{"product_id":"tcsesm043f23f0-schneider-electric-connexium-managed-switch","title":"TCSESM043F23F0 Schneider Electric ConneXium Managed Switch","description":"\u003ch3\u003eProduct Architecture and Core Identity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e functions as a high-reliability industrial managed Ethernet switch engineered within the \u003cstrong\u003eConneXium\u003c\/strong\u003e series by \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e. Built on a Transparent Ready concept, the device provides robust \u003cstrong\u003eEthernet TCP\/IP\u003c\/strong\u003e communication across harsh factory automation floors. It features 4 dedicated copper ports supporting 10BASE-T\/100BASE-TX transmission speeds via shielded RJ45 interfaces.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003ePerformance Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConneXium\u003c\/strong\u003e Managed Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ports for copper (Shielded RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT 5E twisted shielded pairs cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V (Limits: 18...30 V AC SELV, 9.6...60 V DC SELV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy \u0026amp; Ring Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant power supplies, single ring, RSTP (Max 50 switches in ring; unlimited in cascade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure \u0026amp; Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 protection, 35 mm symmetrical DIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWidth: 47 mm, Height: 131 mm, Depth: 111 mm, Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 °C temperature, 10...95% relative humidity (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Resiliency Deployment: During a recent SCADA network upgrade for a municipal water treatment plant, our engineering team utilized the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e to anchor a localized RSTP ring. The dual 24V DC power feed integration prevented packet drops during sudden auxiliary power switches, while the web-server configuration interface allowed real-time port priority mapping without proprietary software overhead.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Signalling: Field technicians should monitor the dedicated local LEDs (fault, P1\/P2 power, ring manager, stand-by, and per-channel activity) to instantly isolate physical link drops or power supply fluctuations on the DIN rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Industrial Equipment and Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete manufacturing cell controllers requiring determinism and high-speed data stream management via IGMP Snooping.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment remote telemetry units (RTUs) demanding redundant power supply arrangements.\u003c\/li\u003e\n\u003cli\u003eEnergy and power distribution sub-stations operating in environments requiring Class 1 Division 2 hazardous certifications.\u003c\/li\u003e\n\u003cli\u003eMaterial handling conveyor networks utilizing rapid spanning tree protocols to eliminate single points of network failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a 1 A volt-free contact alarm output to immediately signal power supply faults, switch failures, data link drops, or redundancy ring breaks to main PLCs.\u003c\/li\u003e\n\u003cli\u003eSupports comprehensive data stream controls including FDR (Fast Device Replacement), IGMP Snooping, Multicast filtering, and VLAN structuring.\u003c\/li\u003e\n\u003cli\u003eSecure port features restrict unauthorized physical access at the switch edge, safeguarding critical industrial control systems from spoofing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Warranty, and Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Carriers\u003c\/strong\u003e: Rapid global dispatch handled via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Window\u003c\/strong\u003e: Guaranteed shipping within 24 to 48 hours of order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Assurance\u003c\/strong\u003e: Supplied strictly as brand new and original in factory packaging, backed by a comprehensive 12-month quality warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eHow does the FDR feature on the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e streamline field maintenance?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eFast Device Replacement (FDR) allows an automated DHCP\/TFTP server configuration backup scheme, meaning a replaced switch automatically downloads its exact parameter set without manual programming.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eWhat wiring medium is strictly recommended for maintaining EMI immunity with the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eCAT 5E twisted shielded pairs cable must be used alongside proper panel grounding to suppress high-frequency electrical noise typical in heavy industrial switchyards.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eCan the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e operate under wide DC voltage swings?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eYes, its isolated SELV input safely tolerates wide DC supply voltage boundaries ranging from 9.6 V DC up to 60 V DC.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eWhat hazardous location approvals are associated with the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eTCSESM043F23F0\u003c\/span\u003e\u003c\/strong\u003e?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eThe unit carries UL 1604 Class 1 Division 2 and CSA C22.2 No 213 Class I Division 2 ratings, making it certified for explosive gas atmospheres.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eHow many switches can be linked together in a redundant ring topology using this model?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eThe architecture safely supports up to 50 switches in a single redundancy ring while allowing an unlimited cascade count for linear branches.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TCSESM043F23F0.png?v=1786088763\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45331431358646,"sku":"TCSESM043F23F0","price":109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TCSESM043F23F0.jpg?v=1786088752","url":"https:\/\/www.plcsparehub.com\/ar\/products\/tcsesm043f23f0-schneider-electric-connexium-managed-switch","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}