n\u003cli\u003eThe reference output synchronizes with incremental channels.\u003c\/li\u003e\n\u003cli\u003eUnidirectional repeatability remains specified within the applicable operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReference Repeatability Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-S Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Variation\u003c\/td\u003e\n\u003ctd\u003e±20 °C from installation temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Field\u003c\/td\u003e\n\u003ctd\u003eSteady ±0.02 T or changing ±7.5 T\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Speed\u003c\/td\u003e\n\u003ctd\u003eRefer to the applicable readhead specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eB. Limit Switch Actuators\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0251\u003c\/td\u003e\n\u003ctd\u003e10 mm adhesive-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-2052\u003c\/td\u003e\n\u003ctd\u003e24.35 mm adhesive-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-2054\u003c\/td\u003e\n\u003ctd\u003e50 mm adhesive-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0285\u003c\/td\u003e\n\u003ctd\u003eFlush-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9541-0040\u003c\/td\u003e\n\u003ctd\u003e90° adhesive or screw-mounted actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLimit Detection Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Method:\u003c\/strong\u003e Magnetic actuator sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition:\u003c\/strong\u003e One or more selected travel positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e 0.1 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose:\u003c\/strong\u003e Provides position-related limit detection for compatible control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Warning:\u003c\/strong\u003e Actuator mounting and sensing arrangements vary by readhead model. Confirm the accessory part number against the exact RGH34 or RGH41 configuration before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Readhead Compatibility and System Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Notes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH34\u003c\/td\u003e\n\u003ctd\u003e40 µm RGS40-S scale\u003c\/td\u003e\n\u003ctd\u003eConfirm output and reference options.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH41\u003c\/td\u003e\n\u003ctd\u003e40 µm RGS40-S scale\u003c\/td\u003e\n\u003ctd\u003eConfirm electrical interface and actuator arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH22\u003c\/td\u003e\n\u003ctd\u003eNot the specified pairing\u003c\/td\u003e\n\u003ctd\u003eDesigned for the 20 µm RGS20 scale family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH24 \/ RGH25\u003c\/td\u003e\n\u003ctd\u003eNot the specified pairing\u003c\/td\u003e\n\u003ctd\u003eCheck the corresponding scale family before selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Selection Rule:\u003c\/strong\u003e Match the scale pitch with the readhead's optical system. A 40 µm scale requires the corresponding RGS40-compatible readhead configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | RGS40-S vs. RGS40-PC: Material Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComparison\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-PC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Material\u003c\/td\u003e\n\u003ctd\u003eGold-plated steel\u003c\/td\u003e\n\u003ctd\u003eGold-plated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Protection\u003c\/td\u003e\n\u003ctd\u003eProtective lacquer\u003c\/td\u003e\n\u003ctd\u003eProtective polyester coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±3 µm\/m\u003c\/td\u003e\n\u003ctd\u003e±5 µm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Linearity\u003c\/td\u003e\n\u003ctd\u003e±1 µm\/60 mm\u003c\/td\u003e\n\u003ctd\u003e±1.5 µm\/60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Compatibility\u003c\/td\u003e\n\u003ctd\u003eRGH34, RGH41\u003c\/td\u003e\n\u003ctd\u003eRGH41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Selection\u003c\/td\u003e\n\u003ctd\u003eStandard precision applications\u003c\/td\u003e\n\u003ctd\u003eApplications requiring improved chemical resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose \u003cstrong\u003eRGS40-S\u003c\/strong\u003e when scale linearity is the primary selection requirement. Consider \u003cstrong\u003eRGS40-PC\u003c\/strong\u003e when exposure to harsh solvents requires additional surface protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Environmental and Maintenance Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10 °C to +120 °C for the scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Temperature:\u003c\/strong\u003e Minimum +10 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstrate:\u003c\/strong\u003e Compatible metals, granite, ceramics, and composites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Condition:\u003c\/strong\u003e Clean, stable, and suitable for adhesive bonding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Exposure:\u003c\/strong\u003e Avoid aggressive solvents on the lacquered surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Check for adhesive lifting, surface damage, and contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse compatible cleaning materials and follow the manufacturer's installation instructions. Avoid acetone, chlorinated solvents, and methylated spirits on the scale.\u003c\/p\u003e\n\u003cp\u003eFor applications involving aggressive solvents or lubricants, evaluate the RGS40-PC polyester-coated alternative.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Certification and Documentation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied specifications identify the material, dimensions, measurement pitch, and operating limits. They do not establish a separate product-specific certification declaration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequest the applicable Renishaw technical datasheet.\u003c\/li\u003e\n\u003cli\u003eConfirm installation requirements against the official scale guide.\u003c\/li\u003e\n\u003cli\u003eVerify machine-level compliance with the relevant industrial standards.\u003c\/li\u003e\n\u003cli\u003eRequest product identification and traceability documentation when required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Package Contents and Supply Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eRenishaw RGS40-S\u003c\/strong\u003e reflective steel tape scale.\u003c\/li\u003e\n\u003cli\u003eSpecified cut length according to the purchase order.\u003c\/li\u003e\n\u003cli\u003eSelf-adhesive backing supplied with the scale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCut-to-length supply from 100 mm to 50 m.\u003c\/li\u003e\n\u003cli\u003eLengths above 50 m require special-order confirmation.\u003c\/li\u003e\n\u003cli\u003eReference actuators and limit actuators require separate selection.\u003c\/li\u003e\n\u003cli\u003eEnd clamps and epoxy adhesive should be specified separately.\u003c\/li\u003e\n\u003cli\u003eReadheads are not included unless the order explicitly states otherwise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Engineering FAQ and Purchasing Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should engineers calculate the required RGS40-S scale length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the machine's measuring travel, then check the readhead's installation geometry and end-fixing allowance. The complete scale length must accommodate the measuring range and required installation margins. Do not order using the nominal axis travel alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if the mounting surface has poor flatness?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocal surface irregularities can affect tape adhesion and readhead alignment. They may also introduce unwanted ride-height variation. Inspect and prepare the substrate before applying the scale. Follow the readhead installation drawing for surface and alignment tolerances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the RGS40-S be installed on an aluminum machine bed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the substrate meets the specified expansion-coefficient range and installation requirements. The thin tape follows the substrate's thermal behavior after correct bonding and end fixing. Always verify the actual machine material and mounting conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: When should a machine builder select RGS40-PC instead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose RGS40-PC when the scale faces greater exposure to aggressive cleaning chemicals or lubricants. Its polyester coating improves chemical resistance. However, its specified linearity differs from RGS40-S. Compare measurement requirements before changing the material configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when requesting a replacement scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the existing scale model, required measuring length, readhead model, substrate material, and operating temperature. Also identify the required reference and limit functions. These details help prevent pitch mismatches and incorrect accessory selection.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155460157622,"sku":"RGS40-S","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGS20-S2-3.jpg?v=1795578128"}],"url":"https:\/\/www.plcsparehub.com\/es\/collections\/renishaw.oembed","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}