{"product_id":"330103-00-03-90-12-05-bently-nevada-330103-3300-xl-probe-stock","title":"330103-00-03-90-12-05 Bently Nevada 330103 3300 XL Probe Stock","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003eBently Nevada 330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe provides precise eddy current measurement. Engineers use this \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e sensor to detect continuous shaft position and vibration. It delivers superior thermal stability and linear accuracy across demanding industrial environments. High-performance Polyphenylene Sulfide (PPS) seals the sensor tip against harsh process fluids.\u003c\/p\u003e\n\u003cp\u003eThis \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e 8mm sensor supports critical machinery monitoring. It outputs a clear negative DC voltage proportional to shaft distance. The robust design withstands extreme physical shock and high pressure differentials.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConfiguration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBase Model:\u003c\/b\u003e \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103\u003c\/b\u003e\u003c\/span\u003e - \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e 8 mm Probe, M10 x 1 thread, unarmored\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUnthreaded Length Option:\u003c\/b\u003e \u003cb\u003e00\u003c\/b\u003e - 0 mm unthreaded length\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOverall Case Length Option:\u003c\/b\u003e \u003cb\u003e03\u003c\/b\u003e - 30 mm case length\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTotal Length Option:\u003c\/b\u003e \u003cb\u003e90\u003c\/b\u003e - 9.0 meters (29.5 feet) integrated system cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnector \u0026amp; Cable Type Option:\u003c\/b\u003e \u003cb\u003e12\u003c\/b\u003e - ClickLoc miniature coaxial connector with FluidLoc cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAgency Approval Option:\u003c\/b\u003e \u003cb\u003e05\u003c\/b\u003e - CSA, ATEX, IECEx intrinsically safe \u0026amp; non-incendive ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSeries\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e 8mm Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils) total linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLinearity Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSensitivity \/ Scale Factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eVoltage Output Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-1 Vdc to -17 Vdc linear signal response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSub-micron level mechanical displacement detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFrequency Response\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz (DC) to 10 kHz (-3 dB cutoff point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe DC Resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9.87 ± 0.50 Ω (center conductor to outer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStandard Operating Temp\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eExtended Temp Capability\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to +218°C (+425°F) at tip for specialized runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEnvironmental Tolerance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e93% relative humidity per IEC 68-2-3 (56 days)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTip \u0026amp; Case Materials\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS) tip, 303\/304 Stainless Steel body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInternal Pressure Seal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral Viton O-ring seals differential pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Calibration Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe using its metric M10x1 thread interface. Ensure thread engagement does not exceed 15 mm. Tighten the probe body securely to prevent rotational looseness during operation.\u003c\/p\u003e\n\u003cp\u003eSet the initial gap distance to -9.0 Vdc. This voltage correlates to roughly 1.27 mm (50 mils) mechanical gap. Verify the gap reading using a calibrated digital multimeter at the Proximitor output.\u003c\/p\u003e\n\u003cp\u003eProtect the ClickLoc connector from moisture and contaminants. Always route field wiring via 3-conductor shielded triad cable. Connect the shield line strictly at the monitor end ground point.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility \u0026amp; Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe pairs with \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e Proximitor Sensors. It integrates directly into Bently Nevada 3500 and 3300 rack systems. The 9.0-meter probe connects to sensors without needing extra extension cables.\u003c\/p\u003e\n\u003cp\u003eUse correct field wiring up to 305 meters (1,000 feet). Proper cable selection guarantees zero high-frequency signal roll-off.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTarget Applications \u0026amp; Diagnostics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineers deploy the \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe on critical turbomachinery. It monitors radial shaft vibration, axial thrust position, and keyphasor timing. The probe delivers precise dynamic data for predictive maintenance programs.\u003c\/p\u003e\n\u003cp\u003eDiagnostic capabilities include identifying shaft unbalance, misalignments, and bearing wear. Early fault detection prevents sudden catastrophic machine failures.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eIn our engineering field tests, the \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe excels in wet oil environments. The FluidLoc cable construction prevents oil leaks through the inner cable jacket. This feature protects junction boxes from oil contamination over long operations.\u003c\/p\u003e\n\u003cp\u003eAvoid exposing the probe tip to temperatures under -34°C (-30°F). Low temperatures can cause premature failure of the internal Viton pressure seal. Always check cable continuity before final installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eModel Comparison \u0026amp; Selection Advice\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eCable Style\u003c\/th\u003e\n\u003cth\u003eSystem Length\u003c\/th\u003e\n\u003cth\u003eApplication Suitability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFluidLoc \/ Unarmored\u003c\/td\u003e\n\u003ctd\u003e9.0 Meters\u003c\/td\u003e\n\u003ctd\u003eBest for oil-sealed internal machine routings without conduit enclosures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330103-00-03-10-01-00-bently-nevada-3300-xl-probe-without-armor\"\u003e\u003cb\u003e330103-00-03-10-01-00\u003c\/b\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Cable \/ Unarmored\u003c\/td\u003e\n\u003ctd\u003e1.0 Meter\u003c\/td\u003e\n\u003ctd\u003eIdeal for short internal runs requiring external extension cables.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e330902-00-15-10-01-05\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored \/ NSV Style\u003c\/td\u003e\n\u003ctd\u003e1.0 Meter\u003c\/td\u003e\n\u003ctd\u003eDesigned for narrow installation spaces requiring heavy mechanical protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eSelection Tip:\u003c\/b\u003e Choose the 9.0-meter \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e model to eliminate cable connection joints inside bearing housings. Fewer cable connections significantly reduce potential signal failure points.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCertifications \u0026amp; Hazardous Area Approvals\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe holds global hazardous area approvals. Option 05 combines CSA, ATEX, and IECEx certifications for versatile global installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIntrinsically Safe (ia):\u003c\/b\u003e Class I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I, Div 1, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNon-Incendive (nA, ec):\u003c\/b\u003e Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eWarranty \u0026amp; Express Shipping Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB provides a comprehensive 12-month warranty on this probe. We guarantee full functional performance and hardware authenticity.\u003c\/p\u003e\n\u003cp\u003eOrders ship within 24 to 48 hours via fast global carriers. We offer express dispatch through FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ1: Can I connect the 9-meter cable probe directly to a Proximitor sensor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \u003cspan style=\"color: #003366;\"\u003e\u003cb\u003e330103-00-03-90-12-05\u003c\/b\u003e\u003c\/span\u003e probe features a 9.0-meter integrated cable. You must connect it directly to a 9.0-meter Proximitor sensor without extension cables.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ2: What makes the FluidLoc cable option necessary in turbomachinery?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc option prevents oil and liquids from leaking through the inner cable sheath. It stops hazardous process fluids from escaping past the probe boundary.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ3: How do I verify if my probe gap setting is correct during installation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the DC output voltage at the sensor. A reading of -9.0 Vdc confirms a correct gap setting of roughly 1.27 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ4: What happens if I shorten or trim the 9-meter probe cable manually?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNever trim or shorten the probe cable. Trimming alters internal resistance, which ruins system calibration and linear measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ5: How do I select between standard and extended temperature range probes?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eSelect standard probes for operating temperatures up to +177°C. Choose extended temperature models if tip exposure continuously exceeds +177°C.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45368525947062,"sku":"330103-00-03-90-12-05","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_1.jpg?v=1787107756","url":"https:\/\/www.plcsparehub.com\/ar\/products\/330103-00-03-90-12-05-bently-nevada-330103-3300-xl-probe-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}