{"product_id":"renishaw-rgh22b50l00a-linear-optical-encoder-readhead","title":"Renishaw RGH22B50L00A Linear Optical Encoder Readhead","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #e87516;\"\u003eRenishaw RGH22B50L00A\u003c\/strong\u003e is a non-contact optical linear encoder readhead. It belongs to the \u003cstrong style=\"color: #e87516;\"\u003eRGH22 series\u003c\/strong\u003e within the RG2 incremental encoder system.\u003c\/p\u003e\n\u003cp\u003eThis readhead provides \u003cstrong\u003e1 Vpp differential analogue output\u003c\/strong\u003e for precision linear position feedback. It operates with the \u003cstrong\u003e20 µm pitch RGS20-S reflective steel scale\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe RGH22B configuration includes a single limit sensor and an integrated reference mark sensor. Its open optical design supports non-contact position measurement without mechanical contact with the scale.\u003c\/p\u003e\n\u003cp\u003eThe integrated set-up LED helps engineers check installation alignment. Internal signal interpolation supports stable position feedback in motion control applications.\u003c\/p\u003e\n\u003cp\u003eThe 5 m cable and 15-way D-type connector simplify integration with compatible controller interfaces. The standard 00A configuration provides the specified factory connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical measurement:\u003c\/strong\u003e Non-contact incremental linear position detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal output:\u003c\/strong\u003e 1 Vpp differential analogue signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale compatibility:\u003c\/strong\u003e 20 µm pitch RGS20-S reflective steel scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit detection:\u003c\/strong\u003e Integrated single limit sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference positioning:\u003c\/strong\u003e Integrated reference mark detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation support:\u003c\/strong\u003e Built-in multicolour set-up LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable assembly:\u003c\/strong\u003e 5 m, 12-core, double-shielded cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 15-way D-type plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGH22B50L00A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eRGH22 \/ RG2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOpen Optical Linear Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical incremental measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e1 Vpp differential analogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRGS20-S reflective steel tape scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e20 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle limit sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Mark\u003c\/td\u003e\n\u003ctd\u003eIntegrated reference mark sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e12-core, double-shielded, high-flexibility cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e4.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e15-way D-type plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e00A Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA, unterminated readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Termination Current\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 mA with 120 Ω analogue termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analogue Readhead Speed\u003c\/td\u003e\n\u003ctd\u003e4 m\/s at −3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide Height\u003c\/td\u003e\n\u003ctd\u003e0.8 ±0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Acceleration\u003c\/td\u003e\n\u003ctd\u003e500 m\/s², three axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e100 m\/s² maximum, 55 Hz to 2000 Hz, three axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating Shock\u003c\/td\u003e\n\u003ctd\u003e1000 m\/s², 6 ms, half-sine, three axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Weight\u003c\/td\u003e\n\u003ctd\u003e45 g, excluding cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring range:\u003c\/strong\u003e The scale determines the available measuring length. RGS20-S supports lengths up to 50 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal period:\u003c\/strong\u003e The analogue signal corresponds to the 20 µm scale pitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum speed:\u003c\/strong\u003e The RGH22A\/B analogue range supports up to 4 m\/s at −3 dB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale linearity:\u003c\/strong\u003e RGS20-S provides ±3 µm\/m scale linearity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e The analogue output does not specify one fixed digital resolution. The receiving controller determines interpolation resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e The manufacturer specifies 1 Vpp differential output rather than a separate sensitivity value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency response:\u003c\/strong\u003e The manufacturer specifies maximum analogue speed at −3 dB. Confirm controller bandwidth before system design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect mechanical alignment directly affects signal quality and measurement stability.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the machine uses the compatible \u003cstrong\u003eRGS20-S 20 µm scale\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eClean the mounting surface before installing the scale.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified scale alignment with the machine travel axis.\u003c\/li\u003e\n\u003cli\u003eMount the readhead using the designated fixing holes.\u003c\/li\u003e\n\u003cli\u003eSet the readhead ride height to \u003cstrong\u003e0.8 ±0.1 mm\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCheck the pitch and roll alignment against the installation drawing.\u003c\/li\u003e\n\u003cli\u003ePosition the reference mark actuator correctly along the measuring axis.\u003c\/li\u003e\n\u003cli\u003ePosition the single limit actuator within its specified sensing area.\u003c\/li\u003e\n\u003cli\u003eUse the integrated set-up LED to check optical alignment.\u003c\/li\u003e\n\u003cli\u003eConnect the 15-way D-type plug to the compatible receiving interface.\u003c\/li\u003e\n\u003cli\u003eVerify the 5 V DC supply before enabling machine movement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eMaintain the cable bend radius during installation. Follow the manufacturer's dynamic and static bend requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower verification:\u003c\/strong\u003e Check the 5 V DC supply and voltage stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal verification:\u003c\/strong\u003e Measure both differential analogue signal pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal balance:\u003c\/strong\u003e Check signal amplitude and waveform quality during axis movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference testing:\u003c\/strong\u003e Confirm repeatable reference mark detection in the intended travel direction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit testing:\u003c\/strong\u003e Verify the single limit output with its actuator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlignment inspection:\u003c\/strong\u003e Check the set-up LED and specified ride height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding inspection:\u003c\/strong\u003e Verify the inner and outer shield connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical inspection:\u003c\/strong\u003e Check scale adhesion, contamination and cable condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor electrical noise control, follow Renishaw's grounding arrangement. Connect the outer shield to machine earth. Connect the inner shield to 0 V. Keep both shields electrically isolated.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRGH22B50L00A\u003c\/strong\u003e requires a compatible RGS20-S optical scale. The receiving controller must support 1 Vpp differential analogue inputs.\u003c\/p\u003e\n\u003cp\u003eEngineers should verify the connector pinout, supply voltage and signal termination before installation.\u003c\/p\u003e\n\u003cp\u003eTypical application areas include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCoordinate measuring and dimensional inspection machines.\u003c\/li\u003e\n\u003cli\u003ePrecision linear positioning systems.\u003c\/li\u003e\n\u003cli\u003eSemiconductor and electronics manufacturing equipment.\u003c\/li\u003e\n\u003cli\u003eFlat panel display production equipment.\u003c\/li\u003e\n\u003cli\u003eAutomated inspection and measurement systems.\u003c\/li\u003e\n\u003cli\u003eLinear motor positioning platforms.\u003c\/li\u003e\n\u003cli\u003eElectronics assembly and testing equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility note:\u003c\/strong\u003e Do not treat digital RS422 RGH22 variants as direct electrical replacements. Their output interfaces differ from the RGH22B analogue configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Resistance and Signal Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGH22 readhead uses a double-shielded cable to support signal integrity. Its open optical design requires suitable protection from external contamination.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress protection:\u003c\/strong\u003e IP50 protects against dust ingress at the specified test level. It does not provide water protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical noise:\u003c\/strong\u003e Correct grounding and shield separation help reduce interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e The readhead supports the specified operating vibration conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical shock:\u003c\/strong\u003e The datasheet specifies a non-operating shock limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Maintain the readhead within its rated operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGH22 technical datasheet specifies electrical, environmental and mechanical operating limits.\u003c\/p\u003e\n\u003cp\u003eIt also references a 5 V DC supply compliant with SELV requirements under IEC BS EN 60950-1.\u003c\/p\u003e\n\u003cp\u003eSpecific product certification documents are not confirmed by the available model information. Please request applicable declarations and certificates when required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Renishaw RGH22B50L00A optical encoder readhead.\u003c\/li\u003e\n\u003cli\u003e1 × Integrated 5 m double-shielded cable.\u003c\/li\u003e\n\u003cli\u003e1 × 15-way D-type connector.\u003c\/li\u003e\n\u003cli\u003eProduct identification and applicable documentation, subject to supply scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The RGS20-S scale and mounting accessories are separate items unless the quotation explicitly includes them. Confirm the delivery scope before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which scale works with the RGH22B50L00A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe compatible scale is the Renishaw RGS20-S reflective steel tape scale. It uses a 20 µm pitch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the RGH22B50L00A provide digital RS422 output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This model provides 1 Vpp differential analogue output. Select a digital RGH22 variant for RS422 signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the readhead operate without an RGS20-S scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The optical readhead requires a compatible scale for incremental position measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why does the analogue signal become unstable after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst inspect ride height, optical alignment and scale cleanliness. Then check the 5 V supply, grounding and cable shielding. Incorrect termination can also affect waveform quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should engineers check when replacing an existing RGH22 readhead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete part number, output type, cable length and connector. Also verify the limit configuration and reference mark operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Can a controller accept the RGH22B output directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly if its input supports compatible 1 Vpp differential analogue signals. Check input impedance, bandwidth and signal conditioning requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: Does the 20 µm scale pitch represent the final positioning resolution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The controller determines the final interpolated resolution. Check its interpolation capability and input specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Does the 5 m cable support long-distance signal transmission?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated cable measures 5 m. The manufacturer permits longer extension arrangements under specified shielding and wiring conditions. Consult the RGH22 installation documentation before extending the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: What information should buyers confirm before ordering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the complete model number, connector, cable length and scale compatibility. Also check the controller input type and required mounting accessories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: Is the RGS20-S scale included with this readhead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. The readhead and scale form separate system components. Confirm the quotation and packing list before purchase.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155195031734,"sku":"RGH22B50L00A","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22B50L00A-3.jpg?v=1795576581","url":"https:\/\/www.plcsparehub.com\/ar\/products\/renishaw-rgh22b50l00a-linear-optical-encoder-readhead","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}