{"title":"IFM","description":"\u003cp\u003eThe ifm electronic product portfolio delivers industrial-grade sensor technology, IO-Link connectivity, and distributed control modules designed for automated process monitoring and condition-based maintenance. Engineered with high ingress protection up to IP68\/IP69K, this comprehensive lineup encompasses inductive proximity sensors, pressure transmitters, magnetic-inductive flow meters, and vibration diagnostics units for harsh field environments. Featuring digital IO-Link point-to-point communication interfaces, ifm devices enable lossless telemetry transfer, remote parameter configuration, and real-time device diagnostics directly to PLC backbones or cloud gateways. Our ready-to-ship inventory covers authentic ifm components—including IP67 decentralised I\/O modules, power supplies, and AS-Interface fieldbus nodes—providing field-proven reliability, high noise immunity, and rapid drop-in replacement to minimize operational downtime across modern manufacturing lines.\u003c\/p\u003e","products":[{"product_id":"e30013-ifm-welding-adapter-for-process-sensors-316l-stainless-steel-g1","title":"E30013 IFM Welding Adapter for Process Sensors | 316L Stainless Steel G1","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eE30013\u003c\/span\u003e IFM Welding Adapter for Process Sensors\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eE30013\u003c\/strong\u003e from \u003cstrong\u003eifm electronic\u003c\/strong\u003e is a stainless steel welding adapter designed to provide a process connection for compatible sensors. It features a G 1 sealing-cone sensor connection and a Ø 50 mm welding connection. Its wetted surfaces use 1.4404 \/ 316L stainless steel, with a specified surface finish of Ra less than 0.4 and Rz 4.\u003c\/p\u003e\n\u003cp\u003eFor process engineers and maintenance teams, the main selection factors are sensor interface geometry, process pressure, material compatibility, and the suitability of the welded installation. The adapter has a stated pressure rating of 150 bar for the sensor-to-adapter connection; this value should not automatically be treated as the pressure rating of the entire process assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnection Design at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ifm electronic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e E30013\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct designation:\u003c\/strong\u003e WELDING ADAPT G1 V4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Welding adapter for process sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor connection:\u003c\/strong\u003e G 1 sealing cone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess connection:\u003c\/strong\u003e Ø 50 mm welding adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted material:\u003c\/strong\u003e Stainless steel 1.4404 \/ 316L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface finish:\u003c\/strong\u003e Ra less than 0.4; Rz 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack quantity:\u003c\/strong\u003e 1 piece\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePressure Limits and Application Responsibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies a pressure rating of \u003cstrong\u003e150 bar\u003c\/strong\u003e for the connection between the sensor and adapter. The maximum allowable working pressure (MAWP) listed for applications according to CRN is also 150 bar.\u003c\/p\u003e\n\u003cp\u003eBefore installation, engineers should distinguish the adapter's stated rating from the allowable pressure of the complete assembly. The sensor, adapter interface, weld, process vessel or pipe, and operating conditions must all be suitable for the intended service.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the pressure requirements for the specific process and operating cycle.\u003c\/li\u003e\n\u003cli\u003eConfirm that the selected sensor uses the required G 1 sealing-cone connection.\u003c\/li\u003e\n\u003cli\u003eAssess the welded connection and surrounding process equipment for the intended pressure and temperature conditions.\u003c\/li\u003e\n\u003cli\u003eFor CRN-related applications, review the requirements applicable to the complete installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMaterial and Surface Finish for Process Service\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe wetted parts use stainless steel 1.4404 \/ 316L. The specified surface characteristics are Ra less than 0.4 and Rz 4. These details can be important when selecting process connections for applications that require controlled surface quality or resistance to the process medium.\u003c\/p\u003e\n\u003cp\u003eMaterial suitability still depends on the actual medium, concentration, temperature, cleaning agents, and operating conditions. The manufacturer specifically requires users to check compatibility between the medium and product material for every application. Do not assume that a stainless steel designation alone establishes suitability for every chemical or cleaning process.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe E30013 can be considered for installations using compatible process sensors where a Ø 50 mm welded process connection and G 1 sealing-cone sensor interface meet the mechanical requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure measurement assemblies:\u003c\/strong\u003e For compatible pressure sensors installed on a suitable welded process connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process lines:\u003c\/strong\u003e For sensor mounting where the pipework, weld design, and pressure conditions support the intended installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess vessels and skids:\u003c\/strong\u003e For integrating compatible instruments into engineered process assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance and replacement:\u003c\/strong\u003e For replacing an existing adapter after confirming connection geometry, material, surface finish, and pressure requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are potential application scenarios based on the adapter's connection and material specifications, not a claim of universal compatibility with every sensor, medium, or process system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Engineering Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the sensor interface.\u003c\/strong\u003e Check that the sensor connection is G 1 with the required sealing-cone geometry. A matching nominal thread size alone does not prove interface compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the process opening.\u003c\/strong\u003e Verify that the Ø 50 mm welding-adapter format suits the installation drawing and process connection design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview material compatibility.\u003c\/strong\u003e Evaluate the wetted stainless steel against the actual medium, concentration, temperature, and cleaning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate pressure suitability.\u003c\/strong\u003e Confirm the sensor-to-adapter connection rating and the allowable pressure of the complete welded assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the welded installation.\u003c\/strong\u003e Use the site's approved welding, inspection, and pressure-test procedures for the process equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument the installation.\u003c\/strong\u003e Record the adapter part number, sensor type, process conditions, and inspection results for future maintenance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eField Diagnostics: Finding Connection-Related Problems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe E30013 is a mechanical adapter, not an electronic measurement module. It does not provide its own signal diagnostics. Troubleshooting should therefore focus on the mechanical interface, the sensor, and the installed process connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvidence of leakage:\u003c\/strong\u003e Depressurize and isolate the process according to site procedures, then inspect the sealing interface and installation condition. Do not tighten or remove components under pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor does not seat correctly:\u003c\/strong\u003e Verify the G 1 sealing-cone interface and inspect for damage, contamination, or mismatched connection geometry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeated corrosion or surface damage:\u003c\/strong\u003e Review the process medium, cleaning chemicals, and operating conditions against the material specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure-test failure:\u003c\/strong\u003e Evaluate the sensor seal, adapter interface, weld, and surrounding equipment as separate potential leak paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecurring installation issues:\u003c\/strong\u003e Compare the installed adapter and sensor against the engineering drawing and equipment records before ordering a replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards and Regulatory Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's documentation notes that possible classification under the Pressure Equipment Directive (PED) depends on the application and must be determined by the user or operator. The documentation also states that the adapter is intended for use in devices, machines, and installations outside the categories covered by technical rule TR CU 032\/2013.\u003c\/p\u003e\n\u003cp\u003eThese notes do not establish blanket approval for every installation. The responsible engineer or operator must determine the applicable regulatory requirements for the complete system and intended use.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting a welding adapter, experienced maintenance teams check more than the nominal connection size. The sealing-cone geometry, welded process opening, wetted material, and pressure boundary all influence whether the adapter is appropriate for a specific sensor installation.\u003c\/p\u003e\n\u003cp\u003eFor the \u003cstrong\u003eE30013\u003c\/strong\u003e, the 150 bar figure applies to the sensor-to-adapter connection, while the CRN-related MAWP is also listed as 150 bar. Engineers should still verify the ratings of the sensor, weld, and process equipment before approving the assembly. Material compatibility must be assessed against the actual medium and operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePurchasing Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the exact part number: \u003cstrong\u003eE30013\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMatch the G 1 sealing-cone sensor connection.\u003c\/li\u003e\n\u003cli\u003eVerify the Ø 50 mm welding-adapter process connection.\u003c\/li\u003e\n\u003cli\u003eConfirm the 1.4404 \/ 316L wetted material and specified surface finish.\u003c\/li\u003e\n\u003cli\u003eReview the 150 bar sensor-to-adapter pressure rating and the requirements of the complete assembly.\u003c\/li\u003e\n\u003cli\u003eCheck medium compatibility and any application-specific regulatory requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm quantity and delivery destination when requesting a quotation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's written terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch planning:\u003c\/strong\u003e A 24–48-hour dispatch target may be available after order and stock confirmation. Confirm the actual schedule before purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuotation support:\u003c\/strong\u003e Provide the part number, required quantity, destination, and intended sensor or process connection details to support order review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is a G 1 connection sufficient to confirm that a sensor will fit the E30013?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The sensor must match the specified G 1 sealing-cone interface, not just the nominal connection size. Check the sensor documentation and mechanical drawing before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 150 bar rating be used as the pressure limit for the entire pipework assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot by itself. The stated rating applies to the sensor-to-adapter connection, and the CRN-related MAWP is listed as 150 bar. The sensor, weld, pipework or vessel, and other pressure-boundary components must also meet the applicable operating requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What information is most useful when replacing an adapter in a process line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the existing adapter part number, sensor interface, process connection dimensions, wetted material, operating pressure, and process medium. Photographs and engineering drawings can help identify differences that a nominal thread measurement may miss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the specified stainless steel guarantee compatibility with aggressive cleaning chemicals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Compatibility depends on the chemical composition, concentration, temperature, exposure time, and operating conditions. Evaluate the actual medium against the 1.4404 \/ 316L material specification before approving the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should be investigated if leakage appears after sensor installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst isolate and depressurize the system under the site's safety procedure. Then inspect the sealing-cone interface, sensor compatibility, adapter condition, and welded connection. Use approved inspection and pressure-test methods to identify the leak source before returning the equipment to service.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/E30013.png?v=1792141493\" alt=\"\"\u003e\u003c\/p\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":67651816325302,"sku":"E30013","price":65.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/E30013-3_7d76de49-34aa-41a6-888c-11187fe9fdbd.jpg?v=1792143052"},{"product_id":"igt247-ifm-full-metal-sensor-m18-5-mm-pnp-normally-open-proximity-switch","title":"IGT247 IFM Full-Metal Sensor | M18 5 mm PNP Normally Open Proximity Switch","description":"\u003ch3\u003e\u003cb\u003eIGT247 | IFM Inductive Full-Metal Proximity Sensor\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIFM IGT247\u003c\/strong\u003e is an M18 inductive proximity sensor designed for non-contact detection of metal targets in industrial environments exposed to frequent washdown and aggressive cleaning agents. Its full-metal construction uses 316L stainless steel (1.4404) for the housing and sensing face, while IP68 and IP69K protection support demanding cleaning and moisture-exposure conditions.\u003c\/p\u003e\n\u003cp\u003eThe sensor uses a 5 mm nominal sensing range, a PNP normally open switching output, and a 10–30 V DC supply. Gold-plated M12 connector contacts provide the specified electrical interface. With a listed pressure rating of 100 bar at the sensing face and an operating temperature range of 0 to 100 °C, the device is intended for applications where mechanical durability, hygienic cleaning routines, and reliable metal detection are important.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel identification note:\u003c\/strong\u003e The supplied product information identifies the type designation as \u003cstrong\u003eIGK3005-BPKG\/AM\/US-104\u003c\/strong\u003e and the document\/model reference as \u003cstrong\u003eIGT247-01\u003c\/strong\u003e. Verify the exact ordering code on the product label and manufacturer documentation before purchasing. This page uses IGT247 as the requested product reference.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | The Engineering Snapshot\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct reference\u003c\/td\u003e\n\u003ctd\u003eIGT247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied type designation\u003c\/td\u003e\n\u003ctd\u003eIGK3005-BPKG\/AM\/US-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003eInductive full-metal proximity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing style\u003c\/td\u003e\n\u003ctd\u003eThreaded, M18 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal sensing range\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating distance\u003c\/td\u003e\n\u003ctd\u003e0–4.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput configuration\u003c\/td\u003e\n\u003ctd\u003ePNP, normally open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e10–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage drop\u003c\/td\u003e\n\u003ctd\u003e2.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP68, IP69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient operating temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing and sensing face\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel (1.4404)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003e1 × M12 connector, gold-plated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus indication\u003c\/td\u003e\n\u003ctd\u003eFour yellow LEDs, spaced at 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 55 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e02 | Designed for Aggressive Cleaning Environments\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe full-metal construction is a key selection factor for machinery exposed to regular cleaning. Stainless steel 316L is used for the housing and sensing face, while the listed IP68 and IP69K ratings address protection against water ingress under their applicable test conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequent washdown:\u003c\/strong\u003e Suitable for evaluation in production areas where equipment is regularly cleaned with water or approved cleaning agents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant construction:\u003c\/strong\u003e The 316L stainless-steel surfaces are intended for demanding industrial environments. Actual chemical compatibility still depends on the cleaning agent, concentration, temperature, and exposure duration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure-resistant sensing face:\u003c\/strong\u003e The specified 100 bar pressure rating applies to the sensing face, not automatically to the entire sensor assembly, connector, cable, or installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-direction status indication:\u003c\/strong\u003e Four yellow LEDs positioned at 90° intervals improve visibility of the switching state from different viewing angles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold-plated contacts:\u003c\/strong\u003e The M12 connection uses gold-plated contacts as specified, helping provide the intended connector interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIP69K does not mean unlimited resistance to every chemical or cleaning procedure. Confirm compatibility with the actual washdown chemicals and the connector\/cable assembly, and follow the manufacturer's mounting and cleaning instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Detection Performance and Target-Material Effects\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe nominal sensing range is 5 mm, with a listed operating distance of 0–4.05 mm. The actual switching point depends on target material, target geometry, mounting conditions, and installation tolerances. The supplied correction factors show why target composition matters when setting a detection gap.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget material\u003c\/th\u003e\n\u003cth\u003eCorrection factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe listed hysteresis is 1–20% of the nominal sensing range (Sr). For reliable commissioning, test the actual target material and dimensions rather than assuming that every metal object will be detected at 5 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePractical setup:\u003c\/strong\u003e Start within the specified operating distance, confirm repeatable switching as the target approaches and moves away, and then establish a margin for vibration, mechanical tolerances, and target variation. Copper targets in particular may require a much shorter gap than steel because the listed correction factor is lower.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Electrical Interface and Output Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical feature\u003c\/th\u003e\n\u003cth\u003eEngineering implication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePNP normally open output\u003c\/td\u003e\n\u003ctd\u003eThe output switches positive supply potential to a compatible input or load when the sensor detects a target.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply range: 10–30 V DC\u003c\/td\u003e\n\u003ctd\u003eConfirm the supply remains within range during startup and switching.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current: 100 mA\u003c\/td\u003e\n\u003ctd\u003eKeep the connected load within the rated output current. Use an interface relay or suitable driver for higher-current loads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage drop: 2.5 V DC\u003c\/td\u003e\n\u003ctd\u003eAccount for the voltage drop when checking the voltage available to the receiving input or load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003ePulsed short-circuit protection is specified. Remove the fault rather than repeatedly relying on the protection circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003eProtection is specified; confirm detailed behavior in the manufacturer's documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse-polarity protection\u003c\/td\u003e\n\u003ctd\u003eSpecified as present, but correct polarity and wiring remain necessary for normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency: 100 Hz\u003c\/td\u003e\n\u003ctd\u003eCheck that target passage frequency and required response remain within the sensor's specified switching capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBefore connecting the sensor to a PLC, verify that the receiving input supports PNP switching and that the common wiring is correct. Do not connect the sensor output directly to a load that exceeds its current rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Where the IGT247 Can Be Applied\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage machinery:\u003c\/strong\u003e Detecting metal machine components or product-handling mechanisms in areas subject to routine washdown, where the installation and material compatibility requirements are met.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical and personal-care equipment:\u003c\/strong\u003e Position and presence detection on compatible stainless-steel machinery exposed to frequent cleaning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging lines:\u003c\/strong\u003e Detecting metal carriers, mechanical stops, indexing parts, and moving machine elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilling and conveying systems:\u003c\/strong\u003e Confirming the position of actuators, fixtures, and metal components in wet production environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process equipment:\u003c\/strong\u003e Non-contact position detection in installations where stainless-steel construction and moisture protection are important.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are representative applications for a full-metal inductive sensor. The sensor detects suitable metal targets; it is not a general-purpose detector for plastic, glass, or other non-metallic objects. Confirm that the required sensing distance and target material are suitable before specifying it.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Mechanical Installation and Commissioning\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the ordering code.\u003c\/strong\u003e Compare the product label with the purchasing specification, especially because the supplied information lists both IGT247 and IGK3005-BPKG\/AM\/US-104.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck mounting clearance.\u003c\/strong\u003e Verify the M18 × 1 threaded mounting dimensions, 70 mm overall length, and flush-mounting conditions against the machine design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply the specified tightening torque.\u003c\/strong\u003e The supplied value is 50 Nm. Confirm that this value applies to the intended mounting arrangement and follow the manufacturer's instructions to avoid damaging the sensor or mounting surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the M12 interface.\u003c\/strong\u003e Use a compatible connector and cable assembly rated for the environment. Verify pin assignment and supply polarity from the correct wiring diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the target gap.\u003c\/strong\u003e Adjust the sensor relative to the target material, accounting for the listed correction factor and expected mechanical movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest switching behavior.\u003c\/strong\u003e Move the target through the detection zone and confirm repeatable switching and LED indication. Test under representative operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the PLC input.\u003c\/strong\u003e Confirm that the PNP output is correctly recognized by the connected controller input and that the signal remains stable during machine operation and cleaning cycles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cb\u003e07 | Diagnostic Guide for Field Engineers\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe four yellow LEDs indicate switching status. The supplied data does not establish a dedicated onboard diagnostic interface that identifies every sensor or wiring fault, so troubleshooting should combine LED observation, electrical measurements, target checks, and PLC input status.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003eChecks to perform\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo switching LED when the target approaches\u003c\/td\u003e\n\u003ctd\u003eCheck the DC supply, M12 connector, pin assignment, target material, and sensing gap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED switches but PLC input remains OFF\u003c\/td\u003e\n\u003ctd\u003eVerify PNP\/NPN compatibility, input common wiring, output voltage, cable continuity, and PLC input configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFalse or intermittent switching\u003c\/td\u003e\n\u003ctd\u003eInspect mounting stability, target vibration, electrical interference, connector condition, and target material variation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection distance is shorter than expected\u003c\/td\u003e\n\u003ctd\u003eCheck the target's correction factor, dimensions, alignment, and mounting conditions. Stainless steel, aluminium, and copper have lower listed correction factors than steel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor stops operating after a wiring fault\u003c\/td\u003e\n\u003ctd\u003eRemove power safely, correct the short circuit or overload, and inspect the supply and output circuit before retesting. Protection does not guarantee immunity from every fault condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProblems appear after washdown\u003c\/td\u003e\n\u003ctd\u003eInspect the connector and mating cable, seals, mounting interface, and chemical compatibility. Confirm that the complete installed assembly meets the cleaning conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField diagnostic method:\u003c\/strong\u003e First confirm the supply voltage, then observe the LED response as a known metal target approaches, and finally measure the output and check the PLC input state. This sequence helps separate power, sensing, output-wiring, and controller-interface issues without unnecessary component replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Global PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen a proximity sensor is used in a washdown zone, selection should account for both the sensing task and the cleaning environment. A sensor may have an appropriate ingress-protection rating yet still require verification of chemical compatibility, connector sealing, and the pressure rating applicable to the sensing face.\u003c\/p\u003e\n\u003cp\u003eFor this model, engineers should pay particular attention to the target-material correction factor. A 5 mm nominal range does not guarantee the same operating distance for steel, stainless steel, aluminium, or copper. Confirm the real target material during commissioning and leave adequate distance margin for vibration and mechanical tolerance.\u003c\/p\u003e\n\u003cp\u003eBefore ordering a replacement, check the exact type designation, M18 × 1 mounting, M12 connector, PNP normally open output, and required sensing distance. Because the supplied information contains both an IGT247 reference and an IGK3005-BPKG\/AM\/US-104 type designation, matching the label to the intended part is especially important.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Product Condition, Warranty, and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct reference:\u003c\/strong\u003e IFM IGT247 inductive full-metal sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's warranty terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch estimate:\u003c\/strong\u003e Target dispatch within 24–48 hours after order confirmation, subject to stock availability, payment clearance, and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack quantity:\u003c\/strong\u003e 1 piece; the supplied specification lists two lock nuts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuotation support:\u003c\/strong\u003e Provide the exact type designation, required quantity, and delivery destination to request pricing and verify the correct variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e10 | Frequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Is the 5 mm sensing range guaranteed for stainless-steel targets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The nominal range is 5 mm, but the supplied correction factor for stainless steel is 0.7. Actual switching distance also depends on target dimensions, mounting, and installation tolerances. Validate the sensor against the real target rather than designing around the nominal figure alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. Can I connect the sensor directly to a PLC input designed for NPN sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot without verifying electrical compatibility. This sensor is specified as PNP, normally open. Check the PLC input type, common arrangement, and wiring diagram. If the input requires NPN signaling, an appropriate interface may be needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Does IP69K mean the sensor can withstand every cleaning chemical and pressure-washing procedure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. IP69K describes protection under defined ingress testing conditions; it does not establish universal chemical resistance or unlimited pressure tolerance. Confirm the cleaning chemical, temperature, exposure duration, connector sealing, and applicable pressure rating with the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. What should I inspect if the sensor works before cleaning but fails afterward?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the M12 connector and mating cable, seals, cable routing, mounting interface, and exposure to cleaning chemicals. Also verify supply voltage and output switching after the area is safe to access. Do not assume the sensing element has failed until the complete connection and installation have been inspected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. How do I verify that I am ordering the correct IFM variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete type designation printed on the label with the required part number, and confirm the output type, sensing range, thread size, connector, temperature range, and pressure requirements. The supplied data references both IGT247 and IGK3005-BPKG\/AM\/US-104, so request confirmation against the actual product label before placing the order.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Summary\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IFM IGT247 is described as a full-metal inductive proximity sensor with a 5 mm nominal sensing range, PNP normally open output, M18 × 1 threaded housing, M12 connection, and IP68\/IP69K protection. It is intended for metal-target detection in demanding industrial environments, including applications with frequent cleaning. Verify the exact ordering code, target-material effects, electrical interface, and installation conditions before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IGT247.png?v=1792141551\" alt=\"\"\u003e\u003c\/p\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":67651816947894,"sku":"IGT247","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IGT247.jpg?v=1792142325"},{"product_id":"lr0000b-br34ampkg-us-ifm-lr3000-continuous-liquid-level-transmitter","title":"LR0000B-BR34AMPKG\/US ifm LR3000 Continuous Liquid Level Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eIFM LR3000 Guided Wave Radar Level Sensor — Technical Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003eLR0000B-BR34AMPKG\/US\u003c\/strong\u003e\u003c\/span\u003e, listed in the supplied documentation under the LR3000 product designation, is an ifm continuous level sensor based on guided wave radar technology. It measures liquid level and provides one configurable switching output plus one analog output, with IO-Link communication available through OUT1.\u003c\/p\u003e\n\u003cp\u003eWith a G 3\/4 external process thread, a selectable probe length from 100 to 1600 mm, and configurable analog scaling, this sensor suits liquid-level monitoring in compatible industrial tanks and process vessels. Engineers should evaluate the liquid's dielectric constant, probe geometry, inactive zones, process connection temperature, and output requirements before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Measurement Principle and Application Fit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGuided wave radar determines level using a signal transmitted along a probe. The reflected signal supports continuous level measurement when the liquid and installation meet the sensor's operating requirements. Media properties and probe configuration directly affect whether the sensor can measure reliably.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended media:\u003c\/strong\u003e Water, water-based liquids, oils, and oil-based media within the specified application limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum dielectric constant:\u003c\/strong\u003e 1.8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-dielectric liquids:\u003c\/strong\u003e For media with a dielectric constant between 1.8 and 5, such as certain oils, a coaxial pipe is required for operation according to the supplied specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement method:\u003c\/strong\u003e Guided wave radar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling rate:\u003c\/strong\u003e 4 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe length:\u003c\/strong\u003e 100–1600 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not select the sensor based on tank height alone. Confirm the required measuring span, the usable probe length, the inactive zones, and the liquid's dielectric properties. Consult the operating instructions for media and installation restrictions not reproduced in this product summary.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Probe Geometry, Measuring Range, and Setpoints\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eStandard Media Setting\u003c\/th\u003e\n\u003cth\u003eOil \/ Oil-Based Media Setting\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe length L\u003c\/td\u003e\n\u003ctd\u003e100–1600 mm\u003c\/td\u003e\n\u003ctd\u003e100–1600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive range A\u003c\/td\u003e\n\u003ctd\u003eL − 40 mm\u003c\/td\u003e\n\u003ctd\u003eL − 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInactive range I1 \/ I2\u003c\/td\u003e\n\u003ctd\u003e30 \/ 10 mm\u003c\/td\u003e\n\u003ctd\u003e30 \/ 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet point SP\u003c\/td\u003e\n\u003ctd\u003e≥ 15 to L − 30 mm\u003c\/td\u003e\n\u003ctd\u003e35 to L − 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset point rP\u003c\/td\u003e\n\u003ctd\u003e≥ 10 to L − 35 mm\u003c\/td\u003e\n\u003ctd\u003e30 to L − 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment increment\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGreater than 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering selection note:\u003c\/strong\u003e The active range is shorter than the physical probe length. Oil and oil-based media also have different active and inactive range values. Calculate the usable measurement span using the correct media setting rather than assuming that the entire probe length is measurable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Output Architecture and Control-System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe sensor provides two outputs with different roles. OUT1 supports switching operation or IO-Link, while OUT2 provides the analog measurement signal. Confirm the selected electrical mode and scaling before connecting the device to a PLC, remote I\/O station, or process controller.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eIntegration Consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eOne digital switching output and one analog output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT1\u003c\/td\u003e\n\u003ctd\u003eSwitching output or IO-Link\u003c\/td\u003e\n\u003ctd\u003eConfirm the selected operating mode before wiring and commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching output type\u003c\/td\u003e\n\u003ctd\u003ePNP; normally open or normally closed, parameterisable\u003c\/td\u003e\n\u003ctd\u003eMatch the PLC input type and required switching logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous switching current\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003ctd\u003eKeep the connected load within the specified rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching voltage drop\u003c\/td\u003e\n\u003ctd\u003e2.5 V DC\u003c\/td\u003e\n\u003ctd\u003eInclude the voltage drop when checking input and load margins.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT2 analog current\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, invertible and scalable\u003c\/td\u003e\n\u003ctd\u003eConfigure the output range to match the controller's engineering units.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current-output load\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003eCheck the total loop resistance, including wiring and input resistance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT2 analog voltage\u003c\/td\u003e\n\u003ctd\u003e0–10 V, invertible and scalable\u003c\/td\u003e\n\u003ctd\u003eUse a compatible voltage input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum voltage-output load resistance\u003c\/td\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003eEnsure the receiving input meets the minimum load resistance requirement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection functions\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection and overload protection\u003c\/td\u003e\n\u003ctd\u003eProtection does not replace correct wiring or load selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current and voltage output modes have different electrical requirements. Verify the configured output mode before connecting the sensor to a controller. Do not assume that a single analog terminal configuration simultaneously provides both signal types.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | IO-Link Communication and Parameter Access\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Item\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interface\u003c\/td\u003e\n\u003ctd\u003eIO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link revision\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission type\u003c\/td\u003e\n\u003ctd\u003eCOM2, 38.4 kBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCI standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-9 CDV, as stated in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired master port\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum process cycle time\u003c\/td\u003e\n\u003ctd\u003e2.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess data\u003c\/td\u003e\n\u003ctd\u003e1 analog value and 1 binary value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported DeviceID\u003c\/td\u003e\n\u003ctd\u003eDefault: 344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIO mode\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcyclic IO-Link function\u003c\/td\u003e\n\u003ctd\u003eApplication-specific tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor IO-Link integration, confirm that the master supports the required communication mode and port type. Check the device identification and process-data mapping during commissioning. The supplied specifications list the communication interface and process-data structure but do not provide a complete list of internal diagnostic events or parameter indexes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Accuracy, Resolution, and Signal Scaling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Characteristic\u003c\/th\u003e\n\u003cth\u003eSpecified Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error\u003c\/td\u003e\n\u003ctd\u003e±7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset error\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature drift per 10 K\u003c\/td\u003e\n\u003ctd\u003e±0.2, as specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output endpoints\u003c\/td\u003e\n\u003ctd\u003e4 mA zero signal; 20 mA full signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output endpoints\u003c\/td\u003e\n\u003ctd\u003e0 V zero signal; 10 V full signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eResolution describes the smallest reported increment, not the overall measurement accuracy. When setting PLC scaling, map the configured lower and upper measurement limits to the selected analog output endpoints. The supplied temperature-drift figure does not specify its output unit, so verify the original technical documentation before using it in an error budget.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Process Limits, Materials, and Electrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess connection\u003c\/td\u003e\n\u003ctd\u003eG 3\/4 external thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess temperature\u003c\/td\u003e\n\u003ctd\u003e−25 to 80°C; 90°C for less than 1 hour, subject to the stated remarks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure rating\u003c\/td\u003e\n\u003ctd\u003e16 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum resistance\u003c\/td\u003e\n\u003ctd\u003e−1000 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAWP for CRN applications\u003c\/td\u003e\n\u003ctd\u003e16 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e18–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse-polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-on delay\u003c\/td\u003e\n\u003ctd\u003eLess than 3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e−25 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e−40 to 80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-temperature installation note:\u003c\/strong\u003e The supplied documentation states that the temperature at the process connection determines the permitted operating condition. The actual medium temperature may be higher, so evaluate the connection temperature and follow the technical note for high-temperature service.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Mechanical Construction and Environmental Qualification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 378.4 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted materials listed:\u003c\/strong\u003e Stainless steel 1.4305 \/ 303, probe connection stainless steel 1.4435 \/ 316L, PTFE, and FKM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther listed materials:\u003c\/strong\u003e Stainless steel 1.4301 \/ 304, stainless steel 1.4404 \/ 316L, FKM, PBT, PC, PEI, and TPE-V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeal:\u003c\/strong\u003e NBR reinforced fibre.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e One M12 connector, A-coded, with gold-plated contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e DIN EN 60068-2-27; 50 g for 11 ms, or 25 g for 6 ms with a 0.5 m reference rod.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e DIN EN 60068-2-6; 5 g from 10–2000 Hz, or 1 g from 5–200 Hz with a 0.5 m reference rod.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e DIN EN 61000-6-2 and the applicable DIN EN 61000-6-3 or DIN EN 61000-6-4 conditions stated for closed metal, plastic, or open metal tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTTF:\u003c\/strong\u003e 196 years, as specified in the supplied documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL approval:\u003c\/strong\u003e Approval No. H006; File No. UL E174191.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify material compatibility with the actual liquid, cleaning agents, and operating conditions. The presence of a material in the specification does not establish compatibility with every chemical or process fluid.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Display, Wiring, and Commissioning Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe sensor uses a four-digit alphanumeric display for level indication and parameter setting. Three green LEDs and one yellow switching-status LED provide local visual indication. Use the display and status indicators as initial checks, then confirm the measured signal at the receiving controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the full type designation and the installed probe length before mounting.\u003c\/li\u003e\n\u003cli\u003eCheck that the G 3\/4 process connection matches the vessel fitting and sealing arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify the liquid type and select the correct media setting, especially for oils and oil-based liquids.\u003c\/li\u003e\n\u003cli\u003eSet the switching point and reset point within the allowed ranges for the selected media setting.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected OUT1 function: switching or IO-Link.\u003c\/li\u003e\n\u003cli\u003eConfigure OUT2 for the required current or voltage mode and scale the endpoints to the intended measuring range.\u003c\/li\u003e\n\u003cli\u003eVerify the 18–30 V DC supply, PNP input compatibility, and M12 connector wiring against the official wiring diagram.\u003c\/li\u003e\n\u003cli\u003eAfter power-up, allow for the specified power-on delay of less than 3 seconds, then check the display, switching state, and controller reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied connector notes identify core colours as BN (brown), BU (blue), BK (black), and WH (white), following DIN EN 60947-5-2. Confirm each pin assignment against the official wiring diagram for the exact type before making connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Field Diagnostics: Symptoms and Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Condition\u003c\/th\u003e\n\u003cth\u003eChecks for Maintenance Engineers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel reading does not match the actual liquid level\u003c\/td\u003e\n\u003ctd\u003eCheck the probe length, media setting, inactive zones, setpoint configuration, and installation geometry. Confirm that the liquid meets the dielectric requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil measurement is unstable or unavailable\u003c\/td\u003e\n\u003ctd\u003eVerify the liquid's dielectric constant and whether the required coaxial pipe is installed for the specified dielectric range. Recheck the oil-specific active and inactive range settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC analog value is incorrect\u003c\/td\u003e\n\u003ctd\u003eConfirm whether OUT2 is configured for 4–20 mA or 0–10 V. Check the controller input type, scaling endpoints, loop resistance, and wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching output activates at the wrong level\u003c\/td\u003e\n\u003ctd\u003eReview the SP and rP values, normally open or normally closed setting, selected media mode, and PLC input logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link master does not identify the sensor\u003c\/td\u003e\n\u003ctd\u003eCheck the master port type, COM2 support, wiring, device identification, and configuration. Confirm that OUT1 is available for IO-Link rather than being used in switching mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal indication appears normal but the control system receives no usable signal\u003c\/td\u003e\n\u003ctd\u003eCheck the selected output mode, receiving input configuration, common reference or loop wiring as applicable, and signal measurement at the controller terminals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese are practical fault-isolation steps based on the supplied specifications, not a claim that the device provides a specific built-in alarm for every condition. Use the official operating instructions to identify any additional diagnostic messages and parameter-specific behavior.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor the LR3000 guided wave radar application, reliable selection starts with the liquid rather than the mounting thread. A probe that fits the vessel can still be unsuitable if the medium's dielectric properties, inactive zones, or required measuring span fall outside the supported configuration.\u003c\/p\u003e\n\u003cp\u003eFor oil service, engineers should pay particular attention to the stated coaxial-pipe requirement for media with a dielectric constant between 1.8 and 5, and to the reduced active range specified for oil-based media. Confirm these details before finalising the mechanical installation.\u003c\/p\u003e\n\u003cp\u003eFor PLC integration, treat OUT1 and OUT2 as separate configuration decisions. OUT1 supports switching or IO-Link, while OUT2 provides the analog level signal. Matching the output mode, PLC input type, and scaling endpoints during commissioning helps prevent false level readings and unnecessary sensor replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Warranty, Shipping, and Quotation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's written warranty terms and applicable conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination, availability, and shipping arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e Confirm the exact type designation, probe length, process connection, required output mode, and compatibility with the intended liquid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuotation support:\u003c\/strong\u003e Contact Global PLC Spare HUB to request pricing, availability, lead time, and shipping options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack quantity:\u003c\/strong\u003e 1 piece, according to the supplied product data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e12 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should I choose the probe length for a tank with a known height?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the required operating level span, then account for the sensor's inactive zones and the active-range reduction for the selected media setting. The probe length ranges from 100 to 1600 mm, but the full physical length is not the usable measuring range. Confirm the installation geometry and setpoint limits before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should I check when changing from water to oil service?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReview the dielectric constant and determine whether a coaxial pipe is required. The specified active range and inactive zones also change for oil and oil-based media. Recheck the setpoint limits and confirm that the selected configuration suits the new liquid before commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I connect the sensor directly to a PLC analog input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, if the PLC input matches the selected OUT2 signal mode. The sensor supports a scalable 4–20 mA current output or a scalable 0–10 V voltage output. Check the controller input type, current-loop load or voltage-input resistance, wiring, and engineering-unit scaling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can I reduce false switching near the configured level threshold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the set point and reset point rather than adjusting only the PLC logic. The device provides configurable switching behaviour and a specified hysteresis greater than 5 mm. Verify the chosen media setting and ensure both thresholds remain within the permitted range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should I send when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the type designation from the product label, the LR3000 designation shown in your documentation, probe length, process connection, required output mode, and the liquid being measured. Tank operating temperature and pressure, plus any IO-Link requirement, will help confirm whether the proposed configuration matches your application.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/LR3000.png?v=1792141841\" alt=\"\"\u003e\u003c\/p\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":67651853942966,"sku":"LR3000","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/LR3000-3.jpg?v=1792142351"},{"product_id":"oge500-ifm-through-beam-sensor-receiver-oge-fpkg-us100","title":"OGE500 IFM Through-Beam Sensor Receiver OGE-FPKG\/US100","description":"\u003ch3\u003e\u003cstrong\u003eIFM OGE500 — Through-Beam Photoelectric Sensor Receiver\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eIFM OGE500\u003c\/strong\u003e\u003c\/span\u003e, identified by type designation \u003cstrong\u003eOGE-FPKG\/US100\u003c\/strong\u003e, is a threaded through-beam photoelectric sensor receiver for industrial automation. It receives the red-light beam from a compatible transmitter and changes its PNP switching output according to the configured light-on or dark-on operating mode.\u003c\/p\u003e\n\u003cp\u003eWith an M18 × 1 threaded housing, a detection range specified as less than 25 m, a switching frequency of up to 1,000 Hz, and IP67 protection, this receiver is suitable for presence detection and object monitoring on factory equipment. Correct operation depends on transmitter compatibility, optical alignment, target conditions, and the selected output logic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Operating Principle: What the Receiver Detects\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA through-beam sensor system uses a separate transmitter and receiver mounted opposite each other. The transmitter sends a light beam across the detection path. When an object interrupts the beam, the receiver detects the change and switches its output according to the selected operating mode.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection method:\u003c\/strong\u003e Through-beam photoelectric sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice role:\u003c\/strong\u003e Receiver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight source:\u003c\/strong\u003e Red light, 624 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecified range:\u003c\/strong\u003e Less than 25 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type:\u003c\/strong\u003e PNP switching output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput logic:\u003c\/strong\u003e Programmable light-on or dark-on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory output setting:\u003c\/strong\u003e Dark-on mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause the transmitter and receiver are separate devices, the receiver should not be treated as a standalone reflective sensor. Confirm that the transmitter's optical characteristics and installation arrangement are compatible with the OGE500 before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Electrical Performance and Switching Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and current consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 10–36 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 11 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection class:\u003c\/strong\u003e II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse polarity protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical design:\u003c\/strong\u003e PNP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum DC output voltage drop:\u003c\/strong\u003e 2.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous output current rating:\u003c\/strong\u003e 150 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher current rating condition:\u003c\/strong\u003e 200 mA at 60 °C, as specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC switching frequency:\u003c\/strong\u003e 1,000 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection:\u003c\/strong\u003e Yes, pulsed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PNP output is generally used with compatible PLC digital inputs or control interfaces designed for PNP sensor signals. Before connecting the receiver, check the PLC input type, common-potential arrangement, load current, and input switching thresholds. Do not use the output current rating as a substitute for verifying the electrical requirements of the connected device.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Mechanical Design and Environmental Resistance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing style:\u003c\/strong\u003e Threaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread size:\u003c\/strong\u003e M18 × 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall length:\u003c\/strong\u003e 72 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 50 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing materials:\u003c\/strong\u003e Stainless steel 316L \/ 1.4404, PA, LCP, EPDM, and TPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront lens material:\u003c\/strong\u003e PMMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -25 to +80 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress protection:\u003c\/strong\u003e IP67\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching status indicator:\u003c\/strong\u003e One yellow LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC standard:\u003c\/strong\u003e EN 60947-5-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecified MTTF:\u003c\/strong\u003e 786 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe IP67 rating indicates protection under defined ingress testing conditions; it does not mean that the device is suitable for every chemical, washdown process, or continuous immersion application. Check material compatibility and the installation requirements of the actual production environment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Application Fit: Equipment and Process Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe OGE500 can be considered for equipment that needs reliable beam-interruption detection, provided the transmitter, mounting arrangement, and PLC interface are compatible.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor systems:\u003c\/strong\u003e Detect product presence or gaps as packages pass through a fixed sensing point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging machinery:\u003c\/strong\u003e Monitor product transfer, part passage, or interruptions in a controlled optical path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly lines:\u003c\/strong\u003e Confirm the presence of components before a subsequent machine operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial handling equipment:\u003c\/strong\u003e Detect objects crossing a defined path where suitable mounting positions are available on opposite sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated production stations:\u003c\/strong\u003e Provide a discrete sensor signal for PLC sequencing, interlocks, or process monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor fast-moving objects, evaluate the 1,000 Hz switching frequency alongside PLC input filtering, scan time, object size, and the duration of beam interruption. The sensor's switching frequency alone does not establish the maximum reliable machine cycle rate.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning: Practical Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the pair:\u003c\/strong\u003e Confirm the transmitter is compatible with the OGE500 receiver and that the optical path is within the specified application range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlign the optical axes:\u003c\/strong\u003e Mount the transmitter and receiver facing each other. Adjust their positions to obtain a stable received beam before securing the mounting hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the supply:\u003c\/strong\u003e Measure the DC voltage at the sensor terminals under operating conditions. Keep the supply within 10–36 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the PNP interface:\u003c\/strong\u003e Confirm the PLC input accepts a PNP signal and that the wiring, common connection, and input threshold are correct.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the correct output logic:\u003c\/strong\u003e The factory setting is dark-on. Confirm whether the application requires the output to switch when the beam is interrupted or when the beam is received, and configure the mode accordingly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the complete sequence:\u003c\/strong\u003e Interrupt and restore the beam while monitoring the yellow LED, PLC input state, and machine response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure and protect the installation:\u003c\/strong\u003e Tighten the mounting arrangement appropriately, route the cable or connector away from mechanical damage, and verify sealing after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not assume that the yellow LED alone confirms correct PLC operation. The LED indicates sensor switching status; the PLC input, wiring, and control logic must also be checked during commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Fault Diagnosis: Symptom-Based Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSymptom: The receiver does not switch.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure the supply voltage at the sensor.\u003c\/li\u003e\n\u003cli\u003eCheck transmitter power and confirm that the transmitter is operating.\u003c\/li\u003e\n\u003cli\u003eInspect optical alignment, obstructions, and contamination on the front lens.\u003c\/li\u003e\n\u003cli\u003eVerify the selected light-on\/dark-on mode and observe the yellow status LED.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSymptom: The PLC input remains OFF although the sensor appears to detect the beam.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the PLC input type is compatible with a PNP output.\u003c\/li\u003e\n\u003cli\u003eCheck connector pin assignments, wiring continuity, and the common-potential connection.\u003c\/li\u003e\n\u003cli\u003eMeasure the switching output voltage and compare it with the PLC input's ON threshold.\u003c\/li\u003e\n\u003cli\u003eReview PLC input filtering and channel configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSymptom: The output changes intermittently.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck whether the transmitter and receiver move or vibrate during machine operation.\u003c\/li\u003e\n\u003cli\u003eInspect for temporary beam obstruction, misalignment, or lens contamination.\u003c\/li\u003e\n\u003cli\u003eVerify that the supply voltage remains stable when other loads switch.\u003c\/li\u003e\n\u003cli\u003eReview the object's speed and interruption time relative to the machine's sampling and input-filter settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSymptom: The sensor works during testing but fails after installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck whether the mounting bracket or machine structure shifts the optical alignment.\u003c\/li\u003e\n\u003cli\u003eInspect the M12 connector for incomplete engagement, damaged contacts, or moisture ingress.\u003c\/li\u003e\n\u003cli\u003eConfirm that the operating temperature and environmental conditions remain within the specified limits.\u003c\/li\u003e\n\u003cli\u003eTest the sensor with the actual transmitter and PLC input rather than relying only on an unloaded bench test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The supplied specifications identify a switching-status LED and electrical protection functions, but do not specify a comprehensive diagnostic code system. Use measured supply and output values, LED status, alignment checks, and PLC input monitoring to isolate the fault. Do not infer a specific internal failure without supporting measurements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Selection Guide: Confirm These Details Before Ordering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact designation:\u003c\/strong\u003e Verify OGE500 and type designation OGE-FPKG\/US100 against the existing label or equipment documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice role:\u003c\/strong\u003e Confirm that the required part is the receiver, not the corresponding transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical compatibility:\u003c\/strong\u003e Check the transmitter type, beam arrangement, and required sensing distance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput compatibility:\u003c\/strong\u003e Confirm PNP input compatibility and the required light-on\/dark-on behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical fit:\u003c\/strong\u003e Check the M18 × 1 thread, 72 mm length, available mounting space, and connector clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental suitability:\u003c\/strong\u003e Compare the operating temperature, ingress protection, and housing materials with the installation conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection details:\u003c\/strong\u003e The specified connection is one 4-contact M12 connector, A-coded. Verify the required pinout using the applicable wiring documentation before energizing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering note:\u003c\/strong\u003e The product information lists two lock nuts as supplied accessories and a package quantity of one piece. Confirm the actual supply contents and exact variant when requesting a quotation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Global PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor a through-beam sensor receiver, the most useful troubleshooting approach is to verify the complete optical and electrical path before replacing the device. In conveyor and packaging applications, intermittent detection is often worth investigating at the alignment, mounting, lens condition, and PLC input-filtering stages first. These checks help distinguish a receiver problem from an installation or control-interface issue.\u003c\/p\u003e\n\u003cp\u003eWhen replacing an existing unit, matching the OGE500 designation alone is not enough if the transmitter, output logic, connector wiring, or mounting arrangement differs. Confirm the receiver's PNP interface, factory dark-on setting, M18 × 1 mounting, and compatible transmitter before commissioning the replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Warranty and Worldwide Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month supplier warranty, subject to the supplier's written warranty terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Contact us to confirm availability, exact designation, supplied accessories, and application compatibility before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a quotation, provide the required quantity, destination country, and existing sensor or transmitter model. If this is a replacement order, photos of the product label and connector arrangement can help reduce selection errors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the OGE500 receiver be used by itself to detect an object?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is the receiver in a through-beam sensing arrangement and requires a compatible transmitter to create the optical path. If a single sensor must detect objects without a separate transmitter, evaluate whether a suitable diffuse-reflective or retro-reflective sensor is more appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How should the output mode be selected for a conveyor stop function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by defining the required PLC input state when the beam is clear and when an object blocks it. The OGE500 is factory-set to dark-on mode, but the required logic depends on the control design. Verify the sensor's actual switching behavior and the PLC sequence during commissioning. Do not use the sensor's normal switching behavior as the sole safety function for personnel protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the stated MTTF of 786 years the same as a guaranteed service life?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. MTTF is a statistical reliability measure under defined assumptions; it is not a promise that an individual sensor will operate for that period. Actual service life depends on installation conditions, electrical loading, environmental exposure, and maintenance practices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should be checked when replacing a sensor from another manufacturer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the sensing principle, transmitter compatibility, PNP or NPN output, light-on\/dark-on logic, supply range, switching frequency, connector pinout, mounting dimensions, and environmental requirements. Similar housing dimensions do not guarantee electrical or optical compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How can I determine whether the sensor is suitable for a high-speed production line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the maximum expected object passage rate and beam interruption duration with the sensor's 1,000 Hz switching frequency. Then include PLC input filtering, controller scan behavior, and the machine's response requirements in the evaluation. Conduct a test using the actual product, mounting geometry, and control system before approving the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/OGE500.png?v=1792142159\" alt=\"\"\u003e\u003c\/p\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":67651877929142,"sku":"OGE500","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/OGE500-3.jpg?v=1792142145"}],"url":"https:\/\/www.plcsparehub.com\/collections\/ifm.oembed","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}