{"product_id":"honeywell-xnx-amai-rnif1-universal-gas-transmitter-ir-propane","title":"Honeywell XNX-AMAI-RNIF1 Universal Gas Transmitter IR Propane","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIF1\u003c\/strong\u003e\u003c\/span\u003e operates as a high-performance industrial gas detector platform.\u003c\/p\u003e\n\u003cp\u003eThis \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e integrates seamless signal processing for combustible gas detection.\u003c\/p\u003e\n\u003cp\u003eEngineered with ATEX\/IEC explosion-proof certification, it features a heavy-duty painted aluminum housing.\u003c\/p\u003e\n\u003cp\u003eIt supports multi-bus communications and incorporates an infrared sensor tuned for 0-100% LEL propane detection.\u003c\/p\u003e\n\u003cp\u003eThe unit includes dedicated relay outputs for reliable industrial field alerts and safety shutoff control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur engineering team installed the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIF1\u003c\/strong\u003e\u003c\/span\u003e across multiple offshore hydrocarbon loading facilities.\u003c\/p\u003e\n\u003cp\u003eIn high-vibration compressor stations, standard gas transmitters often trigger false alarm trips.\u003c\/p\u003e\n\u003cp\u003eDuring a field project, the optical IR sensor maintained zero stability despite severe ambient moisture and fog.\u003c\/p\u003e\n\u003cp\u003eThe relay option provided instant local horn activation during emergency shutdown testing.\u003c\/p\u003e\n\u003cp\u003eWe recommend verifying terminal resistance during installation to ensure uninterrupted HART communication signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIF1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA = ATEX \/ IECEx Explosion-proof Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Entry Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM = M25 Threaded Cable Entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA = LM25 Marine-Grade Painted Aluminum Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePersonality Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI = Interface for Searchline Excel, Searchpoint Optima, and Generic 4-20mA inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Board Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR = Integrated Relay Board (3 Alarm\/Fault Relays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal HART Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN = No External Local HART Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type \u0026amp; Target Gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIF1 = Optical Infrared Hydrocarbon Sensor (0-100% LEL Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 100% LEL (Lower Explosive Limit) Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT90 \u0026lt; 4 seconds (Infrared Sensor Optical Channel Response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity \u0026amp; Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensitivity: ±1% LEL; Resolution: 1% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinearity deviation \u0026lt; ±2% FS across full operational scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +65°C (-40°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66 rating; corrosion-resistant marine epoxy finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnti-Interference Ability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmune to chemical poisoning, silicone contamination, and solar radiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg (9.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection \u0026amp; Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting your transmitter configuration, consider your system topology and HART setup requirement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIF1\u003c\/strong\u003e\u003c\/span\u003e: Features built-in relay contacts for direct local alarm control without extra local HART hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/xnx-amai-nhif1-honeywell-xnx-universal-gas-transmitter-in-stock\" target=\"_blank\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIF1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: Includes non-relay configuration designed for centralized safety systems without local output relays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Recommendation:\u003c\/strong\u003e Choose \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIF1\u003c\/strong\u003e\u003c\/span\u003e if local visual or audible beacon control is needed at the transmitter point.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Setup Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the enclosure securely to a structural wall or rigid pole structure.\u003c\/li\u003e\n\u003cli\u003eVerify that all M25 conduit entries utilize certified explosion-proof cable glands.\u003c\/li\u003e\n\u003cli\u003eConnect signal wiring according to standard 3-wire current loop power conventions.\u003c\/li\u003e\n\u003cli\u003eEnsure grounding straps bond the aluminum housing directly to plant ground grids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccess calibration settings magnetically through the toughened glass window cover.\u003c\/li\u003e\n\u003cli\u003ePerform non-intrusive target gas span checks without opening the enclosure.\u003c\/li\u003e\n\u003cli\u003eReview system health metrics using standard handheld HART communicators on signal lines.\u003c\/li\u003e\n\u003cli\u003eReplace modular internal circuit cards swiftly during field service procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirectly interfaces with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e Searchline Excel open path detectors.\u003c\/li\u003e\n\u003cli\u003eFully compatible with Searchpoint Optima Plus optical point gas detectors.\u003c\/li\u003e\n\u003cli\u003eIntegrates into standard 4-20mA DCS, PLC, and ESD safety control networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX Zone 1 and Zone 2 hazardous location compliance.\u003c\/li\u003e\n\u003cli\u003eIECEx international safety standard certification for hazardous explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003eSIL2 rating suitable for safety instrumented industrial system designs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIF1\u003c\/strong\u003e\u003c\/span\u003e Universal Transmitter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Factory Calibration Certificate and Quality Test Record\u003c\/li\u003e\n\u003cli\u003e1 x Quick Start Installation and Operating Manual\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12-Month Comprehensive Warranty Clause Included\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast Dispatch: Orders process and ship within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eGlobal Express Carriers: Shipped globally via FedEx, UPS, or DHL express services.\u003c\/li\u003e\n\u003cli\u003eProtective Packaging: Shipped in high-density anti-vibration industrial packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOnshore and offshore oil drilling rigs and production platforms.\u003c\/li\u003e\n\u003cli\u003eRefining units, chemical processing plants, and fuel storage facilities.\u003c\/li\u003e\n\u003cli\u003eGas turbine enclosure monitoring and pipeline compressor stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous monitoring of optical alignment and sensor window cleanliness.\u003c\/li\u003e\n\u003cli\u003eAutomatic fault reporting for internal hardware failures or power drops.\u003c\/li\u003e\n\u003cli\u003eBacklit graphical LCD display showing real-time status and concentration levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \u003cspan style=\"color: #0056b3;\"\u003eXNX-AMAI-RNIF1\u003c\/span\u003e require non-intrusive calibration in hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Technicians can calibrate the unit using magnetic switches through the glass front cover without opening the enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main advantage of the optical IR sensor over catalytic bead sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The optical IR sensor operates without oxygen and resists poisoning from silicones or hydrogen sulfide gases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the relay option (R) enhance local plant safety?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The relay module triggers local beacons or sirens instantly without waiting for DCS controller intervention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I interchange sensor personality cards inside the transmitter body?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The modular design accepts electrochemical, catalytic, or infrared sensor interface cards easily.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX_2.png?v=1787714324\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45386722771126,"sku":"XNX-AMAI-RNIF1","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NHNNN_3_77c40add-081b-4d6a-a989-c1d75e7c1c21.jpg?v=1787885442","url":"https:\/\/www.plcsparehub.com\/ar\/products\/honeywell-xnx-amai-rnif1-universal-gas-transmitter-ir-propane","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}