{"title":"Hach","description":"\u003cp\u003eOur Hach portfolio provides commercial-grade water quality analysis and fluid monitoring instruments engineered for industrial wastewater, municipal, and process control systems. This comprehensive inventory features advanced sc200 and sc4500 universal controllers, robust online analyzers, and digital sensors integrated with Prognosys predictive diagnostics and Clarify™ data management. Covering critical operational parameters—including pH\/ORP, dissolved oxygen (DO), turbidity, conductivity, and TOC—these instruments utilize optical, electrochemical, and colorimetric measurement principles to deliver precision tracking. Designed for seamless loop integration via ProfiBus, Modbus RTU\/TCP, and 4-20mA analog outputs, these rugged analytical solutions ensure strict regulatory compliance and optimal chemical dosing control. From complete monitoring systems to specialized replacement reagents, electrodeless conductivity probes, and self-cleaning sensors, our genuine Hach parts maintain process stability and lower total cost of ownership in demanding environmental and industrial process streams.\u003c\/p\u003e","products":[{"product_id":"9500-99-05704-polymetron-9500-controller-hach-process-control","title":"9500.99.05704 Polymetron 9500 Controller | HACH Process Control","description":"\u003ch3\u003e\u003cstrong\u003e9500.99.05704 HACH Polymetron 9500 Universal Controller\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003e9500.99.05704\u003c\/span\u003e\u003c\/strong\u003e delivers stable process monitoring for demanding water treatment environments.\u003c\/p\u003e\n\n\u003cp\u003eThe controller supports high-precision conductivity and pH measurement applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003eHACH Polymetron 9500 Series\u003c\/span\u003e\u003c\/strong\u003e targets ultra pure water process control systems.\u003c\/p\u003e\n\n\u003cp\u003eThe platform combines intelligent diagnostics with flexible installation capability.\u003c\/p\u003e\n\n\u003cp\u003eEngineers deploy this controller in continuous monitoring applications requiring reliable sensor integration.\u003c\/p\u003e\n\n\u003cp\u003eThe backlit graphical interface improves visibility in industrial operating conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineered For Critical Water Quality Control\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDesigned for ultra pure water process environments.\u003c\/li\u003e\n\n\u003cli\u003eSupports single-channel and dual-channel configurations.\u003c\/li\u003e\n\n\u003cli\u003eCompatible with Polymetron conductivity and pH sensors.\u003c\/li\u003e\n\n\u003cli\u003eGraphical LCD improves real-time process visibility.\u003c\/li\u003e\n\n\u003cli\u003eFlexible analog output configuration supports automation integration.\u003c\/li\u003e\n\n\u003cli\u003ePID functionality enhances closed-loop process control.\u003c\/li\u003e\n\n\u003cli\u003eDual password protection improves operational security.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial enclosure supports harsh environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003eHACH\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003ePolymetron 9500\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003e9500.99.05704\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Universal Process Controller\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eDisplay Type:\u003c\/strong\u003e Graphic LCD with LED backlight\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eDisplay Resolution:\u003c\/strong\u003e 240 × 160 pixels\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eDisplay Area:\u003c\/strong\u003e 48 mm × 68 mm\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 144 mm × 144 mm × 181 mm\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.70 kg\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 0-95% RH non-condensing\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e Optional isolated 0\/4-20mA outputs\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMaximum Expansion:\u003c\/strong\u003e Supports 5 optional expansion modules\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Impedance:\u003c\/strong\u003e 550 Ω\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Accuracy:\u003c\/strong\u003e ±0.1% FS at 25°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eTemperature Drift Accuracy:\u003c\/strong\u003e ±0.5% FS from -20°C to 60°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eControl Modes:\u003c\/strong\u003e Linear, logarithmic, bilinear, PID\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e NEMA 4X \/ IP66\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMounting Options:\u003c\/strong\u003e Wall, panel, and pipe mounting\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eConduit Opening:\u003c\/strong\u003e 1\/2 NPT\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSecurity Level:\u003c\/strong\u003e Dual password protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIntegrated Diagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eContinuous sensor status monitoring improves measurement reliability.\u003c\/li\u003e\n\n\u003cli\u003eDiagnostic alerts help identify abnormal process conditions quickly.\u003c\/li\u003e\n\n\u003cli\u003eOutput verification improves process control consistency.\u003c\/li\u003e\n\n\u003cli\u003eReal-time display simplifies troubleshooting operations.\u003c\/li\u003e\n\n\u003cli\u003eStable signal processing reduces electrical interference risks.\u003c\/li\u003e\n\n\u003cli\u003eController diagnostics support preventive maintenance planning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eUltra pure water skids\u003c\/li\u003e\n\n\u003cli\u003eSemiconductor water treatment systems\u003c\/li\u003e\n\n\u003cli\u003ePower plant chemistry monitoring systems\u003c\/li\u003e\n\n\u003cli\u003eIndustrial deionized water systems\u003c\/li\u003e\n\n\u003cli\u003eBoiler feedwater treatment equipment\u003c\/li\u003e\n\n\u003cli\u003eProcess conductivity monitoring stations\u003c\/li\u003e\n\n\u003cli\u003epH control automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Application Environments\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSemiconductor manufacturing facilities\u003c\/li\u003e\n\n\u003cli\u003eThermal and nuclear power stations\u003c\/li\u003e\n\n\u003cli\u003ePharmaceutical purified water systems\u003c\/li\u003e\n\n\u003cli\u003eIndustrial process water monitoring\u003c\/li\u003e\n\n\u003cli\u003eElectronics manufacturing plants\u003c\/li\u003e\n\n\u003cli\u003eHigh-purity chemical processing lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003e9500.99.05704\u003c\/span\u003e\u003c\/strong\u003e supports multiple installation configurations for industrial integration.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eWall-mounted installation for centralized monitoring.\u003c\/li\u003e\n\n\u003cli\u003ePanel mounting for compact control cabinet layouts.\u003c\/li\u003e\n\n\u003cli\u003ePipe mounting for skid-based water treatment systems.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial enclosure improves long-term operational stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#005a9c;\"\u003eHACH Polymetron 9500\u003c\/span\u003e\u003c\/strong\u003e provides stable measurement performance in ultra pure water systems.\u003c\/p\u003e\n\n\u003cp\u003eEngineers prefer this controller for conductivity and pH process consistency.\u003c\/p\u003e\n\n\u003cp\u003eThe graphical interface simplifies operator interaction during commissioning.\u003c\/p\u003e\n\n\u003cp\u003eFlexible output configuration improves compatibility with plant automation systems.\u003c\/p\u003e\n\n\u003cp\u003eThe platform performs effectively in semiconductor and power industry applications.\u003c\/p\u003e\n\n\u003cp\u003eIts environmental protection rating supports long-term industrial deployment.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping And Warranty Service\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast dispatch within 24-48 hours after order confirmation.\u003c\/li\u003e\n\n\u003cli\u003eWorldwide delivery available through FedEx, UPS, and DHL.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial protective packaging reduces transportation risk.\u003c\/li\u003e\n\n\u003cli\u003eTechnical support available before shipment.\u003c\/li\u003e\n\n\u003cli\u003e12-month warranty coverage included.\u003c\/li\u003e\n\n\u003cli\u003eProfessional export handling supports international projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does the controller improve process stability in ultra pure water systems?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe controller maintains precise analog signal processing during continuous operation.\u003c\/p\u003e\n\n\u003cp\u003ePID functionality improves response accuracy during process fluctuations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich sensor combinations work best with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConductivity and pH sensor combinations suit high-purity monitoring applications effectively.\u003c\/p\u003e\n\n\u003cp\u003eMany engineers configure dual channels for simultaneous measurement control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat installation method suits semiconductor facilities best?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePanel mounting works well in centralized automation cabinets.\u003c\/p\u003e\n\n\u003cp\u003ePipe mounting suits compact skid-mounted water treatment units.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should engineers verify before selecting expansion modules?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCheck output quantity requirements and control loop architecture first.\u003c\/p\u003e\n\n\u003cp\u003eConfirm analog communication needs before final configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can users improve long-term measurement accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eRegular sensor inspection and scheduled calibration improve process consistency.\u003c\/p\u003e\n\n\u003cp\u003eStable grounding also minimizes electrical noise interference.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSelect dual-channel versions for multi-point monitoring requirements.\u003c\/li\u003e\n\n\u003cli\u003eChoose isolated analog outputs for interference-sensitive environments.\u003c\/li\u003e\n\n\u003cli\u003eUse PID mode in closed-loop chemical dosing applications.\u003c\/li\u003e\n\n\u003cli\u003eConfirm enclosure requirements before outdoor installation.\u003c\/li\u003e\n\n\u003cli\u003eVerify sensor compatibility before commissioning.\u003c\/li\u003e\n\n\u003cli\u003eChoose this controller for high-purity water process stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109423112374,"sku":"9500.99.05704","price":296.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/9500.99.05704.jpg?v=1778133738"},{"product_id":"lxv404-99-00222-sc200-universal-controller-hach-dual-channel-conductivity-system","title":"LXV404.99.00222 sc200 Universal Controller Hach Dual Channel Conductivity System","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eLXV404.99.00222\u003c\/span\u003e Advanced Water Quality Control Platform\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eHach sc200\u003c\/span\u003e\u003c\/strong\u003e delivers flexible water analysis control for industrial and municipal systems.\u003c\/p\u003e\n\n\u003cp\u003eThe controller supports mixed digital and analog sensor architectures.\u003c\/p\u003e\n\n\u003cp\u003eEngineers can deploy the system across multiple monitoring environments efficiently.\u003c\/p\u003e\n\n\u003cp\u003eThe dual-channel platform improves monitoring flexibility and operational continuity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eLXV404.99.00222\u003c\/span\u003e\u003c\/strong\u003e simplifies conductivity integration within complex process applications.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDesigned for Modern Water Analysis Networks\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports simultaneous multi-sensor operation\u003c\/li\u003e\n\u003cli\u003eOptimized for conductivity monitoring applications\u003c\/li\u003e\n\u003cli\u003eCompatible with digital and analog measurement technologies\u003c\/li\u003e\n\u003cli\u003eSupports modular communication integration\u003c\/li\u003e\n\u003cli\u003eLarge display improves field operation visibility\u003c\/li\u003e\n\u003cli\u003ePassword-protected SD card enhances data security\u003c\/li\u003e\n\u003cli\u003eVisual alarm system improves operational awareness\u003c\/li\u003e\n\u003cli\u003eGuided calibration reduces commissioning errors\u003c\/li\u003e\n\u003cli\u003eSupports scalable industrial monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Hach\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eLXV404.99.00222\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003esc200 Universal Controller\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Dual Channel Conductivity Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Configuration:\u003c\/strong\u003e Two analog conductivity sensor inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Digital and analog sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e 2 × 4-20mA outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output:\u003c\/strong\u003e 240 VAC, 5 AMP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 100-240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 50 VA with 7W probe load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 100 VA with 28W probe load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e MODBUS RS232\/RS485, HART, Profibus DPV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Interface:\u003c\/strong\u003e Password-protected SD card slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Type:\u003c\/strong\u003e Large industrial graphical interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Support:\u003c\/strong\u003e Guided calibration workflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Functions:\u003c\/strong\u003e Integrated visual warning system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Type:\u003c\/strong\u003e Panel or system cabinet installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Suitability:\u003c\/strong\u003e Industrial water treatment environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Resistance:\u003c\/strong\u003e Stable operation in electrical noise environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSensor Integration Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eHach sc200\u003c\/span\u003e\u003c\/strong\u003e supports highly flexible sensor deployment.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports two digital sensors simultaneously\u003c\/li\u003e\n\u003cli\u003eSupports two analog sensors simultaneously\u003c\/li\u003e\n\u003cli\u003eSupports hybrid digital and analog configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with GLI conductivity sensors\u003c\/li\u003e\n\u003cli\u003eSupports pH monitoring integration\u003c\/li\u003e\n\u003cli\u003eSupports dissolved oxygen sensor connectivity\u003c\/li\u003e\n\u003cli\u003eSupports industrial flow measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOperational Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eQuick startup architecture reduces commissioning time\u003c\/li\u003e\n\u003cli\u003eClear menu structure simplifies field operation\u003c\/li\u003e\n\u003cli\u003eSecure data storage improves traceability\u003c\/li\u003e\n\u003cli\u003eAdvanced alarm visibility improves response speed\u003c\/li\u003e\n\u003cli\u003eFlexible communication protocols simplify integration\u003c\/li\u003e\n\u003cli\u003eDual-channel capability reduces hardware complexity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and System Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial wastewater treatment systems\u003c\/li\u003e\n\u003cli\u003eMunicipal water treatment facilities\u003c\/li\u003e\n\u003cli\u003eCooling water management systems\u003c\/li\u003e\n\u003cli\u003eBoiler feedwater monitoring platforms\u003c\/li\u003e\n\u003cli\u003eSemiconductor ultrapure water systems\u003c\/li\u003e\n\u003cli\u003eChemical process water applications\u003c\/li\u003e\n\u003cli\u003eFood and beverage process monitoring\u003c\/li\u003e\n\u003cli\u003eEnvironmental water quality stations\u003c\/li\u003e\n\u003cli\u003eSurface water monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eLXV404.99.00222\u003c\/span\u003e\u003c\/strong\u003e provides advanced operational diagnostics for process stability.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports sensor communication verification\u003c\/li\u003e\n\u003cli\u003eProvides calibration status monitoring\u003c\/li\u003e\n\u003cli\u003eDetects abnormal conductivity signal behavior\u003c\/li\u003e\n\u003cli\u003eImproves troubleshooting efficiency during maintenance\u003c\/li\u003e\n\u003cli\u003eSupports fast parameter verification\u003c\/li\u003e\n\u003cli\u003eHelps reduce unplanned process downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0066cc;\"\u003eHach sc200\u003c\/span\u003e\u003c\/strong\u003e remains widely selected for flexible water monitoring architectures.\u003c\/p\u003e\n\n\u003cp\u003eThe controller simplifies mixed sensor integration in demanding process environments.\u003c\/p\u003e\n\n\u003cp\u003eIts communication flexibility benefits distributed industrial automation systems.\u003c\/p\u003e\n\n\u003cp\u003eEngineers value the guided calibration workflow during field commissioning.\u003c\/p\u003e\n\n\u003cp\u003eThe dual-channel structure reduces panel space requirements significantly.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial Logistics and Warranty Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eEach unit undergoes inspection before shipment\u003c\/li\u003e\n\u003cli\u003eFedEx international shipping supported\u003c\/li\u003e\n\u003cli\u003eUPS express logistics available\u003c\/li\u003e\n\u003cli\u003eDHL worldwide delivery supported\u003c\/li\u003e\n\u003cli\u003eProtective industrial export packaging included\u003c\/li\u003e\n\u003cli\u003eFast dispatch available for urgent projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Application Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eUse shielded cables in high-noise environments\u003c\/li\u003e\n\u003cli\u003eMaintain stable grounding for conductivity accuracy\u003c\/li\u003e\n\u003cli\u003eSchedule routine calibration for process consistency\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from power wiring\u003c\/li\u003e\n\u003cli\u003eVerify communication settings before network integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the controller improve conductivity measurement stability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe platform maintains reliable signal processing under fluctuating process conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich communication protocol suits distributed SCADA integration best?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMODBUS RS485 offers stable long-distance industrial communication performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation practice improves signal reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers should isolate sensor cables from high-voltage power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should users select compatible conductivity sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelect sensors based on conductivity range, chemical compatibility, and installation location.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do operators prefer dual-channel monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDual-channel systems reduce hardware footprint and simplify centralized monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109423145142,"sku":"LXV404.99.00222","price":321.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/LXV404.99.00222.jpg?v=1778133749"},{"product_id":"pd1p1-hach-analog-differential-ph-sensor-process-electrode","title":"PD1P1 HACH Analog Differential pH Sensor Process Electrode","description":"\u003ch3\u003e\u003cstrong\u003eAdvanced Liquid Analysis Solution – \u003cspan style=\"color:#c00000;\"\u003e\u003cstrong\u003ePD1P1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003ePD1P1\u003c\/span\u003e\u003c\/strong\u003e differential pH sensor from HACH delivers stable online pH monitoring for industrial process applications.  \nIts differential measurement design improves reliability in harsh environments.  \nThe sensor supports wide-range pH analysis with automatic temperature compensation.  \nIt performs consistently in demanding water treatment and chemical process systems.  \n\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcess Measurement Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement range covers -2.0 to 14.0 pH\u003c\/li\u003e\n\u003cli\u003eAccuracy reaches ±0.02 pH under standard conditions\u003c\/li\u003e\n\u003cli\u003eRepeatability remains within ±0.05 pH\u003c\/li\u003e\n\u003cli\u003eLow drift design improves long-term stability\u003c\/li\u003e\n\u003cli\u003eSupports process temperatures up to 105°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSensor Construction \u0026amp; Materials\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePEEK body resists aggressive chemical environments\u003c\/li\u003e\n\u003cli\u003eTitanium ground electrode improves durability\u003c\/li\u003e\n\u003cli\u003eXLPE cable jacket supports high-temperature operation\u003c\/li\u003e\n\u003cli\u003e1\" NPT threads simplify industrial mounting\u003c\/li\u003e\n\u003cli\u003eConvertible installation structure increases flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTemperature Compensation Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated NTC 300 Ω thermistor enables automatic compensation\u003c\/li\u003e\n\u003cli\u003eSupports manual fixed-temperature adjustment\u003c\/li\u003e\n\u003cli\u003eAdditional correction modes available for pure water applications\u003c\/li\u003e\n\u003cli\u003eOptimized for ammonia and morpholine compensation\u003c\/li\u003e\n\u003cli\u003eImproves pH accuracy during thermal fluctuations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSignal \u0026amp; Communication Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMODBUS communication supports industrial control systems\u003c\/li\u003e\n\u003cli\u003eAnalog cable connection simplifies field integration\u003c\/li\u003e\n\u003cli\u003e5-conductor cable improves signal stability\u003c\/li\u003e\n\u003cli\u003eDual isolated shielding minimizes electrical interference\u003c\/li\u003e\n\u003cli\u003eSuitable for distributed monitoring architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum process pressure reaches 10.7 bar\u003c\/li\u003e\n\u003cli\u003eFlow resistance supports up to 3 m\/s\u003c\/li\u003e\n\u003cli\u003eOperating range from -5°C to 105°C\u003c\/li\u003e\n\u003cli\u003eCompact probe structure simplifies installation\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade sealing improves operational reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eApplication Environment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePure water treatment systems\u003c\/li\u003e\n\u003cli\u003eChemical dosing processes\u003c\/li\u003e\n\u003cli\u003eBoiler water monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater treatment\u003c\/li\u003e\n\u003cli\u003ePower plant water chemistry control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects abnormal pH variation trends rapidly\u003c\/li\u003e\n\u003cli\u003eSupports continuous online process verification\u003c\/li\u003e\n\u003cli\u003eReduces calibration instability in contaminated environments\u003c\/li\u003e\n\u003cli\u003eImproves process consistency and control response\u003c\/li\u003e\n\u003cli\u003eHelps identify chemical imbalance conditions early\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003ePD1P1\u003c\/span\u003e\u003c\/strong\u003e performs well in chemically demanding applications\u003c\/li\u003e\n\u003cli\u003eDifferential sensing reduces reference contamination effects\u003c\/li\u003e\n\u003cli\u003eIts thermal compensation improves process stability\u003c\/li\u003e\n\u003cli\u003eSuitable for continuous industrial water analysis systems\u003c\/li\u003e\n\u003cli\u003eRecommended for facilities requiring long-term measurement consistency\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Warranty Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-month warranty\u003c\/strong\u003e included\u003c\/li\u003e\n\u003cli\u003eExpress delivery via FedEx, UPS and DHL\u003c\/li\u003e\n\u003cli\u003eSecure industrial export packaging\u003c\/li\u003e\n\u003cli\u003eFast shipment within 24–48 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhy does differential measurement improve stability?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIt minimizes contamination influence on the reference system.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eHow to improve sensor service life?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaintain stable flow conditions and clean the sensor regularly.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eWhat should engineers verify before installation?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCheck pressure compatibility and process chemical conditions.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eWhich applications benefit most from this sensor?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHigh-temperature and chemically aggressive water systems.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eWhat is a practical calibration recommendation?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUse fresh buffer solutions and calibrate under operating temperature conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109423341750,"sku":"PD1P1","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PD1P1.jpg?v=1778133759"},{"product_id":"hach-drc2k5n-series-ph-orp-sensor-platinum-electrode-module","title":"HACH DRC2K5N Series pH ORP Sensor | Platinum Electrode Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#cc0000;\"\u003eHACH DRC2K5N\u003c\/span\u003e\u003c\/strong\u003e is a high-performance digital combination pH\/ORP sensor for industrial process control.\u003c\/p\u003e\n\n\u003cp\u003eThis sensor supports stable ORP measurement in demanding liquid monitoring environments.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor uses a durable PVDF body for chemical resistance and long operating life.\u003c\/p\u003e\n\n\u003cp\u003eThe platinum electrode delivers reliable oxidation-reduction potential detection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#cc0000;\"\u003eHACH DRC2K5N Series\u003c\/span\u003e\u003c\/strong\u003e supports water treatment, chemical processing, and industrial automation systems.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated cable design simplifies installation and improves signal integrity.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor performs consistently under high temperature and high-pressure conditions.\u003c\/p\u003e\n\n\u003cp\u003eIts double-junction construction minimizes contamination risks during continuous operation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#cc0000;\"\u003eHACH DRC2K5N\u003c\/span\u003e\u003c\/strong\u003e provides dependable ORP monitoring for critical industrial processes.\u003c\/p\u003e\n\n\u003cp\u003eThe PVDF housing performs well in corrosive chemical environments.\u003c\/p\u003e\n\n\u003cp\u003eThe platinum sensing element ensures fast electrochemical response.\u003c\/p\u003e\n\n\u003cp\u003eThis model suits industrial controllers requiring stable digital ORP measurement.\u003c\/p\u003e\n\n\u003cp\u003eEngineers often select this sensor for wastewater treatment and chemical dosing systems.\u003c\/p\u003e\n\n\u003cp\u003eThe long transmission capability supports large-scale industrial installations.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor integrates efficiently with HACH sc controllers and digital gateway systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial water treatment systems\u003c\/li\u003e\n\u003cli\u003eWastewater process monitoring\u003c\/li\u003e\n\u003cli\u003eChemical dosing control systems\u003c\/li\u003e\n\u003cli\u003eCooling tower water analysis\u003c\/li\u003e\n\u003cli\u003eBoiler water treatment systems\u003c\/li\u003e\n\u003cli\u003eProcess liquid oxidation monitoring\u003c\/li\u003e\n\u003cli\u003eFood and beverage process control\u003c\/li\u003e\n\u003cli\u003ePharmaceutical liquid processing\u003c\/li\u003e\n\u003cli\u003eIndustrial automation platforms\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#cc0000;\"\u003eDRC2K5N\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Combination pH\/ORP Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e -2000 to 2000 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e ±20 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode Material:\u003c\/strong\u003e Platinum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e PVDF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted Materials:\u003c\/strong\u003e PVDF, PTFE, Glass, Platinum, FKM\/FPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 0°C to 105°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Resistance:\u003c\/strong\u003e 0 to 6.9 bar at 100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Transmission Distance:\u003c\/strong\u003e Up to 1000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Cable:\u003c\/strong\u003e Integral coaxial cable, 4.5 m length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Thread Size:\u003c\/strong\u003e 0.75 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Fast electrochemical response design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Optimized platinum electrode sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e High-resolution digital ORP monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Stable linear output across full range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Excellent chemical resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-Interference Capability:\u003c\/strong\u003e Enhanced signal stability with coaxial shielding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Characteristics:\u003c\/strong\u003e Industrial-grade corrosion resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatibility Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompatible with HACH sc100 controllers\u003c\/li\u003e\n\u003cli\u003eSupports HACH Digital Gateway systems\u003c\/li\u003e\n\u003cli\u003eWorks with industrial process automation platforms\u003c\/li\u003e\n\u003cli\u003eSuitable for distributed monitoring networks\u003c\/li\u003e\n\u003cli\u003eSupports long-distance signal transmission applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the sensor in stable liquid flow conditions\u003c\/li\u003e\n\u003cli\u003eAvoid direct exposure to strong mechanical vibration\u003c\/li\u003e\n\u003cli\u003eKeep cable routing away from high-voltage power lines\u003c\/li\u003e\n\u003cli\u003eVerify thread compatibility before installation\u003c\/li\u003e\n\u003cli\u003eEnsure correct immersion depth during operation\u003c\/li\u003e\n\u003cli\u003eInspect sealing components before startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eCalibrate the sensor before initial operation\u003c\/li\u003e\n\u003cli\u003eUse compatible calibration solutions for accurate setup\u003c\/li\u003e\n\u003cli\u003eClean the electrode regularly to maintain stability\u003c\/li\u003e\n\u003cli\u003eInspect cable integrity during scheduled maintenance\u003c\/li\u003e\n\u003cli\u003eReplace worn sealing components when necessary\u003c\/li\u003e\n\u003cli\u003eStore the sensor in clean conditions during downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports stable ORP trend monitoring\u003c\/li\u003e\n\u003cli\u003eHelps identify process oxidation fluctuations\u003c\/li\u003e\n\u003cli\u003eImproves dosing system response efficiency\u003c\/li\u003e\n\u003cli\u003eReduces unexpected process interruptions\u003c\/li\u003e\n\u003cli\u003eSupports predictive maintenance planning\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertification Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eManufactured according to industrial quality standards\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial automation applications\u003c\/li\u003e\n\u003cli\u003eDesigned for harsh process environments\u003c\/li\u003e\n\u003cli\u003eSupports reliable long-term operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#cc0000;\"\u003eHACH DRC2K5N\u003c\/span\u003e\u003c\/strong\u003e Digital pH\/ORP Sensor\u003c\/li\u003e\n\u003cli\u003e1 × Integrated 4.5 m sensor cable\u003c\/li\u003e\n\u003cli\u003e1 × Product inspection documentation\u003c\/li\u003e\n\u003cli\u003e1 × Installation and operating guidance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eWorldwide shipping available\u003c\/li\u003e\n\u003cli\u003eCourier partners: FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eTypical dispatch time: 24-48 hours\u003c\/li\u003e\n\u003cli\u003eProtective industrial export packaging\u003c\/li\u003e\n\u003cli\u003eTracking information provided after shipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty coverage\u003c\/li\u003e\n\u003cli\u003eTechnical support available during warranty period\u003c\/li\u003e\n\u003cli\u003eProfessional pre-sales and after-sales assistance\u003c\/li\u003e\n\u003cli\u003eQuality inspection before shipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does the \u003cspan style=\"color:#cc0000;\"\u003eHACH DRC2K5N\u003c\/span\u003e sensor measure?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe sensor measures oxidation-reduction potential in industrial liquid processes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich industries commonly use this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWater treatment, chemical processing, and industrial automation industries frequently use this model.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this sensor operate in high-temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The sensor supports temperatures up to 105°C.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes the sensor support long-distance signal transmission?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. It supports transmission distances up to 1000 meters with compatible systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy do engineers prefer PVDF sensor bodies?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePVDF provides strong chemical resistance and excellent durability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should users calibrate the sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCalibration frequency depends on process conditions and liquid contamination levels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat installation practice improves signal stability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eSeparate sensor cables from power cables to reduce electrical interference.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can users extend electrode service life?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eRegular cleaning and stable process conditions help maximize electrode lifespan.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich systems work best with this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eHACH digital controllers and industrial process monitoring systems work efficiently.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should buyers consider before selection?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCheck process temperature, chemical compatibility, pressure conditions, and controller compatibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this model suitable for wastewater applications?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. Many facilities use this sensor for wastewater oxidation monitoring.\u003c\/p\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109424029878,"sku":"DRC2K5N","price":324.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DRC2K5N.jpg?v=1778133769"},{"product_id":"drc1r5n-hach-digital-orp-sensor-platinum-combination-electrode","title":"DRC1R5N HACH Digital ORP Sensor | Platinum Combination Electrode","description":"\u003ch3\u003e\u003cstrong\u003eDRC1R5N HACH Digital Combination pH\/ORP Sensor\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eDRC1R5N\u003c\/span\u003e\u003c\/strong\u003e delivers stable ORP monitoring performance in demanding industrial liquid analysis systems.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor combines durable construction with precise oxidation-reduction potential measurement capability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eHACH DRC1R5N\u003c\/span\u003e\u003c\/strong\u003e supports continuous process monitoring applications requiring reliable signal stability.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated platinum electrode improves long-term electrochemical response consistency.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor architecture supports industrial water treatment and chemical process environments.\u003c\/p\u003e\n\n\u003cp\u003eIts digital communication capability enhances long-distance signal transmission reliability.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcess Measurement Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eWide ORP measurement range supports complex industrial applications.\u003c\/li\u003e\n\n\u003cli\u003ePlatinum sensing element improves electrochemical responsiveness.\u003c\/li\u003e\n\n\u003cli\u003ePPS body construction resists aggressive process conditions.\u003c\/li\u003e\n\n\u003cli\u003eStable operation supports continuous online monitoring systems.\u003c\/li\u003e\n\n\u003cli\u003eLong transmission capability improves remote installation flexibility.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial sealing materials improve environmental durability.\u003c\/li\u003e\n\n\u003cli\u003eDigital gateway integration enhances signal integrity.\u003c\/li\u003e\n\n\u003cli\u003eCoaxial cable structure reduces electrical interference impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eHACH\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eDRC1R5N\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Digital Combination pH\/ORP Sensor\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e -2000 to 2000 mV\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e ±20 mV\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eElectrode Material:\u003c\/strong\u003e Platinum\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e PPS\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWetted Materials:\u003c\/strong\u003e PPS, PTFE, glass, platinum, FKM\/FPM O-rings\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 0°C to 105°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e 0 to 6.9 bar at 100°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eFlow Velocity:\u003c\/strong\u003e 0 to 2 m\/s\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSensor Thread:\u003c\/strong\u003e 0.75 inch\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e Integral coaxial cable\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 5.5 m\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSignal Transmission Distance:\u003c\/strong\u003e Up to 1000 m\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e None\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eRecommended pH Range:\u003c\/strong\u003e 2.5 to 12.5 pH\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eDRC1R5N\u003c\/span\u003e\u003c\/strong\u003e analog ORP sensor\u003c\/li\u003e\n\n\u003cli\u003e1 × AD 1200 Digital Gateway\u003c\/li\u003e\n\n\u003cli\u003e1 × 1-meter digital extension cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial water quality analyzers\u003c\/li\u003e\n\n\u003cli\u003eHACH sc100 controller systems\u003c\/li\u003e\n\n\u003cli\u003eProcess chemical dosing skids\u003c\/li\u003e\n\n\u003cli\u003eCooling water monitoring equipment\u003c\/li\u003e\n\n\u003cli\u003eWastewater oxidation monitoring systems\u003c\/li\u003e\n\n\u003cli\u003eIndustrial disinfection control platforms\u003c\/li\u003e\n\n\u003cli\u003eSemiconductor water treatment systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial wastewater treatment plants\u003c\/li\u003e\n\n\u003cli\u003eChemical process monitoring systems\u003c\/li\u003e\n\n\u003cli\u003eCooling tower water quality control\u003c\/li\u003e\n\n\u003cli\u003eUltra pure water process lines\u003c\/li\u003e\n\n\u003cli\u003ePower generation water treatment facilities\u003c\/li\u003e\n\n\u003cli\u003eOxidation and disinfection process monitoring\u003c\/li\u003e\n\n\u003cli\u003eContinuous ORP control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic And Operational Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eStable signal transmission supports remote monitoring applications.\u003c\/li\u003e\n\n\u003cli\u003eDigital gateway architecture improves communication reliability.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial-grade sealing reduces process leakage risks.\u003c\/li\u003e\n\n\u003cli\u003ePlatinum electrode design improves measurement repeatability.\u003c\/li\u003e\n\n\u003cli\u003eCoaxial signal structure minimizes electrical noise influence.\u003c\/li\u003e\n\n\u003cli\u003eLong-distance communication simplifies distributed installation layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eHACH DRC1R5N\u003c\/span\u003e\u003c\/strong\u003e performs effectively in demanding oxidation-reduction monitoring applications.\u003c\/p\u003e\n\n\u003cp\u003eThe platinum sensing element provides reliable electrochemical stability during continuous operation.\u003c\/p\u003e\n\n\u003cp\u003eEngineers often deploy this sensor in water treatment and chemical dosing systems.\u003c\/p\u003e\n\n\u003cp\u003eThe PPS structure improves durability in aggressive industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eIts long communication capability supports centralized analyzer installations.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor suits facilities requiring stable ORP trend monitoring performance.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the sensor in stable process flow locations.\u003c\/li\u003e\n\n\u003cli\u003eAvoid direct exposure to excessive mechanical vibration.\u003c\/li\u003e\n\n\u003cli\u003eMaintain clean electrical grounding during installation.\u003c\/li\u003e\n\n\u003cli\u003eUse compatible mounting hardware for pressure-rated systems.\u003c\/li\u003e\n\n\u003cli\u003eVerify cable routing to reduce electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eLogistics And Warranty Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast shipment within 24-48 hours.\u003c\/li\u003e\n\n\u003cli\u003eGlobal delivery available through FedEx, UPS, and DHL.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial protective packaging improves transport safety.\u003c\/li\u003e\n\n\u003cli\u003eExport-ready packaging supports international projects.\u003c\/li\u003e\n\n\u003cli\u003e12-month warranty service included.\u003c\/li\u003e\n\n\u003cli\u003eTechnical support available for product integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy does platinum electrode material matter in ORP applications?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePlatinum provides stable electrochemical response in demanding oxidation environments.\u003c\/p\u003e\n\n\u003cp\u003eIt also improves long-term signal consistency during continuous operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can engineers improve sensor lifespan in harsh process conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eRegular cleaning and controlled flow conditions reduce coating accumulation.\u003c\/p\u003e\n\n\u003cp\u003eStable process temperature also improves operational durability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should users consider before selecting transmission distance requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eVerify controller compatibility and gateway architecture before installation.\u003c\/p\u003e\n\n\u003cp\u003eLong cable routing requires proper shielding practices.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich applications benefit most from digital gateway integration?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDistributed monitoring systems benefit from improved communication stability.\u003c\/p\u003e\n\n\u003cp\u003eRemote analyzer cabinets also gain installation flexibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow should users select ORP sensors for chemical dosing systems?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eReview process temperature, pressure, and chemical compatibility carefully.\u003c\/p\u003e\n\n\u003cp\u003ePlatinum electrode designs work well in oxidation monitoring applications.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eChoose \u003cstrong\u003e\u003cspan style=\"color:#0b6e4f;\"\u003eDRC1R5N\u003c\/span\u003e\u003c\/strong\u003e for stable ORP monitoring applications.\u003c\/li\u003e\n\n\u003cli\u003eSelect this model for long-distance industrial signal transmission.\u003c\/li\u003e\n\n\u003cli\u003eUse PPS-body sensors in chemically demanding environments.\u003c\/li\u003e\n\n\u003cli\u003eChoose platinum electrodes for reliable oxidation measurement stability.\u003c\/li\u003e\n\n\u003cli\u003eVerify controller compatibility before system integration.\u003c\/li\u003e\n\n\u003cli\u003eConsider process pressure and temperature before deployment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109424455862,"sku":"DRC1R5N","price":348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DRC1R5N.jpg?v=1778133779"},{"product_id":"dpc3k2a-hach-combination-ph-orp-sensor-digital-process-analyzer-probe","title":"DPC3K2A HACH Combination pH ORP Sensor Digital Process Analyzer Probe","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eDPC3K2A\u003c\/span\u003e Industrial Digital pH\/ORP Measurement Sensor\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eHACH DPC3K2A\u003c\/span\u003e\u003c\/strong\u003e combines process-grade pH monitoring with stable digital signal transmission.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor supports continuous industrial liquid analysis under demanding operating conditions.\u003c\/p\u003e\n\n\u003cp\u003eIts integrated digital architecture improves measurement reliability across long transmission distances.\u003c\/p\u003e\n\n\u003cp\u003eThe corrosion-resistant body structure supports aggressive water treatment environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eDPC3K2A\u003c\/span\u003e\u003c\/strong\u003e fits industrial automation systems requiring stable pH process control.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Process Measurement Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDesigned for industrial pH and ORP process monitoring\u003c\/li\u003e\n\u003cli\u003eSupports stable digital signal communication\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose glass electrode improves process adaptability\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature compensation improves measurement consistency\u003c\/li\u003e\n\u003cli\u003eSupports long-distance signal transmission architecture\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant wetted materials improve service life\u003c\/li\u003e\n\u003cli\u003eOptimized for harsh industrial water environments\u003c\/li\u003e\n\u003cli\u003eSupports continuous online monitoring applications\u003c\/li\u003e\n\u003cli\u003eSuitable for process automation integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eDPC3K2A\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e Digital Combination pH\/ORP Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e Online pH and ORP Analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 - 14 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Application Range:\u003c\/strong\u003e 2.5 - 12.5 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1 pH under reference conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode Material:\u003c\/strong\u003e General Purpose Glass Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e 316 Stainless Steel \/ PVDF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted Materials:\u003c\/strong\u003e 316SS, PVDF, PTFE, Glass, FKM\/FPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e Pt1000 Ohm RTD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 105°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e 0 - 6.9 bar at 100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pressure:\u003c\/strong\u003e 100 psig at 212°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Cable:\u003c\/strong\u003e 4.5 m integrated coaxial cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Thread:\u003c\/strong\u003e 0.75 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Distance:\u003c\/strong\u003e Up to 1000 m with Hach Digital Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Interface:\u003c\/strong\u003e Digital process transmission\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Industrial corrosion-resistant design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Style:\u003c\/strong\u003e Inline or immersion mounting support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eHACH DPC3K2A\u003c\/span\u003e\u003c\/strong\u003e sensor\u003c\/li\u003e\n\u003cli\u003e15 ft integrated sensor cable\u003c\/li\u003e\n\u003cli\u003eDigital gateway module\u003c\/li\u003e\n\u003cli\u003e3 ft digital extension cable\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial System Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eDPC3K2A\u003c\/span\u003e\u003c\/strong\u003e integrates efficiently with industrial water quality control systems.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompatible with Hach sc series controllers\u003c\/li\u003e\n\u003cli\u003eSupports digital gateway architectures\u003c\/li\u003e\n\u003cli\u003eSuitable for online process analyzers\u003c\/li\u003e\n\u003cli\u003eSupports wastewater treatment instrumentation\u003c\/li\u003e\n\u003cli\u003eCompatible with industrial PLC monitoring systems\u003c\/li\u003e\n\u003cli\u003eSuitable for remote monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Application Environments\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMunicipal water treatment facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater processing plants\u003c\/li\u003e\n\u003cli\u003eChemical production systems\u003c\/li\u003e\n\u003cli\u003eFood and beverage process monitoring\u003c\/li\u003e\n\u003cli\u003eBoiler water treatment systems\u003c\/li\u003e\n\u003cli\u003ePharmaceutical water quality control\u003c\/li\u003e\n\u003cli\u003eSurface water environmental monitoring\u003c\/li\u003e\n\u003cli\u003eCooling tower process supervision\u003c\/li\u003e\n\u003cli\u003eIndustrial neutralization systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOperational Diagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eHACH DPC3K2A\u003c\/span\u003e\u003c\/strong\u003e supports stable process diagnostics during continuous operation.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eImproves abnormal signal detection capability\u003c\/li\u003e\n\u003cli\u003eSupports process calibration verification\u003c\/li\u003e\n\u003cli\u003eEnhances long-distance communication stability\u003c\/li\u003e\n\u003cli\u003eReduces signal interference risks\u003c\/li\u003e\n\u003cli\u003eSupports preventive maintenance strategies\u003c\/li\u003e\n\u003cli\u003eImproves troubleshooting response efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0b5cad;\"\u003eDPC3K2A\u003c\/span\u003e\u003c\/strong\u003e performs reliably in industrial pH monitoring applications requiring stable long-distance communication.\u003c\/p\u003e\n\n\u003cp\u003eThe Pt1000 compensation structure improves temperature-related measurement consistency.\u003c\/p\u003e\n\n\u003cp\u003eEngineers prefer the stainless steel and PVDF construction for chemically demanding environments.\u003c\/p\u003e\n\n\u003cp\u003eThe digital architecture simplifies integration with centralized process control platforms.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor suits facilities prioritizing continuous online water quality supervision.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation and Engineering Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall away from heavy electrical interference sources\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding for stable signal performance\u003c\/li\u003e\n\u003cli\u003eInspect electrode surfaces during scheduled maintenance\u003c\/li\u003e\n\u003cli\u003eCalibrate regularly for critical process applications\u003c\/li\u003e\n\u003cli\u003eUse compatible mounting hardware for pressure stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial Logistics and Warranty Service\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty support included\u003c\/li\u003e\n\u003cli\u003eTechnical inspection completed before shipment\u003c\/li\u003e\n\u003cli\u003eFedEx international delivery available\u003c\/li\u003e\n\u003cli\u003eUPS expedited shipping supported\u003c\/li\u003e\n\u003cli\u003eDHL global logistics service available\u003c\/li\u003e\n\u003cli\u003eProtective export packaging included\u003c\/li\u003e\n\u003cli\u003eFast order processing for urgent projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich installation method improves measurement stability most effectively?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInline mounting with stable flow conditions improves process consistency significantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Pt1000 compensator improve process accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe compensator corrects temperature influence during dynamic process fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat factors shorten electrode service life in industrial applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh contamination, coating buildup, and improper cleaning reduce electrode performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should engineers select compatible process controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelect controllers supporting digital gateway communication and required transmission distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is digital transmission preferred in large treatment facilities?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDigital communication improves signal integrity over extended cable distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109425209526,"sku":"DPC3K2A","price":389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DPC3K2A.jpg?v=1778133788"},{"product_id":"dpc2k2a-hach-combination-ph-orp-sensor-high-stability-digital-electrode","title":"DPC2K2A HACH Combination pH ORP Sensor High Stability Digital Electrode","description":"\u003ch3\u003e\u003cstrong\u003eIndustrial Water Analysis Platform – \u003cspan style=\"color:#c00000;\"\u003e\u003cstrong\u003eDPC2K2A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eDPC2K2A\u003c\/span\u003e\u003c\/strong\u003e digital combination pH\/ORP sensor supports stable liquid analysis in industrial environments.  \nIts integrated digital architecture improves signal reliability during continuous operation.  \nThe sensor combines pH measurement, ORP capability, and temperature compensation into one compact assembly.  \nIt is optimized for demanding water treatment and chemical process applications.  \n\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMeasurement \u0026amp; Control Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement range covers 0 to 14 pH\u003c\/li\u003e\n\u003cli\u003eMaintains 0.1 pH accuracy under reference conditions\u003c\/li\u003e\n\u003cli\u003eSupports stable ORP process monitoring\u003c\/li\u003e\n\u003cli\u003eIntegrated Pt1000 RTD improves thermal compensation accuracy\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous online analytical control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSensor Construction Technology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePVDF housing resists aggressive chemical environments\u003c\/li\u003e\n\u003cli\u003eFlat glass electrode improves process contact stability\u003c\/li\u003e\n\u003cli\u003eDouble junction structure reduces contamination influence\u003c\/li\u003e\n\u003cli\u003eFKM\/FPM sealing materials improve chemical resistance\u003c\/li\u003e\n\u003cli\u003eCompact industrial design simplifies field integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTransmission \u0026amp; Integration Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports signal transmission distances up to 1000 meters\u003c\/li\u003e\n\u003cli\u003eCompatible with Hach Digital Gateway systems\u003c\/li\u003e\n\u003cli\u003eWorks with sc100 controllers and termination modules\u003c\/li\u003e\n\u003cli\u003eIntegral coaxial cable improves communication reliability\u003c\/li\u003e\n\u003cli\u003eDigital architecture minimizes signal degradation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOperational Endurance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperates continuously from 0°C to 105°C\u003c\/li\u003e\n\u003cli\u003eHandles process pressure up to 6.9 bar at 100°C\u003c\/li\u003e\n\u003cli\u003eSuitable for demanding industrial fluid systems\u003c\/li\u003e\n\u003cli\u003eStable performance under fluctuating process conditions\u003c\/li\u003e\n\u003cli\u003eSupports long-term process automation applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eDPC2K2A\u003c\/span\u003e\u003c\/strong\u003e digital pH\/ORP sensor\u003c\/li\u003e\n\u003cli\u003e4.5 m integrated sensor cable\u003c\/li\u003e\n\u003cli\u003eDigital gateway module\u003c\/li\u003e\n\u003cli\u003e3 ft digital extension cable\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial wastewater treatment systems\u003c\/li\u003e\n\u003cli\u003eBoiler and cooling water chemistry control\u003c\/li\u003e\n\u003cli\u003eChemical processing plants\u003c\/li\u003e\n\u003cli\u003ePharmaceutical water systems\u003c\/li\u003e\n\u003cli\u003eFood and beverage process monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdentifies abnormal pH fluctuations quickly\u003c\/li\u003e\n\u003cli\u003eImproves process consistency during continuous operation\u003c\/li\u003e\n\u003cli\u003eSupports early detection of chemical imbalance conditions\u003c\/li\u003e\n\u003cli\u003eEnhances remote monitoring system stability\u003c\/li\u003e\n\u003cli\u003eReduces maintenance interruptions through digital diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eDPC2K2A\u003c\/span\u003e\u003c\/strong\u003e performs reliably in high-demand analytical systems\u003c\/li\u003e\n\u003cli\u003eIts digital signal structure improves long-distance communication\u003c\/li\u003e\n\u003cli\u003eSuitable for facilities requiring stable online water analysis\u003c\/li\u003e\n\u003cli\u003eExcellent choice for centralized industrial monitoring networks\u003c\/li\u003e\n\u003cli\u003eRecommended for applications requiring low signal interference\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Warranty Service\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-month warranty\u003c\/strong\u003e included\u003c\/li\u003e\n\u003cli\u003eCourier support via FedEx, UPS and DHL\u003c\/li\u003e\n\u003cli\u003eProtective export-grade packaging\u003c\/li\u003e\n\u003cli\u003eFast dispatch within 24–48 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhy choose a digital sensor over analog models?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDigital transmission improves signal integrity over long distances.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eHow to maintain stable measurement performance?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eClean the electrode regularly and avoid coating buildup.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eWhat installation factor affects response time most?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eInsufficient process flow can slow sensor response.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eWhich systems benefit from this sensor architecture?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eLarge distributed monitoring systems with centralized controllers.\u003c\/li\u003e\n\n\u003cli\u003e\u003cstrong\u003eWhat should engineers verify before selecting this model?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eConfirm controller compatibility and chemical process conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109425438902,"sku":"DPC2K2A","price":452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DPC2K2A.jpg?v=1778134085"},{"product_id":"hach-dpc2k1a-combination-ph-orp-sensor-pvdf-analyzer","title":"HACH DPC2K1A Combination pH\/ORP Sensor | PVDF Analyzer","description":"\u003ch3\u003e\u003cstrong\u003eEngineered for Continuous Industrial pH Control\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c62828;\"\u003eHACH DPC2K1A\u003c\/span\u003e\u003c\/strong\u003e delivers stable digital pH measurement for demanding process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor combines chemical durability with dependable long-term measurement stability.\u003c\/p\u003e\n\n\u003cp\u003eIts PVDF structure withstands corrosive media in industrial liquid applications.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated Pt1000 RTD improves temperature-compensated pH accuracy.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c62828;\"\u003eHACH DPC2K1A Series\u003c\/span\u003e\u003c\/strong\u003e supports reliable process monitoring across automation systems.\u003c\/p\u003e\n\n\u003cp\u003eThe coaxial cable structure minimizes external electrical interference.\u003c\/p\u003e\n\n\u003cp\u003eThe double-junction design improves contamination resistance during continuous operation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Process Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eWide pH measurement capability from 0 to 14 pH\u003c\/li\u003e\n\u003cli\u003eStable signal transmission over long industrial distances\u003c\/li\u003e\n\u003cli\u003eHigh-temperature resistance up to 105°C\u003c\/li\u003e\n\u003cli\u003eReliable operation under elevated process pressure\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature compensation functionality\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade chemical resistance performance\u003c\/li\u003e\n\u003cli\u003eLow-maintenance electrode structure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c62828;\"\u003eDPC2K1A\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Digital Combination pH\/ORP Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 - 14 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e 0.1 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode Type:\u003c\/strong\u003e General Purpose Glass pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e PVDF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted Materials:\u003c\/strong\u003e PVDF, PTFE, Glass, FKM\/FPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e Pt1000 RTD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 105°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e 0 - 6.9 bar at 100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e Integral coaxial cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 4.5 m (15 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Connection:\u003c\/strong\u003e 0.75 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Distance:\u003c\/strong\u003e Up to 1000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Stability:\u003c\/strong\u003e Optimized for industrial noise immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Corrosion-resistant construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Response:\u003c\/strong\u003e Fast process adaptation performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c62828;\"\u003eHACH DPC2K1A\u003c\/span\u003e\u003c\/strong\u003e performs effectively in industrial liquid analysis applications.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor suits facilities requiring stable pH trending under variable process conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated Pt1000 element improves compensation accuracy during temperature fluctuations.\u003c\/p\u003e\n\n\u003cp\u003eEngineers value this model for stable communication over extended cable distances.\u003c\/p\u003e\n\n\u003cp\u003eThe PVDF housing supports aggressive chemical environments without rapid degradation.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor works efficiently with distributed water treatment monitoring systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Equipment Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eHACH sc100 controllers\u003c\/li\u003e\n\u003cli\u003eHACH Digital Gateway systems\u003c\/li\u003e\n\u003cli\u003eIndustrial PLC monitoring platforms\u003c\/li\u003e\n\u003cli\u003eWater quality analyzer systems\u003c\/li\u003e\n\u003cli\u003eChemical dosing skids\u003c\/li\u003e\n\u003cli\u003eWastewater automation stations\u003c\/li\u003e\n\u003cli\u003eIndustrial process control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eApplication Environment\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial wastewater treatment\u003c\/li\u003e\n\u003cli\u003eNeutralization process control\u003c\/li\u003e\n\u003cli\u003eCooling water monitoring\u003c\/li\u003e\n\u003cli\u003eChemical manufacturing systems\u003c\/li\u003e\n\u003cli\u003eFood processing liquid analysis\u003c\/li\u003e\n\u003cli\u003eBoiler feedwater monitoring\u003c\/li\u003e\n\u003cli\u003ePharmaceutical liquid process systems\u003c\/li\u003e\n\u003cli\u003eIndustrial recycling facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports continuous pH trend verification\u003c\/li\u003e\n\u003cli\u003eHelps identify unstable chemical dosing conditions\u003c\/li\u003e\n\u003cli\u003eDetects abnormal process fluctuations quickly\u003c\/li\u003e\n\u003cli\u003eImproves preventive maintenance planning\u003c\/li\u003e\n\u003cli\u003eSupports stable process optimization analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#c62828;\"\u003eHACH DPC2K1A\u003c\/span\u003e\u003c\/strong\u003e Sensor\u003c\/li\u003e\n\u003cli\u003e1 × 15 ft integrated sensor cable\u003c\/li\u003e\n\u003cli\u003e1 × Digital gateway\u003c\/li\u003e\n\u003cli\u003e1 × 3 ft digital extension cable\u003c\/li\u003e\n\u003cli\u003e1 × Product manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast international dispatch service\u003c\/li\u003e\n\u003cli\u003eShipping carriers: FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eProfessional export packaging protection\u003c\/li\u003e\n\u003cli\u003eTracking details provided after shipment\u003c\/li\u003e\n\u003cli\u003eIndustrial anti-shock packaging support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty coverage included\u003c\/li\u003e\n\u003cli\u003eTechnical assistance available during warranty period\u003c\/li\u003e\n\u003cli\u003eInspection completed before shipment\u003c\/li\u003e\n\u003cli\u003eProfessional after-sales response support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy does the Pt1000 RTD improve process stability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Pt1000 compensates measurement drift during liquid temperature fluctuations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich installation position improves sensor lifespan?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eInstall the sensor in stable flow zones with minimal trapped air exposure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can users reduce calibration frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMaintain stable chemical concentration and clean the electrode regularly.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should buyers verify before selecting this model?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConfirm process temperature, chemical compatibility, and controller communication requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy do industrial users prefer digital pH sensors over analog models?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDigital sensors improve signal reliability and reduce electrical noise interference.\u003c\/p\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109425602742,"sku":"DPC2K1A","price":412.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DPC2K1A.jpg?v=1778134093"},{"product_id":"dpc1r3a-hach-combination-ph-orp-sensor-digital-process-sensor","title":"DPC1R3A HACH Combination pH\/ORP Sensor | Digital Process Sensor","description":"\u003ch3\u003e\u003cstrong\u003eDPC1R3A HACH Digital Combination pH\/ORP Sensor\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eDPC1R3A\u003c\/span\u003e\u003c\/strong\u003e delivers stable pH monitoring performance for demanding industrial liquid analysis systems.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor integrates HF-resistant glass technology for chemically aggressive process applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eHACH DPC1R3A\u003c\/span\u003e\u003c\/strong\u003e supports continuous online measurement in industrial water treatment environments.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated Pt1000 RTD improves temperature compensation accuracy during process fluctuations.\u003c\/p\u003e\n\n\u003cp\u003eIts digital communication architecture improves signal reliability across long transmission distances.\u003c\/p\u003e\n\n\u003cp\u003eThe PPS housing enhances durability in industrial operating conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Measurement Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eWide pH measurement capability supports complex industrial processes.\u003c\/li\u003e\n\n\u003cli\u003eHF-resistant electrode structure improves chemical durability.\u003c\/li\u003e\n\n\u003cli\u003eIntegrated temperature compensation increases measurement stability.\u003c\/li\u003e\n\n\u003cli\u003eDigital gateway compatibility supports distributed installations.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial coaxial cable improves signal integrity.\u003c\/li\u003e\n\n\u003cli\u003eLong-distance transmission simplifies centralized monitoring layouts.\u003c\/li\u003e\n\n\u003cli\u003ePPS construction improves resistance to harsh process environments.\u003c\/li\u003e\n\n\u003cli\u003eStable electrochemical response supports continuous online analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eHACH\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eDPC1R3A\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Combination pH\/ORP Sensor\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 14 pH\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0.1 pH under reference conditions\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eElectrode Material:\u003c\/strong\u003e HF-Resistant Glass\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e PPS\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 105°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e 0 to 6.9 bar at 100°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e Pt1000 ohm RTD\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSensor Thread:\u003c\/strong\u003e 0.75 inch\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSensor Cable:\u003c\/strong\u003e Integral coaxial cable\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 4.5 m (15 ft.)\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eTransmission Distance:\u003c\/strong\u003e Up to 1000 m\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eRecommended Process Range:\u003c\/strong\u003e pH 2.5 to 12.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eDPC1R3A\u003c\/span\u003e\u003c\/strong\u003e sensor with 15 ft cable\u003c\/li\u003e\n\n\u003cli\u003e1 × Digital Gateway\u003c\/li\u003e\n\n\u003cli\u003e1 × 3 ft digital extension cable\u003c\/li\u003e\n\n\u003cli\u003e1 × Product manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatible Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eHACH sc100 controller systems\u003c\/li\u003e\n\n\u003cli\u003eIndustrial pH analyzer platforms\u003c\/li\u003e\n\n\u003cli\u003eChemical dosing control skids\u003c\/li\u003e\n\n\u003cli\u003eUltra pure water monitoring systems\u003c\/li\u003e\n\n\u003cli\u003eWastewater treatment automation systems\u003c\/li\u003e\n\n\u003cli\u003eIndustrial process monitoring cabinets\u003c\/li\u003e\n\n\u003cli\u003eSemiconductor water treatment equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eAcid and alkali process monitoring\u003c\/li\u003e\n\n\u003cli\u003eIndustrial wastewater neutralization systems\u003c\/li\u003e\n\n\u003cli\u003eSemiconductor rinse water treatment\u003c\/li\u003e\n\n\u003cli\u003eChemical production process control\u003c\/li\u003e\n\n\u003cli\u003ePower plant water chemistry analysis\u003c\/li\u003e\n\n\u003cli\u003eContinuous online pH regulation systems\u003c\/li\u003e\n\n\u003cli\u003eCorrosive process liquid monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic And Monitoring Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIntegrated temperature sensing improves compensation accuracy.\u003c\/li\u003e\n\n\u003cli\u003eStable digital communication reduces transmission signal loss.\u003c\/li\u003e\n\n\u003cli\u003eHF-resistant glass improves operational consistency in corrosive media.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial cable design minimizes electrical interference risks.\u003c\/li\u003e\n\n\u003cli\u003eLong transmission architecture supports remote installation layouts.\u003c\/li\u003e\n\n\u003cli\u003eStable process response improves control loop reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eHACH DPC1R3A\u003c\/span\u003e\u003c\/strong\u003e performs effectively in chemically aggressive process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe HF-resistant electrode structure improves service stability in acidic applications.\u003c\/p\u003e\n\n\u003cp\u003eEngineers often deploy this sensor in semiconductor and industrial water systems.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated Pt1000 RTD improves process compensation accuracy significantly.\u003c\/p\u003e\n\n\u003cp\u003eIts digital communication capability supports long-distance analyzer installations.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor suits facilities requiring continuous pH monitoring reliability.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Installation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the sensor in stable flow locations.\u003c\/li\u003e\n\n\u003cli\u003eMaintain proper grounding during commissioning procedures.\u003c\/li\u003e\n\n\u003cli\u003eAvoid excessive cable bending during installation.\u003c\/li\u003e\n\n\u003cli\u003eUse compatible mounting hardware for pressure applications.\u003c\/li\u003e\n\n\u003cli\u003eSchedule routine cleaning to maintain measurement consistency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping And Warranty Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast order processing within 24-48 hours.\u003c\/li\u003e\n\n\u003cli\u003eWorldwide delivery available through FedEx, UPS, and DHL.\u003c\/li\u003e\n\n\u003cli\u003eProtective industrial packaging improves transport safety.\u003c\/li\u003e\n\n\u003cli\u003eExport-ready handling supports international projects.\u003c\/li\u003e\n\n\u003cli\u003e12-month warranty service included.\u003c\/li\u003e\n\n\u003cli\u003eTechnical support available for integration assistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is HF-resistant glass important for industrial pH monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eHF-resistant glass improves durability in chemically aggressive process conditions.\u003c\/p\u003e\n\n\u003cp\u003eIt also reduces electrode degradation risks during continuous operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does Pt1000 compensation improve measurement performance?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIntegrated temperature compensation improves pH stability during thermal fluctuations.\u003c\/p\u003e\n\n\u003cp\u003eThis feature supports more consistent process control results.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich environments benefit most from long transmission capability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eLarge industrial facilities benefit from centralized analyzer cabinet layouts.\u003c\/p\u003e\n\n\u003cp\u003eRemote monitoring systems also gain installation flexibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat maintenance practice improves long-term electrode performance?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eRoutine cleaning prevents coating accumulation on sensing surfaces.\u003c\/p\u003e\n\n\u003cp\u003eStable calibration intervals also improve operational consistency.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow should engineers select pH sensors for corrosive applications?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eReview chemical compatibility, operating temperature, and pressure requirements carefully.\u003c\/p\u003e\n\n\u003cp\u003eHF-resistant electrode materials suit aggressive liquid environments effectively.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eChoose \u003cstrong\u003e\u003cspan style=\"color:#006699;\"\u003eDPC1R3A\u003c\/span\u003e\u003c\/strong\u003e for corrosive process monitoring applications.\u003c\/li\u003e\n\n\u003cli\u003eSelect this sensor for continuous industrial pH analysis systems.\u003c\/li\u003e\n\n\u003cli\u003eUse digital communication architecture for remote installations.\u003c\/li\u003e\n\n\u003cli\u003eChoose Pt1000 compensation for temperature-sensitive applications.\u003c\/li\u003e\n\n\u003cli\u003eVerify process pressure compatibility before deployment.\u003c\/li\u003e\n\n\u003cli\u003eConsider HF-resistant electrodes for aggressive chemical environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109426290870,"sku":"DPC1R3A","price":418.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DPC1R3A.jpg?v=1778134101"},{"product_id":"dpc1r2a-hach-combination-ph-orp-sensor-industrial-digital-analyzer-probe","title":"DPC1R2A HACH Combination pH ORP Sensor Industrial Digital Analyzer Probe","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eDPC1R2A\u003c\/span\u003e Digital Process pH\/ORP Monitoring Sensor\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eHACH DPC1R2A\u003c\/span\u003e\u003c\/strong\u003e supports stable online pH and ORP measurement for industrial process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe flat glass electrode structure improves performance in contamination-prone applications.\u003c\/p\u003e\n\n\u003cp\u003eThe digital architecture enhances signal reliability across extended transmission distances.\u003c\/p\u003e\n\n\u003cp\u003eThe PPS body material supports demanding chemical and wastewater operating conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eDPC1R2A\u003c\/span\u003e\u003c\/strong\u003e integrates efficiently into modern industrial water analysis systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcess Engineering Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFlat glass electrode design improves fouling resistance\u003c\/li\u003e\n\u003cli\u003eDigital signal transmission supports stable process integration\u003c\/li\u003e\n\u003cli\u003eIntegrated Pt1000 compensation improves thermal accuracy\u003c\/li\u003e\n\u003cli\u003eOptimized for continuous industrial liquid monitoring\u003c\/li\u003e\n\u003cli\u003eSuitable for harsh wastewater process environments\u003c\/li\u003e\n\u003cli\u003eSupports long-distance instrumentation layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for online pH and ORP supervision\u003c\/li\u003e\n\u003cli\u003eSupports reliable industrial automation communication\u003c\/li\u003e\n\u003cli\u003eCompact installation structure simplifies deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Data Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eDPC1R2A\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Digital Combination pH\/ORP Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Function:\u003c\/strong\u003e Continuous pH and ORP analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 - 14 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Operating Range:\u003c\/strong\u003e 2.5 - 12.5 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e ±0.1 pH under reference conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode Type:\u003c\/strong\u003e Flat Glass pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e PPS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e Pt1000 Ohm RTD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 105°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e 0 - 6.9 bar at 100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pressure:\u003c\/strong\u003e 100 psig at 212°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Cable:\u003c\/strong\u003e 4.5 m integrated coaxial cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Thread:\u003c\/strong\u003e 0.75 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Capability:\u003c\/strong\u003e Up to 1000 m signal distance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Support:\u003c\/strong\u003e Digital communication architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Industrial corrosion-resistant structure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Support:\u003c\/strong\u003e Inline and immersion mounting compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eHACH DPC1R2A\u003c\/span\u003e\u003c\/strong\u003e sensor\u003c\/li\u003e\n\u003cli\u003e15 ft integrated sensor cable\u003c\/li\u003e\n\u003cli\u003eDigital gateway module\u003c\/li\u003e\n\u003cli\u003e3 ft digital extension cable\u003c\/li\u003e\n\u003cli\u003eOperation and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatible Equipment Platforms\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eHACH sc100 controller systems\u003c\/li\u003e\n\u003cli\u003eDigital gateway monitoring platforms\u003c\/li\u003e\n\u003cli\u003eIndustrial PLC-based water monitoring systems\u003c\/li\u003e\n\u003cli\u003eOnline wastewater analysis equipment\u003c\/li\u003e\n\u003cli\u003eChemical process control systems\u003c\/li\u003e\n\u003cli\u003eRemote industrial monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial wastewater treatment facilities\u003c\/li\u003e\n\u003cli\u003ePaper and pulp process systems\u003c\/li\u003e\n\u003cli\u003eChemical dosing control platforms\u003c\/li\u003e\n\u003cli\u003eFood processing wastewater supervision\u003c\/li\u003e\n\u003cli\u003eMining water treatment applications\u003c\/li\u003e\n\u003cli\u003eMunicipal environmental monitoring stations\u003c\/li\u003e\n\u003cli\u003eNeutralization process management systems\u003c\/li\u003e\n\u003cli\u003eCooling water circulation monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial discharge compliance systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eAdvanced Diagnostic Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eDPC1R2A\u003c\/span\u003e\u003c\/strong\u003e supports predictive maintenance and process stability analysis.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eImproves coating and contamination detection capability\u003c\/li\u003e\n\u003cli\u003eSupports calibration trend verification\u003c\/li\u003e\n\u003cli\u003eEnhances long-range signal stability monitoring\u003c\/li\u003e\n\u003cli\u003eReduces process interruption risks\u003c\/li\u003e\n\u003cli\u003eSupports rapid maintenance troubleshooting\u003c\/li\u003e\n\u003cli\u003eImproves operational consistency in dynamic environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#0070c0;\"\u003eHACH DPC1R2A\u003c\/span\u003e\u003c\/strong\u003e performs effectively in wastewater applications with elevated contamination exposure.\u003c\/p\u003e\n\n\u003cp\u003eThe flat glass electrode structure simplifies maintenance in difficult process conditions.\u003c\/p\u003e\n\n\u003cp\u003eEngineers frequently select PPS housing for chemically aggressive environments.\u003c\/p\u003e\n\n\u003cp\u003eThe long-distance digital transmission capability benefits distributed industrial systems.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor suits facilities requiring stable continuous online process supervision.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation and Process Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the sensor where process flow remains stable\u003c\/li\u003e\n\u003cli\u003eInspect electrode surfaces during routine maintenance intervals\u003c\/li\u003e\n\u003cli\u003eUse shielded wiring near high-power industrial equipment\u003c\/li\u003e\n\u003cli\u003eVerify grounding continuity before startup commissioning\u003c\/li\u003e\n\u003cli\u003eSchedule calibration according to process contamination levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty and International Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty coverage included\u003c\/li\u003e\n\u003cli\u003eProfessional product inspection before shipment\u003c\/li\u003e\n\u003cli\u003eFedEx global express shipping available\u003c\/li\u003e\n\u003cli\u003eUPS industrial logistics service supported\u003c\/li\u003e\n\u003cli\u003eDHL international delivery available\u003c\/li\u003e\n\u003cli\u003eSecure export packaging included\u003c\/li\u003e\n\u003cli\u003eFast dispatch support for urgent maintenance projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do engineers select flat glass electrodes for wastewater monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlat glass structures resist contamination buildup more effectively than bulb-style electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow can users improve long-term sensor stability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoutine cleaning and scheduled calibration improve operational consistency significantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich environments benefit most from PPS sensor construction?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePPS materials perform reliably in chemically aggressive industrial wastewater applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should engineers evaluate before selecting a digital pH sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReview temperature range, chemical compatibility, pressure conditions, and controller integration requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is long-distance digital transmission important in industrial facilities?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt improves signal integrity across large treatment plants and distributed process systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45109426421942,"sku":"DPC1R2A","price":358.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DPC1R2A.jpg?v=1778134109"},{"product_id":"hach-lxv404-99-00502-sc200-universal-controller-digital-input","title":"HACH LXV404.99.00502 SC200 Universal Controller Digital Input","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHACH LXV404.99.00502\u003c\/span\u003e\u003c\/strong\u003e belongs to the advanced \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSC200 Universal Controller Series\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis controller supports stable industrial water analysis and process automation applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit provides one digital sensor input and two isolated 4-20 mA outputs.\u003c\/p\u003e\n\n\u003cp\u003eIt supports flexible installation for wall, pole, or panel mounting environments.\u003c\/p\u003e\n\n\u003cp\u003eThe controller operates with excellent reliability under demanding industrial conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSC200\u003c\/span\u003e\u003c\/strong\u003e offers intuitive operation through a graphic LCD interface with LED backlighting.\u003c\/p\u003e\n\n\u003cp\u003eThe enclosure meets \u003cstrong\u003eNEMA 4X\/IP66\u003c\/strong\u003e protection standards for harsh environments.\u003c\/p\u003e\n\n\u003cp\u003eThis controller supports measurement monitoring, calculated values, relay control, and PID functions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHACH SC200 Series\u003c\/span\u003e\u003c\/strong\u003e controllers provide dependable process control for industrial liquid analysis systems.\u003c\/p\u003e\n\n\u003cp\u003eThe platform supports scalable sensor integration and stable signal transmission.\u003c\/p\u003e\n\n\u003cp\u003eEngineers prefer this series for reliable communication and flexible analog output configuration.\u003c\/p\u003e\n\n\u003cp\u003eThe controller performs well in municipal water treatment and industrial wastewater applications.\u003c\/p\u003e\n\n\u003cp\u003eIts compact design simplifies retrofit projects and control cabinet integration.\u003c\/p\u003e\n\n\u003cp\u003eThe system supports continuous operation with minimal maintenance requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHACH\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eLXV404.99.00502\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSC200 Universal Controller\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne digital sensor input configuration\u003c\/li\u003e\n\u003cli\u003eTwo isolated 4-20 mA analog outputs\u003c\/li\u003e\n\u003cli\u003eSupports optional expansion module configuration\u003c\/li\u003e\n\u003cli\u003eGraphic LCD display with LED backlighting\u003c\/li\u003e\n\u003cli\u003eLinear, logarithmic, bi-linear, and PID output modes\u003c\/li\u003e\n\u003cli\u003eDual password-protected security levels\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade NEMA 4X\/IP66 enclosure\u003c\/li\u003e\n\u003cli\u003eFlexible wall, pole, and panel installation options\u003c\/li\u003e\n\u003cli\u003eReliable relay operation for process automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHACH\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eLXV404.99.00502\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSC200\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e One digital sensor input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e Two isolated 4-20 mA outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Expansion:\u003c\/strong\u003e Up to five analog outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Accuracy:\u003c\/strong\u003e ±0.1% FS at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Accuracy Range:\u003c\/strong\u003e ±0.5% FS from -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e Maximum 550 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 V AC or 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 50 VA with 7 W probe load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power Consumption:\u003c\/strong\u003e 100 VA with 28 W probe load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output:\u003c\/strong\u003e 240 VAC, 5 AMP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Type:\u003c\/strong\u003e Graphic dot matrix LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Resolution:\u003c\/strong\u003e 240 × 160 pixels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Size:\u003c\/strong\u003e 48 mm × 68 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Modes:\u003c\/strong\u003e Measurement or calculated values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Modes:\u003c\/strong\u003e Linear, Logarithmic, Bi-linear, PID\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Resistance:\u003c\/strong\u003e 0 to 95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e NEMA 4X\/IP66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Resistance:\u003c\/strong\u003e Industrial isolated signal architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Openings:\u003c\/strong\u003e 1\/2 inch NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 144 mm × 144 mm × 181 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.70 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the controller in dry and vibration-controlled environments.\u003c\/li\u003e\n\u003cli\u003eEnsure stable grounding for improved signal integrity.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient airflow around the enclosure.\u003c\/li\u003e\n\u003cli\u003eUse compatible conduit fittings for cable protection.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage before system energization.\u003c\/li\u003e\n\u003cli\u003eFollow local electrical safety regulations during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance Convenience\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe graphical display simplifies configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003ePassword protection improves operational security.\u003c\/li\u003e\n\u003cli\u003eFront-access controls reduce commissioning time.\u003c\/li\u003e\n\u003cli\u003eIsolated outputs improve troubleshooting efficiency.\u003c\/li\u003e\n\u003cli\u003eLED backlighting improves visibility in low-light areas.\u003c\/li\u003e\n\u003cli\u003eModular output expansion supports future upgrades.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatibility Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompatible with supported HACH digital analytical sensors.\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial PLC and SCADA integration.\u003c\/li\u003e\n\u003cli\u003eSupports standard 4-20 mA process communication.\u003c\/li\u003e\n\u003cli\u003eWorks with water treatment and chemical dosing systems.\u003c\/li\u003e\n\u003cli\u003eSupports municipal and industrial automation platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eContinuous process monitoring support\u003c\/li\u003e\n\u003cli\u003eRelay alarm indication functions\u003c\/li\u003e\n\u003cli\u003eSensor signal integrity monitoring\u003c\/li\u003e\n\u003cli\u003eStable analog output verification\u003c\/li\u003e\n\u003cli\u003eQuick fault identification through display interface\u003c\/li\u003e\n\u003cli\u003ePassword-controlled configuration protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMunicipal water treatment systems\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater monitoring\u003c\/li\u003e\n\u003cli\u003eChemical processing automation\u003c\/li\u003e\n\u003cli\u003eBoiler water analysis systems\u003c\/li\u003e\n\u003cli\u003eCooling tower monitoring\u003c\/li\u003e\n\u003cli\u003eFood and beverage process control\u003c\/li\u003e\n\u003cli\u003ePharmaceutical water systems\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertification Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eNEMA 4X enclosure compliance\u003c\/li\u003e\n\u003cli\u003eIP66 environmental protection rating\u003c\/li\u003e\n\u003cli\u003eIndustrial automation application suitability\u003c\/li\u003e\n\u003cli\u003eDesigned for demanding process environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHACH LXV404.99.00502 SC200 Controller\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 × User documentation set\u003c\/li\u003e\n\u003cli\u003e1 × Standard installation accessories package\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast shipment within 24-48 hours\u003c\/li\u003e\n\u003cli\u003eWorldwide delivery available\u003c\/li\u003e\n\u003cli\u003eShipping carriers include FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eProtective industrial export packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty coverage\u003c\/li\u003e\n\u003cli\u003eTechnical support available during warranty period\u003c\/li\u003e\n\u003cli\u003eProfessional after-sales assistance provided\u003c\/li\u003e\n\u003cli\u003eWarranty covers standard operational defects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat industries commonly use the SC200 controller?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWater treatment, chemical processing, and environmental monitoring industries frequently use this controller.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this controller connect with PLC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The isolated 4-20 mA outputs support standard PLC integration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes the controller support outdoor installation?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The NEMA 4X\/IP66 enclosure supports demanding industrial environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should engineers verify before installation?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eEngineers should verify voltage compatibility, grounding quality, and sensor communication requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can users improve long-term operational stability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eRegular inspection of wiring connections and environmental sealing improves stability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the display suitable for low-light control rooms?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The LED backlit LCD improves readability in industrial environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat advantages does isolated analog output provide?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIsolation improves signal reliability and reduces electrical interference risks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow should users select compatible sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eSelect HACH-compatible digital sensors matching measurement and communication requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan the controller support future system expansion?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. Optional modules allow additional analog output expansion.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich installation method suits compact control cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePanel mounting provides efficient space utilization for compact industrial cabinets.\u003c\/p\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45138151375030,"sku":"LXV404.99.00502","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/LXV404.99.00502.jpg?v=1779438103"},{"product_id":"hach-lxv404-99-00102-sc200-universal-controller-for-ph-orp-do","title":"HACH LXV404.99.00102 SC200 Universal Controller for pH ORP DO","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eHACH LXV404.99.00102\u003c\/span\u003e\u003c\/strong\u003e belongs to the advanced \u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eSC200 Universal Controller\u003c\/span\u003e\u003c\/strong\u003e series.\u003c\/p\u003e\n\n\u003cp\u003eThis controller supports reliable water analysis and process monitoring applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit provides stable analog signal processing for industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eIt supports one analog sensor input for pH, ORP, or dissolved oxygen measurement.\u003c\/p\u003e\n\n\u003cp\u003eDual 4-20 mA outputs simplify integration with PLC and DCS systems.\u003c\/p\u003e\n\n\u003cp\u003eThe controller operates with 100-240 VAC universal power input.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eLXV404.99.00102\u003c\/span\u003e\u003c\/strong\u003e offers dependable performance in municipal and industrial automation systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eHACH SC200 Series\u003c\/span\u003e\u003c\/strong\u003e controllers focus on flexible sensor management and stable analog communication.\u003c\/p\u003e\n\n\u003cp\u003eThe architecture supports continuous process monitoring with low maintenance requirements.\u003c\/p\u003e\n\n\u003cp\u003eThe controller suits demanding environments with electrical interference and variable operating conditions.\u003c\/p\u003e\n\n\u003cp\u003eEngineers prefer this series for water treatment, chemical dosing, and utility monitoring systems.\u003c\/p\u003e\n\n\u003cp\u003eThe compact enclosure simplifies installation inside control cabinets.\u003c\/p\u003e\n\n\u003cp\u003eThe dual 4-20 mA outputs improve compatibility with legacy automation platforms.\u003c\/p\u003e\n\n\u003cp\u003eThis controller works effectively with:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial PLC systems\u003c\/li\u003e\n\u003cli\u003eDCS process control platforms\u003c\/li\u003e\n\u003cli\u003eWater treatment skids\u003c\/li\u003e\n\u003cli\u003eChemical dosing systems\u003c\/li\u003e\n\u003cli\u003eBoiler monitoring equipment\u003c\/li\u003e\n\u003cli\u003eCooling water management systems\u003c\/li\u003e\n\u003cli\u003eWastewater treatment equipment\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HACH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eLXV404.99.00102\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eSC200 Universal Controller\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Universal Analytical Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100-240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 50 VA with 7 W probe load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 100 VA with 28 W probe load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Input:\u003c\/strong\u003e One analog pH\/ORP\/DO input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e Two isolated 4-20 mA outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output:\u003c\/strong\u003e 240 VAC, 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Type:\u003c\/strong\u003e Analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e High-resolution analog signal processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Stable linear signal transmission\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Optimized for low-noise sensor acquisition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Suitable for continuous process monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Suitable for industrial indoor environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Resistant to industrial electrical interference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Immunity:\u003c\/strong\u003e Designed for stable operation near automation equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 18.1 cm × 14.4 cm × 14.4 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.7 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eSC200\u003c\/span\u003e\u003c\/strong\u003e supports accurate water quality monitoring.\u003c\/li\u003e\n\u003cli\u003eThe controller enables fast integration with existing control systems.\u003c\/li\u003e\n\u003cli\u003eDual analog outputs support remote monitoring applications.\u003c\/li\u003e\n\u003cli\u003eThe compact structure saves cabinet installation space.\u003c\/li\u003e\n\u003cli\u003eThe interface simplifies parameter configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003eThe controller maintains stable performance during continuous operation.\u003c\/li\u003e\n\u003cli\u003eUniversal power input supports global industrial standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the controller inside a dry industrial control cabinet.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding for signal stability.\u003c\/li\u003e\n\u003cli\u003eSeparate analog cables from high-voltage wiring.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for sensor connections.\u003c\/li\u003e\n\u003cli\u003eAllow sufficient ventilation around the enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify power voltage before startup.\u003c\/li\u003e\n\u003cli\u003eFollow terminal labeling during wiring installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe menu structure supports quick startup procedures.\u003c\/li\u003e\n\u003cli\u003eSensor calibration requires minimal configuration steps.\u003c\/li\u003e\n\u003cli\u003eLED and display indicators simplify operational verification.\u003c\/li\u003e\n\u003cli\u003eThe controller supports rapid signal troubleshooting.\u003c\/li\u003e\n\u003cli\u003eRoutine maintenance mainly includes terminal inspection and sensor cleaning.\u003c\/li\u003e\n\u003cli\u003eThe modular design reduces maintenance downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatibility Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompatible with analog pH sensors.\u003c\/li\u003e\n\u003cli\u003eCompatible with ORP monitoring probes.\u003c\/li\u003e\n\u003cli\u003eCompatible with dissolved oxygen transmitters.\u003c\/li\u003e\n\u003cli\u003eSupports integration with PLC and SCADA systems.\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial water treatment applications.\u003c\/li\u003e\n\u003cli\u003eSuitable for environmental monitoring installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe controller monitors analog signal stability continuously.\u003c\/li\u003e\n\u003cli\u003eBuilt-in diagnostics assist sensor fault identification.\u003c\/li\u003e\n\u003cli\u003eOutput verification improves process reliability.\u003c\/li\u003e\n\u003cli\u003eStatus indicators simplify maintenance inspection.\u003c\/li\u003e\n\u003cli\u003eError monitoring reduces unexpected process interruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMunicipal water treatment plants\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater treatment systems\u003c\/li\u003e\n\u003cli\u003ePower generation facilities\u003c\/li\u003e\n\u003cli\u003eChemical processing plants\u003c\/li\u003e\n\u003cli\u003eFood and beverage production lines\u003c\/li\u003e\n\u003cli\u003eCooling tower monitoring systems\u003c\/li\u003e\n\u003cli\u003eBoiler feedwater analysis systems\u003c\/li\u003e\n\u003cli\u003eEnvironmental compliance monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertification Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDesigned according to industrial automation standards.\u003c\/li\u003e\n\u003cli\u003eSupports industrial electrical safety requirements.\u003c\/li\u003e\n\u003cli\u003eSuitable for international industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eHACH LXV404.99.00102\u003c\/span\u003e\u003c\/strong\u003e Controller\u003c\/li\u003e\n\u003cli\u003eFactory identification label\u003c\/li\u003e\n\u003cli\u003eTerminal connection documentation\u003c\/li\u003e\n\u003cli\u003eProtective industrial packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty included.\u003c\/li\u003e\n\u003cli\u003eProfessional anti-static packaging provided.\u003c\/li\u003e\n\u003cli\u003eFedEx shipping available.\u003c\/li\u003e\n\u003cli\u003eUPS shipping available.\u003c\/li\u003e\n\u003cli\u003eDHL shipping available.\u003c\/li\u003e\n\u003cli\u003eOrders ship within 24-48 hours.\u003c\/li\u003e\n\u003cli\u003eGlobal export support available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat sensors work with the SC200 controller?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe controller supports analog pH, ORP, and dissolved oxygen sensors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this controller connect to a PLC system?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The dual 4-20 mA outputs support most PLC and DCS platforms.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes the controller support industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The design supports stable operation in industrial automation systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat power input does the controller require?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe unit operates with 100-240 VAC power input.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can engineers reduce analog signal interference?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse shielded cables and separate signal wiring from power cables.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich applications commonly use this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWater treatment, chemical processing, and environmental monitoring applications use this controller frequently.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow should users select compatible sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eSelect analog pH, ORP, or DO sensors matching the process measurement range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat installation practice improves long-term stability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eProper grounding and stable cabinet ventilation improve operational reliability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy do automation engineers prefer the SC200 series?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe series combines flexible sensor support with dependable analog communication.\u003c\/p\u003e","brand":"HACH","offers":[{"title":"Default Title","offer_id":45138167333046,"sku":"LXV404.99.00102","price":147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/LXV404.99.00102.jpg?v=1779438115"}],"url":"https:\/\/www.plcsparehub.com\/collections\/hach.oembed","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}