{"product_id":"q4bcy30d10a-renishaw-quantic-incremental-optical-encoder-readhead","title":"Q4BCY30D10A Renishaw QUANTiC Incremental Optical Encoder Readhead","description":"\u003ch3\u003e\u003cb\u003e01 | Product Identity – Optical Feedback Technology\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #167a65;\"\u003eRenishaw Q4BCY30D10A\u003c\/span\u003e\u003c\/strong\u003e is a QUANTiC™ incremental optical encoder readhead for precision linear motion systems. It reads an optical scale and generates incremental position feedback for motion controllers. Its 40 µm scale pitch supports accurate position measurement in industrial automation equipment. The readhead integrates optical signal processing and automatic signal adjustment functions. Its compact design supports machine integration where positioning accuracy and installation flexibility matter. Key identification:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Renishaw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eQ4BCY30D10A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e QUANTiC™\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Incremental Optical Encoder Readhead\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Configuration:\u003c\/strong\u003e Linear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Pitch:\u003c\/strong\u003e 40 µm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Resolution:\u003c\/strong\u003e 0.1 µm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Configuration:\u003c\/strong\u003e Customer-selectable reference mark and limit sensor arrangement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e02 | Configuration Breakdown – Decode Every Suffix\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete order code identifies the readhead configuration and electrical interface. The following table follows the supplied model-code interpretation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eEngineering Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQ4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eQUANTiC™ series, 40 µm scale pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eLinear encoder configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReadhead Version\u003c\/td\u003e\n\u003ctd\u003eStandard readhead with integrated setup LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µm digital resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type connector (DB15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReference \/ Limit Configuration\u003c\/td\u003e\n\u003ctd\u003eCustomer-selectable reference mark and dual-limit sensor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cblockquote\u003eQ4 → 40 µm QUANTiC™ platform B → Linear measurement system C → Standard readhead with setup LED Y → 0.1 µm digital resolution 30 → 3.0 m cable D → 15-pin D-type connector 10 → 10 MHz clock frequency A → Reference and limit sensor configuration\u003c\/blockquote\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Selection Note:\u003c\/strong\u003e Confirm the complete suffix against the official Renishaw ordering documentation. Verify the required reference and limit functions before placing an order.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Optical Performance – Position Feedback Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Technology\u003c\/td\u003e\n\u003ctd\u003eIncremental optical sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Direction\u003c\/td\u003e\n\u003ctd\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µm (100 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Series Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 24 m\/s, subject to resolution and clock configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Height Tolerance\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngular Installation Tolerance\u003c\/td\u003e\n\u003ctd\u003e±0.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Adjustment\u003c\/td\u003e\n\u003ctd\u003eAGC, ABC and AOC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup Indicator\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Interpretation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 nm Resolution:\u003c\/strong\u003e Provides fine digital position increments for precision motion feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz Clock:\u003c\/strong\u003e Defines an important part of the digital interface and maximum speed capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 m\/s Series Capability:\u003c\/strong\u003e Represents the stated QUANTiC family maximum, not a guaranteed speed at every resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Tolerance:\u003c\/strong\u003e Reduces sensitivity to minor mounting variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conditioning:\u003c\/strong\u003e Helps maintain stable optical feedback during normal operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Resolution represents the digital measurement increment. It does not independently define system accuracy, repeatability or measurement uncertainty.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Intelligent Signal Control – AGC, ABC and AOC\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe QUANTiC™ readhead integrates three automatic signal adjustment functions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnology\u003c\/th\u003e\n\u003cth\u003eEngineering Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAGC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Gain Control adjusts signal amplitude.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Balance Control maintains signal balance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAOC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Offset Control compensates for signal offset.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese functions help maintain usable optical signals under changing operating conditions. They also reduce sensitivity to minor optical contamination and signal variations. However, they do not eliminate the need for scale cleaning and correct mechanical alignment.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Mechanical Integration and Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Linear Scale Families:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRTLC40\u003c\/li\u003e\n\u003cli\u003eRTLC40-S\u003c\/li\u003e\n\u003cli\u003eRKLC40-S\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the scale model and 40 µm pitch compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect the mounting surface for contamination and mechanical damage.\u003c\/li\u003e\n\u003cli\u003ePosition the readhead according to the applicable installation drawing.\u003c\/li\u003e\n\u003cli\u003eSet the required readhead-to-scale installation height.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified ±0.3 mm height tolerance.\u003c\/li\u003e\n\u003cli\u003eCheck angular alignment within the specified ±0.9° tolerance.\u003c\/li\u003e\n\u003cli\u003eConnect the 15-pin interface to the compatible controller.\u003c\/li\u003e\n\u003cli\u003eProvide a stable 5 V DC supply.\u003c\/li\u003e\n\u003cli\u003eUse the integrated LED to assist setup and alignment checks.\u003c\/li\u003e\n\u003cli\u003eMove the axis slowly and verify stable position feedback.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Recommendation:\u003c\/strong\u003e Avoid excessive cable bending and mechanical stress at the connector. Secure the cable away from motor power cables and high-frequency switching sources.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Controller Integration and Electrical Considerations\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eQ4BCY30D10A\u003c\/strong\u003e provides incremental digital position feedback. Before connecting it to a motion controller, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Compatibility:\u003c\/strong\u003e The controller must provide the specified 5 V DC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Compatibility:\u003c\/strong\u003e Confirm the 15-pin D-type interface and pin assignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e Verify the controller accepts the readhead's output signal format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Compatibility:\u003c\/strong\u003e Check the 10 MHz interface configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution Settings:\u003c\/strong\u003e Configure the controller for 0.1 µm resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Processing:\u003c\/strong\u003e Confirm the controller supports the selected reference mark arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit Inputs:\u003c\/strong\u003e Verify the required limit sensor functions and input assignments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not connect the readhead based on connector shape alone. Confirm the electrical interface and pinout before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Maintenance and Diagnostic Recommendations\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Condition\u003c\/th\u003e\n\u003cth\u003eRecommended Inspection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable position feedback\u003c\/td\u003e\n\u003ctd\u003eInspect optical surfaces, alignment and cable connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference position failure\u003c\/td\u003e\n\u003ctd\u003eCheck reference mark configuration and controller settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent signal loss\u003c\/td\u003e\n\u003ctd\u003eInspect cable routing, connector contacts and supply stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected position counts\u003c\/td\u003e\n\u003ctd\u003eVerify resolution settings and controller signal compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup LED indicates an issue\u003c\/td\u003e\n\u003ctd\u003eFollow the applicable Renishaw setup and diagnostic instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Practice:\u003c\/strong\u003e Keep the optical scale clean and inspect the cable periodically. Avoid abrasive cleaning materials and excessive mechanical force.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Application Areas\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCNC Machine Tools:\u003c\/strong\u003e Linear axis position feedback and motion control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Automation:\u003c\/strong\u003e Position monitoring in automated production equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Equipment:\u003c\/strong\u003e High-resolution linear positioning applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetrology Systems:\u003c\/strong\u003e Position feedback for precision measurement platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobotics:\u003c\/strong\u003e Linear actuator and positioning mechanism feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Motion Systems:\u003c\/strong\u003e Closed-loop position control and axis monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e09 | Purchasing, Warranty and Delivery\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRenishaw QUANTiC™ Optical Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ4BCY30D10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 µm pitch \/ 0.1 µm resolution \/ 3.0 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx \/ UPS \/ DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Verification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel number and configuration confirmation before dispatch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Includes a 12-month warranty against covered product defects under the applicable sales terms. Contact our sales team for warranty conditions and claim procedures. \u003cstrong\u003eShipping:\u003c\/strong\u003e International delivery options include FedEx, UPS and DHL. Dispatch arrangements depend on stock status and order confirmation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Technical FAQ – Selection and Engineering Experience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should engineers select the correct scale for this readhead?\u003c\/strong\u003e Start with the 40 µm scale pitch requirement. Then check the mechanical mounting arrangement, scale length and operating environment. Confirm compatibility with RTLC40, RTLC40-S or RKLC40-S before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does 0.1 µm resolution mean the machine achieves 0.1 µm positioning accuracy?\u003c\/strong\u003e No. Resolution describes the smallest digital position increment. Actual positioning accuracy also depends on scale accuracy, mechanical stiffness, thermal expansion, controller performance and installation quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should be checked when the encoder works at low speed but fails at high speed?\u003c\/strong\u003e Check the controller input frequency limit first. Then verify the selected resolution, clock configuration and signal integrity. Excessive cable interference or an incompatible receiver can also affect high-speed operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is a 3-meter cable suitable for every machine installation?\u003c\/strong\u003e Not necessarily. Measure the complete cable route before ordering. Include cable routing, connector access and maintenance clearance. Avoid unnecessary extensions or unverified cable modifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers confirm before purchasing Q4BCY30D10A?\u003c\/strong\u003e Confirm the 40 µm scale pitch, linear configuration, 0.1 µm resolution and 3-meter cable. Also verify the DB15 interface, controller compatibility and reference or limit requirements. Compare the complete ordering code with the installed readhead to avoid configuration mismatches.\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155278327990,"sku":"Q4BCY30D10A","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22Y30D61A-3_f5212f7c-7e7e-43b9-8558-e1ff63ce867e.jpg?v=1795576951","url":"https:\/\/www.plcsparehub.com\/ar\/products\/q4bcy30d10a-renishaw-quantic-incremental-optical-encoder-readhead","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}