{"product_id":"buy-tm3xtra1-schneider-modicon-tm3-remote-transmitter-module-request-quote","title":"Buy TM3XTRA1 Schneider Modicon TM3 Remote Transmitter Module - Request Quote","description":"\u003ch3\u003eSchneider Electric TM3XTRA1 Modicon TM3 Remote Transmitter Module\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cb\u003eTM3XTRA1\u003c\/b\u003e belongs to the advanced \u003cb\u003eModicon TM3\u003c\/b\u003e series. This remote transmitter module expands industrial control architectures. It connects remote expansion slices seamlessly. Engineers deploy this unit in modular automation systems. It maintains high signal integrity across distributed layouts. The device operates reliably in harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eTechnical Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand \u0026amp; Model\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric, \u003cb\u003eTM3XTRA1\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eModicon TM3\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModule Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transmitter module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCompatibility\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M241, M251, M221, M262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCurrent Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA at 5 V DC (on state); 30 mA at 5 V DC (off state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Power Dissipation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCable Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 5 meters via 2 RJ45 conductor extension cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical Connection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 connector, screw terminal for functional ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 55°C (horizontal), -10°C to 50°C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStorage Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRelative Humidity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDegree of Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions \u0026amp; Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eHeight 90 mm, Depth 73.3 mm, Width 23.65 mm, Weight 0.065 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental Tolerance \u0026amp; Immunity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eElectrostatic Discharge:\u003c\/b\u003e 8 kV air, 6 kV contact conforming to IEC 61000-4-2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectromagnetic Fields:\u003c\/b\u003e 10 V\/m (80 MHz to 1 GHz), 3 V\/m (1.4 GHz to 2 GHz), 1 V\/m (2 to 2.7 GHz) conforming to IEC 61000-4-3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConducted Disturbances:\u003c\/b\u003e 10 V (0.15 to 80 MHz) conforming to IEC 61000-4-6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVibration Resistance:\u003c\/b\u003e 3.5 mm at 5 to 8.4 Hz, 3 gn at 8.4 to 150 Hz on DIN rail or panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShock Resistance:\u003c\/b\u003e 15 gn for 11 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial Standards:\u003c\/b\u003e UL 508, CSA C22.2 No 142, IEC 61131-2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHazardous Locations:\u003c\/b\u003e Class I Division 2 Groups A, B, C, D; CSA C22.2 No 213; UL 1604.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMarine Approvals:\u003c\/b\u003e ABS, DNV, GL, Merchant Navy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDirectives \u0026amp; Marks:\u003c\/b\u003e CE, UKCA, RCM, C-Tick, GOST.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMounting Support:\u003c\/b\u003e Top hat TH35-15 and TH35-7.5 rails conforming to IEC 60715, or panel mounting via fixing kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGrounding Setup:\u003c\/b\u003e Connect the functional ground terminal securely to minimize noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCable Routing:\u003c\/b\u003e Keep RJ45 extension cables away from high-voltage power lines to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaintenance Routine:\u003c\/b\u003e Inspect local LED indicators regularly for power supply and link status verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities \u0026amp; Local Signalling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePower LED:\u003c\/b\u003e Solid green LED indicates active internal bus power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLink LED:\u003c\/b\u003e Green LED confirms stable data transmission between transmitter and receiver modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFault Isolation:\u003c\/b\u003e Rapid blinking states assist technicians in locating cable breaks or loose RJ45 connectors immediately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDistributed Control Panels:\u003c\/b\u003e Expanding I\/O capacity across separate enclosure cabinets within a manufacturing cell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging Machinery:\u003c\/b\u003e Linking remote sensor nodes to a central Modicon M241 or M251 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWater Treatment Plants:\u003c\/b\u003e Managing distant valve islands and flow transmitters from a primary control rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Expert Field Experience\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cb\u003eGlobal PLC Spare HUB Review:\u003c\/b\u003e When deploying the \u003cb\u003eTM3XTRA1\u003c\/b\u003e within the \u003cb\u003eModicon TM3\u003c\/b\u003e architecture, field engineers frequently encounter communication dropouts if unshielded RJ45 patch cords are used instead of specified industrial-grade extension cables. Always verify that the functional ground screw terminal is tied directly to the backplane earth bar. This simple step eliminates ground loops in high-vibration plant floors.\u003c\/blockquote\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eStandard Unit Package:\u003c\/b\u003e 1 x \u003cb\u003eTM3XTRA1\u003c\/b\u003e module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackage Dimensions:\u003c\/b\u003e 7.5 cm (H) x 12.5 cm (W) x 10.5 cm (L), Weight: 163.0 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFulfillment:\u003c\/b\u003e Dispatch within 24-48 hours via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Terms:\u003c\/b\u003e Comprehensive 12-month warranty included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e What is the maximum distance supported by the \u003cb\u003eTM3XTRA1\u003c\/b\u003e module?\u003cbr\u003e\u003cb\u003eAnswer:\u003c\/b\u003e The module supports cable distances between 0.5 and 5 meters using 2 RJ45 conductor extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e Can this module operate in vertical installations?\u003cbr\u003e\u003cb\u003eAnswer:\u003c\/b\u003e Yes, it supports vertical mounting with an ambient operating temperature range of -10°C to 50°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e Which controller series work with this remote transmitter?\u003cbr\u003e\u003cb\u003eAnswer:\u003c\/b\u003e It is fully compatible with Modicon M241, M251, M221, and M262 logic controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM3XTRA1.png?v=1789614815\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45463697785014,"sku":"TM3XTRA1","price":124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM3XTRA1-1.jpg?v=1789614717","url":"https:\/\/www.plcsparehub.com\/ar\/products\/buy-tm3xtra1-schneider-modicon-tm3-remote-transmitter-module-request-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}