{"product_id":"igt247-ifm-full-metal-sensor-m18-5-mm-pnp-normally-open-proximity-switch","title":"IGT247 IFM Full-Metal Sensor | M18 5 mm PNP Normally Open Proximity Switch","description":"\u003ch3\u003e\u003cb\u003eIGT247 | IFM Inductive Full-Metal Proximity Sensor\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIFM IGT247\u003c\/strong\u003e is an M18 inductive proximity sensor designed for non-contact detection of metal targets in industrial environments exposed to frequent washdown and aggressive cleaning agents. Its full-metal construction uses 316L stainless steel (1.4404) for the housing and sensing face, while IP68 and IP69K protection support demanding cleaning and moisture-exposure conditions.\u003c\/p\u003e\n\u003cp\u003eThe sensor uses a 5 mm nominal sensing range, a PNP normally open switching output, and a 10–30 V DC supply. Gold-plated M12 connector contacts provide the specified electrical interface. With a listed pressure rating of 100 bar at the sensing face and an operating temperature range of 0 to 100 °C, the device is intended for applications where mechanical durability, hygienic cleaning routines, and reliable metal detection are important.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel identification note:\u003c\/strong\u003e The supplied product information identifies the type designation as \u003cstrong\u003eIGK3005-BPKG\/AM\/US-104\u003c\/strong\u003e and the document\/model reference as \u003cstrong\u003eIGT247-01\u003c\/strong\u003e. Verify the exact ordering code on the product label and manufacturer documentation before purchasing. This page uses IGT247 as the requested product reference.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | The Engineering Snapshot\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct reference\u003c\/td\u003e\n\u003ctd\u003eIGT247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied type designation\u003c\/td\u003e\n\u003ctd\u003eIGK3005-BPKG\/AM\/US-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003eInductive full-metal proximity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing style\u003c\/td\u003e\n\u003ctd\u003eThreaded, M18 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal sensing range\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating distance\u003c\/td\u003e\n\u003ctd\u003e0–4.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput configuration\u003c\/td\u003e\n\u003ctd\u003ePNP, normally open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e10–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage drop\u003c\/td\u003e\n\u003ctd\u003e2.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP68, IP69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient operating temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing and sensing face\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel (1.4404)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003e1 × M12 connector, gold-plated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus indication\u003c\/td\u003e\n\u003ctd\u003eFour yellow LEDs, spaced at 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 55 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e02 | Designed for Aggressive Cleaning Environments\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe full-metal construction is a key selection factor for machinery exposed to regular cleaning. Stainless steel 316L is used for the housing and sensing face, while the listed IP68 and IP69K ratings address protection against water ingress under their applicable test conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequent washdown:\u003c\/strong\u003e Suitable for evaluation in production areas where equipment is regularly cleaned with water or approved cleaning agents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant construction:\u003c\/strong\u003e The 316L stainless-steel surfaces are intended for demanding industrial environments. Actual chemical compatibility still depends on the cleaning agent, concentration, temperature, and exposure duration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure-resistant sensing face:\u003c\/strong\u003e The specified 100 bar pressure rating applies to the sensing face, not automatically to the entire sensor assembly, connector, cable, or installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-direction status indication:\u003c\/strong\u003e Four yellow LEDs positioned at 90° intervals improve visibility of the switching state from different viewing angles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold-plated contacts:\u003c\/strong\u003e The M12 connection uses gold-plated contacts as specified, helping provide the intended connector interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIP69K does not mean unlimited resistance to every chemical or cleaning procedure. Confirm compatibility with the actual washdown chemicals and the connector\/cable assembly, and follow the manufacturer's mounting and cleaning instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Detection Performance and Target-Material Effects\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe nominal sensing range is 5 mm, with a listed operating distance of 0–4.05 mm. The actual switching point depends on target material, target geometry, mounting conditions, and installation tolerances. The supplied correction factors show why target composition matters when setting a detection gap.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget material\u003c\/th\u003e\n\u003cth\u003eCorrection factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe listed hysteresis is 1–20% of the nominal sensing range (Sr). For reliable commissioning, test the actual target material and dimensions rather than assuming that every metal object will be detected at 5 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePractical setup:\u003c\/strong\u003e Start within the specified operating distance, confirm repeatable switching as the target approaches and moves away, and then establish a margin for vibration, mechanical tolerances, and target variation. Copper targets in particular may require a much shorter gap than steel because the listed correction factor is lower.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Electrical Interface and Output Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical feature\u003c\/th\u003e\n\u003cth\u003eEngineering implication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePNP normally open output\u003c\/td\u003e\n\u003ctd\u003eThe output switches positive supply potential to a compatible input or load when the sensor detects a target.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply range: 10–30 V DC\u003c\/td\u003e\n\u003ctd\u003eConfirm the supply remains within range during startup and switching.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current: 100 mA\u003c\/td\u003e\n\u003ctd\u003eKeep the connected load within the rated output current. Use an interface relay or suitable driver for higher-current loads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage drop: 2.5 V DC\u003c\/td\u003e\n\u003ctd\u003eAccount for the voltage drop when checking the voltage available to the receiving input or load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003ePulsed short-circuit protection is specified. Remove the fault rather than repeatedly relying on the protection circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003eProtection is specified; confirm detailed behavior in the manufacturer's documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse-polarity protection\u003c\/td\u003e\n\u003ctd\u003eSpecified as present, but correct polarity and wiring remain necessary for normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency: 100 Hz\u003c\/td\u003e\n\u003ctd\u003eCheck that target passage frequency and required response remain within the sensor's specified switching capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBefore connecting the sensor to a PLC, verify that the receiving input supports PNP switching and that the common wiring is correct. Do not connect the sensor output directly to a load that exceeds its current rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Where the IGT247 Can Be Applied\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage machinery:\u003c\/strong\u003e Detecting metal machine components or product-handling mechanisms in areas subject to routine washdown, where the installation and material compatibility requirements are met.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical and personal-care equipment:\u003c\/strong\u003e Position and presence detection on compatible stainless-steel machinery exposed to frequent cleaning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging lines:\u003c\/strong\u003e Detecting metal carriers, mechanical stops, indexing parts, and moving machine elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilling and conveying systems:\u003c\/strong\u003e Confirming the position of actuators, fixtures, and metal components in wet production environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process equipment:\u003c\/strong\u003e Non-contact position detection in installations where stainless-steel construction and moisture protection are important.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are representative applications for a full-metal inductive sensor. The sensor detects suitable metal targets; it is not a general-purpose detector for plastic, glass, or other non-metallic objects. Confirm that the required sensing distance and target material are suitable before specifying it.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Mechanical Installation and Commissioning\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the ordering code.\u003c\/strong\u003e Compare the product label with the purchasing specification, especially because the supplied information lists both IGT247 and IGK3005-BPKG\/AM\/US-104.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck mounting clearance.\u003c\/strong\u003e Verify the M18 × 1 threaded mounting dimensions, 70 mm overall length, and flush-mounting conditions against the machine design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply the specified tightening torque.\u003c\/strong\u003e The supplied value is 50 Nm. Confirm that this value applies to the intended mounting arrangement and follow the manufacturer's instructions to avoid damaging the sensor or mounting surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the M12 interface.\u003c\/strong\u003e Use a compatible connector and cable assembly rated for the environment. Verify pin assignment and supply polarity from the correct wiring diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the target gap.\u003c\/strong\u003e Adjust the sensor relative to the target material, accounting for the listed correction factor and expected mechanical movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest switching behavior.\u003c\/strong\u003e Move the target through the detection zone and confirm repeatable switching and LED indication. Test under representative operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the PLC input.\u003c\/strong\u003e Confirm that the PNP output is correctly recognized by the connected controller input and that the signal remains stable during machine operation and cleaning cycles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cb\u003e07 | Diagnostic Guide for Field Engineers\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe four yellow LEDs indicate switching status. The supplied data does not establish a dedicated onboard diagnostic interface that identifies every sensor or wiring fault, so troubleshooting should combine LED observation, electrical measurements, target checks, and PLC input status.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003eChecks to perform\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo switching LED when the target approaches\u003c\/td\u003e\n\u003ctd\u003eCheck the DC supply, M12 connector, pin assignment, target material, and sensing gap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED switches but PLC input remains OFF\u003c\/td\u003e\n\u003ctd\u003eVerify PNP\/NPN compatibility, input common wiring, output voltage, cable continuity, and PLC input configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFalse or intermittent switching\u003c\/td\u003e\n\u003ctd\u003eInspect mounting stability, target vibration, electrical interference, connector condition, and target material variation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection distance is shorter than expected\u003c\/td\u003e\n\u003ctd\u003eCheck the target's correction factor, dimensions, alignment, and mounting conditions. Stainless steel, aluminium, and copper have lower listed correction factors than steel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor stops operating after a wiring fault\u003c\/td\u003e\n\u003ctd\u003eRemove power safely, correct the short circuit or overload, and inspect the supply and output circuit before retesting. Protection does not guarantee immunity from every fault condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProblems appear after washdown\u003c\/td\u003e\n\u003ctd\u003eInspect the connector and mating cable, seals, mounting interface, and chemical compatibility. Confirm that the complete installed assembly meets the cleaning conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField diagnostic method:\u003c\/strong\u003e First confirm the supply voltage, then observe the LED response as a known metal target approaches, and finally measure the output and check the PLC input state. This sequence helps separate power, sensing, output-wiring, and controller-interface issues without unnecessary component replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Global PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen a proximity sensor is used in a washdown zone, selection should account for both the sensing task and the cleaning environment. A sensor may have an appropriate ingress-protection rating yet still require verification of chemical compatibility, connector sealing, and the pressure rating applicable to the sensing face.\u003c\/p\u003e\n\u003cp\u003eFor this model, engineers should pay particular attention to the target-material correction factor. A 5 mm nominal range does not guarantee the same operating distance for steel, stainless steel, aluminium, or copper. Confirm the real target material during commissioning and leave adequate distance margin for vibration and mechanical tolerance.\u003c\/p\u003e\n\u003cp\u003eBefore ordering a replacement, check the exact type designation, M18 × 1 mounting, M12 connector, PNP normally open output, and required sensing distance. Because the supplied information contains both an IGT247 reference and an IGK3005-BPKG\/AM\/US-104 type designation, matching the label to the intended part is especially important.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Product Condition, Warranty, and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct reference:\u003c\/strong\u003e IFM IGT247 inductive full-metal sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's warranty terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch estimate:\u003c\/strong\u003e Target dispatch within 24–48 hours after order confirmation, subject to stock availability, payment clearance, and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack quantity:\u003c\/strong\u003e 1 piece; the supplied specification lists two lock nuts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuotation support:\u003c\/strong\u003e Provide the exact type designation, required quantity, and delivery destination to request pricing and verify the correct variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e10 | Frequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Is the 5 mm sensing range guaranteed for stainless-steel targets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The nominal range is 5 mm, but the supplied correction factor for stainless steel is 0.7. Actual switching distance also depends on target dimensions, mounting, and installation tolerances. Validate the sensor against the real target rather than designing around the nominal figure alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. Can I connect the sensor directly to a PLC input designed for NPN sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot without verifying electrical compatibility. This sensor is specified as PNP, normally open. Check the PLC input type, common arrangement, and wiring diagram. If the input requires NPN signaling, an appropriate interface may be needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Does IP69K mean the sensor can withstand every cleaning chemical and pressure-washing procedure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. IP69K describes protection under defined ingress testing conditions; it does not establish universal chemical resistance or unlimited pressure tolerance. Confirm the cleaning chemical, temperature, exposure duration, connector sealing, and applicable pressure rating with the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. What should I inspect if the sensor works before cleaning but fails afterward?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the M12 connector and mating cable, seals, cable routing, mounting interface, and exposure to cleaning chemicals. Also verify supply voltage and output switching after the area is safe to access. Do not assume the sensing element has failed until the complete connection and installation have been inspected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. How do I verify that I am ordering the correct IFM variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete type designation printed on the label with the required part number, and confirm the output type, sensing range, thread size, connector, temperature range, and pressure requirements. The supplied data references both IGT247 and IGK3005-BPKG\/AM\/US-104, so request confirmation against the actual product label before placing the order.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Summary\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IFM IGT247 is described as a full-metal inductive proximity sensor with a 5 mm nominal sensing range, PNP normally open output, M18 × 1 threaded housing, M12 connection, and IP68\/IP69K protection. It is intended for metal-target detection in demanding industrial environments, including applications with frequent cleaning. Verify the exact ordering code, target-material effects, electrical interface, and installation conditions before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IGT247.png?v=1792141551\" alt=\"\"\u003e\u003c\/p\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":67651816947894,"sku":"IGT247","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IGT247.jpg?v=1792142325","url":"https:\/\/www.plcsparehub.com\/ar\/products\/igt247-ifm-full-metal-sensor-m18-5-mm-pnp-normally-open-proximity-switch","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}