{"product_id":"rgs20-s-renishaw-incremental-optical-scale-quantic-rgh-systems","title":"RGS20-S Renishaw Incremental Optical Scale | QUANTiC \u0026 RGH Systems","description":"\u003ch3\u003e\u003cb\u003e01. Product Profile | Precision Linear Scale\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #b8860b;\"\u003eRenishaw RGS20-S\u003c\/span\u003e\u003c\/strong\u003e is a gold-plated steel incremental optical scale for precision linear measurement systems. It uses a reflective optical grating with a 20 µm pitch. The flexible steel construction supports direct installation on precision machine structures. The scale provides incremental position information through compatible Renishaw optical readheads. Its thin profile supports applications with limited mounting space. The adhesive backing simplifies installation. End clamps and structural bonding help maintain stable scale positioning during thermal changes. \u003cstrong\u003ePrimary Engineering Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncremental optical position measurement.\u003c\/li\u003e\n\u003cli\u003eHigh-precision linear motion feedback.\u003c\/li\u003e\n\u003cli\u003eReflective optical scale construction.\u003c\/li\u003e\n\u003cli\u003eDirect mounting on compatible machine substrates.\u003c\/li\u003e\n\u003cli\u003eThermal expansion matching with the mounting structure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e02. Scale Construction | Material and Layer Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS20-S uses a flexible multilayer construction. Each layer serves a specific mechanical or optical function.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial \/ Structure\u003c\/th\u003e\n\u003cth\u003eEngineering Purpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Surface\u003c\/td\u003e\n\u003ctd\u003eGold-plated reflective surface\u003c\/td\u003e\n\u003ctd\u003eProvides the reflective optical reading surface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Substrate\u003c\/td\u003e\n\u003ctd\u003eFlexible steel strip\u003c\/td\u003e\n\u003ctd\u003eProvides mechanical support and dimensional stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Layer\u003c\/td\u003e\n\u003ctd\u003eProtective lacquer coating\u003c\/td\u003e\n\u003ctd\u003eProtects the optical surface during normal service.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Layer\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing\u003c\/td\u003e\n\u003ctd\u003eSupports direct installation on prepared substrates.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd Fixing\u003c\/td\u003e\n\u003ctd\u003eEnd clamps with two-part epoxy adhesive\u003c\/td\u003e\n\u003ctd\u003eSecures the scale ends during installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Selection Advantage:\u003c\/strong\u003e The reflective gold-plated surface supports optical measurement. The flexible steel substrate follows the thermal behavior of its mounting structure when correctly installed.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03. Technical Data | Dimensional and Optical Parameters\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS20-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReflective Incremental Optical Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Technology\u003c\/td\u003e\n\u003ctd\u003eGold-plated steel grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e20 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±3 µm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Range Linearity\u003c\/td\u003e\n\u003ctd\u003e±0.75 µm over 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Width\u003c\/td\u003e\n\u003ctd\u003eApproximately 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThickness\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.15–0.2 mm, including adhesive backing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Length\u003c\/td\u003e\n\u003ctd\u003eApplication-dependent; commonly supplied from 100 mm to 50 m or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive backing with end fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Material\u003c\/td\u003e\n\u003ctd\u003eFlexible steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification Note:\u003c\/strong\u003e Confirm the available length, dimensional tolerances and linearity conditions with the applicable Renishaw technical documentation before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04. Thermal Engineering | Substrate Expansion Matching\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS20-S supports direct mounting on different machine substrates. Compatible substrate materials include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMetal machine structures.\u003c\/li\u003e\n\u003cli\u003eGranite measurement platforms.\u003c\/li\u003e\n\u003cli\u003eCeramic structural components.\u003c\/li\u003e\n\u003cli\u003eComposite machine structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Installation Principle\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePrepare and clean the mounting surface.\u003c\/li\u003e\n\u003cli\u003eAlign the scale along the measurement axis.\u003c\/li\u003e\n\u003cli\u003eApply the adhesive-backed scale to the substrate.\u003c\/li\u003e\n\u003cli\u003eSecure both ends with suitable end clamps.\u003c\/li\u003e\n\u003cli\u003eUse the specified two-part epoxy adhesive for end fixing.\u003c\/li\u003e\n\u003cli\u003eAllow the adhesive to cure according to its technical instructions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWhen correctly installed, the scale follows the thermal expansion behavior of its substrate. This arrangement helps reduce differential expansion errors. \u003cstrong\u003eEngineering Consideration:\u003c\/strong\u003e Substrate material, surface preparation and bonding quality affect long-term measurement stability. Avoid mixing incompatible bonding materials.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05. Readhead Compatibility | Optical System Matching\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS20-S is designed for use with compatible Renishaw RGH optical readheads. \u003cstrong\u003eCompatible Readhead Families:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eReadhead Series\u003c\/th\u003e\n\u003cth\u003eSystem Category\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH22\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH24\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH25\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH26\u003c\/td\u003e\n\u003ctd\u003eIncremental optical readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Matching Checklist\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 20 µm scale pitch requirement.\u003c\/li\u003e\n\u003cli\u003eConfirm the readhead supports reflective scale operation.\u003c\/li\u003e\n\u003cli\u003eCheck the specified readhead mounting geometry.\u003c\/li\u003e\n\u003cli\u003eVerify the optical gap and alignment requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm the required output resolution and controller interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume compatibility across all Renishaw readhead families. Confirm the exact readhead and scale combination using the relevant technical manual.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06. Installation Quality | Mechanical Preparation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eScale installation directly affects measurement accuracy. Follow a controlled preparation and alignment procedure. \u003cstrong\u003eBefore Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the steel strip for scratches and deformation.\u003c\/li\u003e\n\u003cli\u003eCheck the mounting surface for dust and oil.\u003c\/li\u003e\n\u003cli\u003eConfirm the required scale length and measurement travel.\u003c\/li\u003e\n\u003cli\u003eVerify the mounting surface material and condition.\u003c\/li\u003e\n\u003cli\u003ePrepare compatible end clamps and epoxy adhesive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a straight scale alignment along the travel axis.\u003c\/li\u003e\n\u003cli\u003eAvoid twisting or stretching the flexible steel strip.\u003c\/li\u003e\n\u003cli\u003ePrevent trapped particles beneath the adhesive backing.\u003c\/li\u003e\n\u003cli\u003eSecure the scale ends according to installation instructions.\u003c\/li\u003e\n\u003cli\u003eAllow the adhesive to cure before final measurement checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the scale surface for visible damage.\u003c\/li\u003e\n\u003cli\u003eVerify readhead alignment across the full travel range.\u003c\/li\u003e\n\u003cli\u003eCheck incremental signal stability during axis movement.\u003c\/li\u003e\n\u003cli\u003eConfirm reference positioning and controller feedback.\u003c\/li\u003e\n\u003cli\u003eRecord the installation conditions for future maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e07. Surface Care | Cleaning and Maintenance Protocol\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe protective lacquer requires careful handling. Incorrect solvents can damage the optical surface. \u003cstrong\u003eRecommended Cleaning Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRenishaw-approved cleaning wipes.\u003c\/li\u003e\n\u003cli\u003eIsopropyl alcohol (propan-2-ol).\u003c\/li\u003e\n\u003cli\u003en-Heptane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProhibited Cleaning Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAcetone.\u003c\/li\u003e\n\u003cli\u003eChlorinated solvents.\u003c\/li\u003e\n\u003cli\u003eMethylated spirits (industrial denatured alcohol).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Procedure\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInspect the scale before cleaning.\u003c\/li\u003e\n\u003cli\u003eRemove loose particles using an approved method.\u003c\/li\u003e\n\u003cli\u003eApply the recommended cleaning solvent to a suitable wipe.\u003c\/li\u003e\n\u003cli\u003eClean carefully without scratching the optical surface.\u003c\/li\u003e\n\u003cli\u003eAllow the surface to dry before operating the readhead.\u003c\/li\u003e\n\u003cli\u003eInspect the scale for coating damage or adhesive separation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Warning:\u003c\/strong\u003e Never use aggressive solvents or abrasive tools. They can damage the protective lacquer and affect optical signal quality.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08. Industrial Applications | Motion and Metrology\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCNC Machinery:\u003c\/strong\u003e Linear axis position feedback and precision travel measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoordinate Measuring Machines:\u003c\/strong\u003e Position sensing for precision measurement axes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Metrology:\u003c\/strong\u003e Linear displacement measurement in inspection equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e Precision positioning in automated machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Incremental position feedback for linear motion systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Machine Tools:\u003c\/strong\u003e Scale integration on metal and composite machine structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e09. Procurement Information | Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS20-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eReflective Incremental Optical Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Carriers\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS and DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Confirmation\u003c\/td\u003e\n\u003ctd\u003eSubject to order requirements and stock availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e A 12-month warranty applies to covered product defects under the applicable sales terms. Contact our sales team for warranty coverage and claim procedures. \u003cstrong\u003eInternational Shipping:\u003c\/strong\u003e FedEx, UPS and DHL services are available. Delivery arrangements depend on destination, product availability and order confirmation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10. Engineering FAQ | Selection and Application Guidance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should the required scale length be calculated for a linear axis?\u003c\/strong\u003e Measure the complete working travel first. Then consider readhead movement, reference positioning and end-fixing space. Allow sufficient installation clearance at both ends. Select a scale length that covers the complete mechanical arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What causes measurement drift after a machine reaches operating temperature?\u003c\/strong\u003e Thermal gradients can affect the machine structure and measurement axis. Check substrate temperature distribution and mounting stability first. Also inspect the end clamps and bonding condition. Uneven heating can create errors even with a correctly selected scale.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can engineers install this flexible scale on a granite machine base?\u003c\/strong\u003e Yes, granite is among the stated compatible substrate materials. However, surface preparation and adhesive selection remain important. Verify the bonding procedure and end-fixing method before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should be checked if the optical signal becomes weak after cleaning?\u003c\/strong\u003e Inspect the protective lacquer for scratches or chemical damage. Check for solvent residue and remaining contamination. Then verify readhead alignment and optical clearance. Replace damaged scale sections when the optical surface no longer meets application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Should buyers select the scale by length alone?\u003c\/strong\u003e No. Confirm the 20 µm pitch and compatible RGH readhead first. Then evaluate scale length, substrate material, operating temperature and installation geometry. Also check the required linearity and machine travel before confirming the order.\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155387773110,"sku":"RGS20-S","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGS20-S-3.jpg?v=1795577737","url":"https:\/\/www.plcsparehub.com\/ar\/products\/rgs20-s-renishaw-incremental-optical-scale-quantic-rgh-systems","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}