{"product_id":"honeywell-xnx-amai-nhiv1-gas-detector-universal-transmitter","title":"Honeywell XNX-AMAI-NHIV1 Gas Detector | Universal Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e provides advanced gas detection for harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eEngineers integrate this \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX Series\u003c\/strong\u003e\u003c\/span\u003e universal transmitter into safety systems seamlessly.\u003c\/p\u003e\n\u003cp\u003eIt supports infrared sensor technologies for continuous methane monitoring and toxic gas protection.\u003c\/p\u003e\n\u003cp\u003eThe rugged aluminium enclosure delivers reliable performance across demanding oil, gas, and chemical installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following table details core physical and operational parameters using the MECE framework:\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePersonality Type\u003c\/td\u003e\n\u003ctd\u003eInfrared product interface (Searchline Excel, Searchpoint Optima)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eSensing Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTarget Gas \u0026amp; Range\u003c\/td\u003e\n\u003ctd\u003eMethane (IR 0-100% LEL \/ 0-5% Vol.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity \u0026amp; Linearity\u003c\/td\u003e\n\u003ctd\u003eHigh accuracy within ±1% LEL full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eT90 \u0026lt; 10 seconds for rapid hazard detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eSignal \u0026amp; Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary Output\u003c\/td\u003e\n\u003ctd\u003e4-20mA analog current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Protocol\u003c\/td\u003e\n\u003ctd\u003eLocal HART handheld communicator support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePaint-coated Aluminium housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Entry Type\u003c\/td\u003e\n\u003ctd\u003eM25 thread conduit entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e4.4 kg (9.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eOperating Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +65°C operating threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIP66 ingress protection rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e transmitter on rigid walls or pipe stands directly.\u003c\/p\u003e\n\u003cp\u003eEnsure correct conduit orientation to prevent water accumulation inside the M25 enclosure entries.\u003c\/p\u003e\n\u003cp\u003eConnect field cabling to designated terminals according to standard 3-wire signal wiring diagrams.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance Convenience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOperators perform routine calibrations without opening the explosion-proof housing structure.\u003c\/p\u003e\n\u003cp\u003eUse local HART communicators or non-intrusive magnetic switches to configure all operational settings.\u003c\/p\u003e\n\u003cp\u003eBacklit LCD screens present real-time gas readings, status icons, and fault codes clearly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility Statement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e communicates directly with standard DCS and PLC control networks.\u003c\/p\u003e\n\u003cp\u003eIt interfaces with Searchpoint Optima Plus and Searchline Excel open-path infrared gas detectors.\u003c\/p\u003e\n\u003cp\u003eGeneric 4-20mA receiver cards accept signal inputs without requiring specialized interface adapters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eATEX and IECEx hazard zone approvals cover global offshore and onshore installations.\u003c\/p\u003e\n\u003cp\u003eCompliance ensures safe operation in Class I, Division 1 and Zone 1 explosive atmospheres.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List and Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX-AMAI-NHIV1 Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e assembly\u003c\/li\u003e\n\u003cli\u003e1 x Integral mounting hardware kit and cable glands\u003c\/li\u003e\n\u003cli\u003e1 x Factory calibration certificate and documentation card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Month Warranty:\u003c\/strong\u003e Includes full replacement coverage for hardware manufacturing defects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Delivery Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe process and dispatch orders within 24 to 48 hours from receipt.\u003c\/p\u003e\n\u003cp\u003eExpress courier options include FedEx, UPS, and DHL express international services.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOffshore oil drilling platforms and floating production storage vessels\u003c\/li\u003e\n\u003cli\u003ePetrochemical processing plants and hydrocarbon storage facilities\u003c\/li\u003e\n\u003cli\u003eGas turbine enclosure enclosures and compressor station facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Diagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal diagnostics continuously monitor optical path cleanliness and internal electronic circuit integrity.\u003c\/p\u003e\n\u003cp\u003eThe system flags optical obstruction and sensor fault codes immediately to minimize downtime.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection Guide and Model Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting your transmitter configuration, compare key features between these two \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX Series\u003c\/strong\u003e\u003c\/span\u003e units:\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/honeywell-xnx-amai-nniv1-xnx-universal-transmitter-gas-detector\"\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NNIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal HART Port\u003c\/td\u003e\n\u003ctd\u003eIntegrated Local HART interface port\u003c\/td\u003e\n\u003ctd\u003eNo local HART port installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Configuration\u003c\/td\u003e\n\u003ctd\u003eDirect HART handheld tool connection\u003c\/td\u003e\n\u003ctd\u003eMagnetic switch navigation only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Engineering Suitability\u003c\/td\u003e\n\u003ctd\u003eIdeal for complex field diagnostics\u003c\/td\u003e\n\u003ctd\u003eSuited for standardized automated setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Advice:\u003c\/strong\u003e Choose the \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e if field technicians require frequent HART handheld diagnostics at the sensor location.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur automation engineers frequently deploy \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX Series\u003c\/strong\u003e\u003c\/span\u003e transmitters in remote offshore installations.\u003c\/p\u003e\n\u003cp\u003eIn one LNG terminal project, ambient vibration caused signal noise on older analog units.\u003c\/p\u003e\n\u003cp\u003eUpgrading to the \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e resolved signal fluctuations due to its robust optical digital filtering.\u003c\/p\u003e\n\u003cp\u003eThe integrated local HART connection allowed field teams to verify calibration without opening junction boxes.\u003c\/p\u003e\n\u003cp\u003eThis feature saved technicians hours of maintenance time during critical safety audits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What primary gas does the Honeywell XNX-AMAI-NHIV1 monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: It measures Methane concentration from 0 to 100% LEL or 0 to 5% Volume using infrared optics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does local HART benefit plant technicians in field operations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Technicians connect HART handheld devices directly at the transmitter without breaking hazardous enclosure seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can field teams install this unit in hazardous industrial areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, ATEX and IECEx certifications permit installation in Zone 1 and Zone 2 hazardous areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What advantage does the aluminium housing provide over other materials?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The coated aluminium casing offers strong mechanical protection while keeping the total unit weight at 4.4 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX.png?v=1787714324\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45386720215222,"sku":"XNX-AMAI-NHIV1","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NHNNN_47a7b4cf-648c-41cc-913b-6bddbdc808ab.jpg?v=1787885246","url":"https:\/\/www.plcsparehub.com\/ar\/products\/honeywell-xnx-amai-nhiv1-gas-detector-universal-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}